• Title/Summary/Keyword: optimal threshold

Search Result 538, Processing Time 0.028 seconds

Low Frequency Noise and It's Psychological Effects

  • Eom, Jin-Sup;Kim, Sook-Hee;Jung, Sung-Soo;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • Objective: This entire study has two parts. Study I aimed to develop a psychological assessment scale and the study II aimed to investigate the effects of LFN (low frequency noise) on the psychological responses in humans, using the scale developed in the study I. Background: LFN is known to have a negative impact on the functioning of humans. The negative impact of LFN can be categorized into two major areas of functioning of humans, physiological and psychological areas of functioning. The physiological impact can cause abnormalities in threshold, balancing and/or vestibular system, cardiovascular system and, hormone changes. Psychological functioning includes cognition, communication, mental health, and annoyance. Method: 182 college students participated in the study I in development of a psychological assessment scale and 42 paid volunteers participated in the study II to measure psychological responses. The LFN stimuli consisted of 12 different pure tones and 12 different 1 octave-band white noises and each stimulus had 4 different frequencies and 3 different sounds pressure levels. Results: We developed the psychological assessment scale consisting of 17 items with 3 dimensions of psychological responses (i.e., perceived physical, perceived physiological, and emotional responses). The main findings of LFN on the responses were as follows: 1. Perceived psychological responses showed a linear relation with SPL (sound pressure level), that is the higher the SPL is, the higher the negative psychological responses were. 2. Psychological responses showed quadric relations with SPL in general. 3. More negative responses at 31.5Hz LFN than those of 63 and 125Hz were reported, which is deemed to be caused by perceived vibration by 31.5Hz. 'Perceived vibration' at 31.5Hz than those of other frequencies of LFN is deemed to have amplified the negative psychological response. Consequently there found different effects of low frequency noise with different frequencies and intensity (SPL) on multiple psychological responses. Conclusion: Three dimensions of psychological responses drawn in regard to this study differed from others in the frequencies and SLP of LFN. Negative psychological responses are deemed to be differently affected by the frequency, SPL of the LFN and 'feel vibration' induced by the LFN. Application: The psychological scale from our study can be applied in quantitative psychological measurement of LFN at home or industrial environment. In addition, it can also help design systems to block LFN to provide optimal conditions if used the study outcome, .i.e., the relations between physical and psychological responses of LFN.

Chromatic adaptation model for the variations of the luminance of the same chromaticity illuminants (동일 색도 광원의 휘도 변화에 따른 색 순응 모델)

  • Kim Eun-Su;Jang Soo-Wook;Lee Sung-Hak;Sohng Kyu-lk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.31-38
    • /
    • 2005
  • In this paper, we propose the chromatic adaptation models (CAM) for the variations of the luminance levels. A chromatic adaptation model, CAM$\Delta$Y , is proposed according to the change of luminance level under the same illuminants. The proposed model is obtained by the transform the test colors of the high luminance into the corresponding colors of the low luminance. In the proposed model, the optimal coefficients are obtained from the corresponding colors data of the Breneman's experiments. In the experimental results, we confined that the chromaticity errors, $\Delta$u'v', between the predicted colors by the proposed model and the corresponding colors of the Breneman's experiments are 0.004 in u'v' chromaticity coordinates. The prediction performance of the proposed model is excellent because this error is the threshold value that two adjacent color patches can be distinguished. Additionally, we also propose equal-whiteness CCT curves (EWCs) by CAM$\Delta$Y according to the luminance levels of the surround viewing conditions. And the proposed EWCs can be used as the theoretical standard which determines the reference white of the color display devices.

