• 제목/요약/키워드: optimal orthodontic force

검색결과 20건 처리시간 0.025초

교정력에 관한 임상적인 소고 (A Clinical Consideration of Orthodontic Force)

  • 김일봉;구옥경;성재현;김영수
    • 대한치과의사협회지
    • /
    • 제11권2호
    • /
    • pp.123-129
    • /
    • 1973
  • The authors measured orthodontic force using the orthodontic materials of the Rocky Mountain Products Company. The results were as follows : ① Use latex of wide diameter in long distance, and when the latex of wide diameter activated by four or five times, we obtained a optimal force. ② The authors obtained canine retractions with sectional arch. Activation of sectional arch began at 1mm and had to do not activations of 3mm more. ③ The leveling started from .014 green round wire and finished to. 0.16" green Elgiloy round wire. Permit only a mild force in ideal arch form, in rectangular wire. ④ Fundamentaly, elastic thread obtained maximum force by activating as two times. ⑤ Coil spring obtained more heavy force from short distance than long distance.

  • PDF

유한 요소법을 이용한 설측 치아교정시 전치부 후방 견인에 관한 연구 (Study on the Retraction of Anterior Teeth in the Lingual Orthodontics with the Three-Dimensional Finite Element Method)

  • 송정한;허훈;박현상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.198-203
    • /
    • 2004
  • In these days, the orthodontic surgery including lingual orthodontics has attracted a person' attention due to its functional and esthetic appreciation. The delivery of the optimal orthodontic treatment is greatly influenced by clinician' ability to predict and control the tooth movement by applying force system to dentition. The skeletal anchorage system with the miniscrew has been used recently in the lingual orthodontics to assist the anchorage control. Precise understanding of the force system produced from the various orthodontic appliances is necessary. However, the qualitative and quantitative effect of the miniscrew has not been identified well. In this paper, three dimensional finite element analysis is introduced on the lingual orthodontics to investigate the effect of anterior retraction force on the miniscrew and transpalatal arch wire. The purpose of this study is to determine the location of the miniscrew and the point of force application of the anchorage system in the lingual orthodontics. The analysis results indicate the efficient position of the miniscrew and the transpalatal arch wire in the lingual orthodontics.

  • PDF

An esthetic appliance for the management of crown-root fracture: a case report

  • Jeon, Sang-Min;Lee, Kang-Hee;Jung, Bock-Young
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.226-229
    • /
    • 2014
  • Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

유한요소법을 이용한 설측 치아교정시 전치부 후방견인에 관한 연구 (Study on the Retraction of Anterior Teeth for the Lingual Orthodontics with the Three-Dimensional Finite Element Method)

  • 송정한;허훈;박현상
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1237-1244
    • /
    • 2004
  • The orthodontic surgery including lingual orthodontics has recently attracted a person's attention due to its functional and esthetic appreciation. The skeletal anchorage with the miniscrew is newly adopted in the lingual orthodontics to assist the upholding ability. The appliciation needs to understand the mechanism of the orthodontic appliance and its related orthodontic correction for optimal orthodontic treatment. There is, however, few information about the qualitative and quantitative effect of the orthodontic appliance with the miniscrew has not been well identified. In this paper, three dimensional finite element analysis is introduced to the lingual orthodontics in order to investigate the effect of the anterior retraction force on the miniscrew and transpalatal arch wire. The analysis determines the adequate location of the miniscrew and the point of force application of the anchorage system in the lingual orthodontics. The analysis results demonstrate the effect of the position of the miniscrew and the transpalatal arch wire on the lingual orthodontics.

Comparisons of orthodontic root resorption under heavy and jiggling reciprocating forces during experimental tooth movement in a rat model

  • Hikida, Takuji;Yamaguchi, Masaru;Shimizu, Mami;Kikuta, Jun;Yoshino, Tomokazu;Kasai, Kazutaka
    • 대한치과교정학회지
    • /
    • 제46권4호
    • /
    • pp.228-241
    • /
    • 2016
  • Objective: Root mobility due to reciprocating movement of the tooth (jiggling) may exacerbate orthodontic root resorption (ORR). "Jiggling" describes mesiodistal or buccolingual movement of the roots of the teeth during orthodontic treatment. In the present study, buccolingual movement is described as "jiggling." We aimed to investigate the relationship between ORR and jiggling and to test for positive cell expression in odontoclasts in resorbed roots during experimental tooth movement (jiggling) in vivo. Methods: Male Wistar rats were divided into control, heavy force (HF), optimal force (OF), and jiggling force (JF) groups. The expression levels of cathepsin K, matrix metalloproteinase (MMP)-9 protein, interleukin (IL)-6, cytokine-induced neutrophil chemoattractant 1 (CINC-1; an IL-8-related protein in rodents), receptor activator of nuclear factor ${\kappa}B$ ligand (RANKL), and osteoprotegerin protein in the dental root were determined using immunohistochemistry. Results: On day 21, a greater number of root resorption lacunae, which contained multinucleated odontoclasts, were observed in the palatal roots of rats in the JF group than in rats from other groups. Furthermore, there was a significant increase in the numbers of cathepsin K-positive and MMP-9-positive odontoclasts in the JF group on day 21. Immunoreactivities for IL-6, CINC-1, and RANKL were stronger in resorbed roots exposed to jiggling than in the other groups on day 21. Negative reactivity was observed in the controls. Conclusions: These results suggest that jiggling may induce ORR via inflammatory cytokine production during orthodontic tooth movement, and that jiggling may be a risk factor for ORR.