Fire Detection Approach using Robust Moving-Region Detection and Effective Texture Features of Fire (강인한 움직임 영역 검출과 화재의 효과적인 텍스처 특징을 이용한 화재 감지 방법)

  • Nguyen, Truc Kim Thi;Kang, Myeongsu;Kim, Cheol-Hong;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.6
    • /
    • pp.21-28
    • /
    • 2013
  • This paper proposes an effective fire detection approach that includes the following multiple heterogeneous algorithms: moving region detection using grey level histograms, color segmentation using fuzzy c-means clustering (FCM), feature extraction using a grey level co-occurrence matrix (GLCM), and fire classification using support vector machine (SVM). The proposed approach determines the optimal threshold values based on grey level histograms in order to detect moving regions, and then performs color segmentation in the CIE LAB color space by applying the FCM. These steps help to specify candidate regions of fire. We then extract features of fire using the GLCM and these features are used as inputs of SVM to classify fire or non-fire. We evaluate the proposed approach by comparing it with two state-of-the-art fire detection algorithms in terms of the fire detection rate (or percentages of true positive, PTP) and the false fire detection rate (or percentages of true negative, PTN). Experimental results indicated that the proposed approach outperformed conventional fire detection algorithms by yielding 97.94% for PTP and 4.63% for PTN, respectively.

Predictive value of sperm motility characteristics assessed by computer-assisted sperm analysis in intrauterine insemination with superovulation in couples with unexplained infertility

  • Youn, Joung-Sub;Cha, Sun-Hwa;Park, Chan-Woo;Yang, Kwang-Moon;Kim, Jin-Yeong;Koong, Mi-Kyoung;Kang, Inn-Soo;Song, In-Ok;Han, Sang-Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • Objective: To determine whether characteristics of sperm motility obtained by computer-assisted sperm analysis (CASA) could predict pregnancy after intrauterine insemination (IUI) in couples with unexplained infertility. Methods: Three hundred eighty-three cycles of intrauterine insemination with superovulation were retrospectively analyzed. Semen analysis was performed with CASA before and after swim-up and the parameters were compared between pregnant and non-pregnant women. Results: The pregnancy rate per cycle was 14.1%. Pregnant and non-pregnant women were comparable in terms of age, infertility duration, the number of dominant follicles. While sperm concentration, motility, and parameters such as average path velocity (VAP) and percentage rapid (RAPID) before semen preparation were significantly different between the pregnancy and non-pregnancy groups, there were no differences in sperm parameters when comparing the two groups after preparation. Using a receiver operating characteristic curve to measure sensitivity and specificity, the optimal threshold value for the predictors of pregnancy was revealed to be a concentration of ${\geq}111{\times}10^6/mL$, a motility of ${\geq}$ 51.4%, and RAPID ${\geq}$ 30.1% before preparation for IUI. Conclusion: Sperm parameters including concentration, motility, and RAPID before sperm preparation could have predictive value for pregnancy outcome after intrauterine insemination with superovulation in couples with unexplained infertility, and would be helpful when counseling patients before they make the decision to proceed with IVF/ICSI-ET.

Optimization of In Vivo Embryo Production and Pregnancy following Embryo Transfer in Hanwoo Cattle

  • Jeon, Soon-Hong;Jung, Kyoung Sub;Choi, Jae-Won;Heo, Young-Tae;Xu, Yong-Nan;Kim, Nam-Hyung
    • Journal of Embryo Transfer
    • /
    • v.28 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Embryos formed in vivo were collected from 171 donors housed in Chung Cheong Buk-Do Institute of Livestock and Veterinary Research of the Chungbuk community during the years 2009~2012. We evaluated annual embryo collection, effect of follicle stimulating hormone (FSH), controlled internal drug release (CIDR) and prostaglandin (PG) administration to the donor for superovulation and controlling the estrus cycle, seasonal effects of embryo collection and compared the number of embryos recovered as per the collection days and pregnancy rate. In all, 1,243 embryos were collected from 118 donors with an average of $7.31{\pm}5.35$ embryos per donor, out of which 69.4% were transferable. Dosages of FSH required for inducing superovulation in various donors were compared. Average number of embryos collected from donors administered with 30 AU of FSH ($7.13{\pm}5.74$ per donor) was not significantly different from that of donors who were given an injection of 24 AU of FSH ($7.53{\pm}4.91$ per donor). However, the percentage of transferable embryos in the 30AU FSH-administered group (63.2 %, 449 of 711) was higher than that in the 24AU FSH-administered group (77.8%, 414 of 532). In the group of donors under a natural estrus cycle, the FSH dose administered did not influence the number of transferable embryos produced ($7.49{\pm}6.25$ per donor for 30 AU of FSH vs $7.49{\pm}4.92$ per donor for 24 AU of FSH). However, in donors administered with CIDR and PG for controlling the estrus cycle, the FSH dose affected the average number of transferable embryos collected ($4.25{\pm}2.87$ per donor for 30 AU of FSH vs $8.50{\pm}6.36$ per donor for 24 AU of FSH). We collected embryos from donors 6, 7 or 8 days after artificial insemination (AI). Results showed that the percentage of transferable embryos among those collected 8 days after AI was significantly higher than that among embryos collected 6 or 7 days after AI. Seasonal variations did not affect number of recovered embryos and pregnancy rates in natural estrus cycle and CIDR treatment groups (48.28% and 42.55%) but higher than pregnancy rate of frozen embryos (19.63%). These results indicated that administration of FSH beyond a threshold dose (at least 24 AU) has no beneficial effect on the production embryos and that collection of embryos 7~8 days after AI is optimal for embryo recovery. CIDR treatment induced superovulation in short term and had no influence on the natural estrus cycle. Finally, although good-quality embryos were transferred, freezing significantly reduced the pregnancy rates after transfer.

A Study on the Improvement of Wavefront Sensing Accuracy for Shack-Hartmann Sensors (Shack-Hartmann 센서를 이용한 파면측정의 정확도 향상에 관한 연구)

  • Roh, Kyung-Wan;Uhm, Tae-Kyoung;Kim, Ji-Yeon;Park, Sang-Hoon;Youn, Sung-Kie;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.383-390
    • /
    • 2006
  • The SharkHartmann wavefront sensors are the most popular devices to measure wavefront in the field of adaptive optics. The Shack-Hartmann sensors measure the centroids of spot irradiance distribution formed by each corresponding micro-lens. The centroids are linearly proportional to the local mean slopes of the wavefront defined within the corresponding sub-aperture. The wavefront is then reconstructed from the evaluated local mean slopes. The uncertainty of the Shack-Hartmann sensor is caused by various factors including the detector noise, the limited size of the detector, the magnitude and profile of spot irradiance distribution, etc. This paper investigates the noise propagation in two major centroid evaluation algorithms through computer simulation; 1st order moments of the irradiance algorithms i.e. center of gravity algorithm, and correlation algorithm. First, the center of gravity algorithm is shown to have relatively large dependence on the magnitudes of noises and the shape & size of irradiance sidelobes, whose effects are also shown to be minimized by optimal thresholding. Second, the correlation algorithm is shown to be robust over those effects, while its measurement accuracy is vulnerable to the size variation of the reference spot. The investigation is finally confirmed by experimental measurements of defocus wavefront aberrations using a Shack-Hartmann sensor using those two algorithms.

Proposal of a New Type of 4-Lane Soundproof Tunnel Girder and Structural Performance Evaluation (4차선급 신형식 방음터널 거더 제안 및 구조적 성능평가)

  • Goh, Won-Hui;Kim, Min-Jae;Ma, Chuan;Kang, Duck-Man;Zi, Goang-Suep
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.24-31
    • /
    • 2021
  • The soundproof tunnels have been generally designed with H-beam girders, and the high weight of H-beam may cause the excessive design of the substructure. To solve this problem, this paper proposes a new soundproof tunnel girder design composed of pipes and discontinuous plates. First, the structural behavior of the straight girder according to the design parameters was examined through finite element analysis. The arrangement and shape of the plates were determined as the design parameter, to obtain the optimal design of girder. After then, the structural behavior and buckling stability of the arched girder were subsequently evaluated. As a result of the parameter analysis, it was confirmed that the axial force acting on the girder increased and the moment decreased as the ratio of unsupported sections decreased or the number of supporting plates increased. The stress concentration on the pipe member was relieved by increasing the long axis length of the elliptical plate. Arched girder analysis showed that the structural efficiency increase as the long axis of elliptical plate increase. As a result of the buckling evaluation, the buckling threshold load of the three connected girders was about 3.7 times higher than the design load. Consequently, it was confirmed that the proposed soundproof tunnel structure design satisfies both light weight and structural safety.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

Relationship between the Thyroid Hormone and Viral Infections in Pregnancy (임신 중 바이러스성 감염요인과 갑상선 호르몬의 상관성)

  • Lim, Dong-Kyu;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.1
    • /
    • pp.28-37
    • /
    • 2022
  • Pregnancy requires an important interpretation of thyroid function tests. The presence of anti-thyroid antibodies and viral infectious agents affect the health of both the fetus and the mother. Hence, a selective evaluation of thyroid function in pregnancy is required. This study is a retrospective cross-sectional survey to examine the correlation between thyroid hormones and viral infections during pregnancy. The results showed that the triiodothyronine (T3) decreased with increasing age, especially in the hepatitis C virus (HCV)-positive group (P<0.01). In addition, although negative for the human immunodeficiency virus (HIV), thyroxine (FT4) showed a significant increase in near-threshold or twin pregnant women (P<0.05). The thyroid stimulating hormone (TSH) was highly distributed at the age of 30, and there was no statistically significant correlation with other viral infection factors. In addition, as a result of dividing and analyzing the result of TSH by the quantiles, FT4 and T3 showed a positive correlation but showed a negative correlation with TSH (P<0.05). Therefore, the evaluation of prenatal thyroid screening during pregnancy and viral infection factors should reflect the time of pregnancy, exposure to infection, and the quantitative values. Adequate thyroid hormone and viral infections availability is important for an uncomplicated pregnancy and optimal fetal development.

Characteristics and Standards of Domestic Tidal Flat Mud Marine Healing Resources (국내 갯벌머드 해양치유자원의 특성 및 기준에 관한 연구)

  • Seonyoung Park;Jeongwon Kang;Yonggi Jeong;Yeonje Cho
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.386-393
    • /
    • 2023
  • The domestic marine healing industry is undergoing significant revitalization efforts, with a focus on understanding the efficacy and effectiveness of marine healing resources. This study establishes utilization and management standards through a detailed analysis of the active components within well-recognized marine healing mud materials. Samples of mud materials were collected from domestic tidal flats. These samples exhibited an average composition of 7.87% sand, 74.95% silt, and 17.17% clay, with a combined mud content (silt+clay)(silt+clay) consistently exceeding 90%. Notably, SiO2 emerged as the most prevalent effective ingredient at 68.4%, followed by Al2O3 (13.3%)>Fe2O3 (4.0%)>K2O (2.9%)>Na2O (2.3%)>MgO (1.6%)>CaO (1.0%)>TiO2 (0.7%), in terms of average content. Subsequently, through an analysis of effective ingredients, Si, Al, Fe, K, Na, Mg, and Ca were identified as elements demonstrating significant functionality. Among these, key indicator ingredients were selected for quality control, all of which were found to possess efficacious properties. Notably, K, Mg, and Ca exhibited particularly high concentrations. Based on these findings and referencing existing literature, it is recommended that domestic tidal flat mud resources earmarked for utilization as marine healing resources should possess a raw material mud content of no less than 70.0%. Moreover, the cumulative index components K2O+MgO+CaO should meet or exceed a threshold of 5.0% for optimal effectiveness.