골성 고정원과 편측 분절호선을 이용한 정출된 상악 중절치의 압하 치료 (Intrusion of the extruded maxillary central incisor using skeletal anchorage system and unilateral segmental intrusion arch)

  • 권은영;백영재;박수병;김성식;김용일;최윤경
    • 구강회복응용과학지
    • /
    • 제35권3호
    • /
    • pp.180-190
    • /
    • 2019
  • 병적 치아 이동된 상악 전치를 가진 중등도 치주염 환자에서는 치태 관리를 통한 치주 염증의 해소뿐만 아니라 치아를 재위치 시키기 위한 교정치료가 함께 필요하다. 이 때의 교정치료는 더 적은 힘의 적용과 치아의 저항중심, 최적의 힘 등을 세심하게 고려해야 하는데, 이동하고자 하는 치아에만 적용되는 분절호선은 이동의 예측성을 높여주고, 힘을 조절할 수 있어 보다 효율적이다. 또한 교정치료 시, 고정원으로 사용되는 치아의 원치 않는 움직임을 차단하여 구치 교합 상태를 유지할 수 있는 장치 설계가 필요하며, 이를 위해 다양한 종류의 골성 고정원이 사용될 수 있다. 본 증례에서는 정출되고 변위된 상악 전치를 가진 환자에서, 철저한 치주 치료와 적절한 힘과 역학이 설계된 교정 장치로, 양호한 치료 결과를 얻을 수 있었으므로, 소개하고자 한다.

최적구조설계를 이용한 교정브라켓 성능향상에 관한 연구 (A Study on Improvement of Correction Bracket Performance Using Optimal Structural Design)

  • 이정화;권현규;권동재;박상준;전유진
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.27-32
    • /
    • 2022
  • There has always been a demand for orthodontic treatment. Orthodontic treatment allows tooth to be arranged by flexible arch wire fixed with tooth-attached brackets. Arch wire generate constant pressure to tooth brackets which moves the teeth to proper place. When the bracket transmits force, the braced wing of the bracket may deform. Deformed tie wing will lead to lost tension of elastic ligature. Then, lacking grip between tie wing and ligature might delay the tooth movement. Furthermore, tooth brackets used for orthodontic treatment make contact with in direct oral surface and this cause feeling of irritation that comes from height of tooth braces. This study suggests an optimal teethe bracket design to make up for inconvenience by shorten the height of bracket and complement the shape of bracket to reduce strain rate using finite element analysis. As a result, new optimal design of teethe bracket indicates lower strain rate of the bracket wing and takes good effects of shorten body height in terms of convenience.

견치 원심이동시의 초기변화에 관한 유한요소법적 연구 (A STUDY ON INITIAL CHANGES DURING CANINE RETRACTION BY THE FINITE ELEMENT METHOD)

  • 김영원;손병화
    • 대한치과교정학회지
    • /
    • 제18권1호
    • /
    • pp.25-53
    • /
    • 1988
  • Retraction of canines represents a fundamental stage in a considerable number of orthodontic treatment. Correct position of the canine after retraction is most important for function, stability, and esthetics. The purpose of this study was to investigate the stress in the periodontal tissue at the initial phase during canine retraction using various types of sectional retraction springs, by finite element method. Three dimensional model of tooth, periodontal ligament, bone and eight springs were simulated and tested. The following results were obtained. 1. In sectional retraction springs, increasing number of helix and the closed loop in preference to the open loop provided an decrease in horizontal force. Without angulating the arms of spring, the T-loop revealed the highest Moment-to-force ratio. 2. The Moment-to-force ratio raised by angulating mesial and distal arms of spring, but very large horizontal force was applied to canine. 3. When optimal force and optimal moment was applied to canine, the stress induced was homogeneous and the difference of stress value from cervix to the apex was little.

  • PDF

Prediction of optimal bending angles of a running loop to achieve bodily protraction of a molar using the finite element method

  • Ryu, Woon-Kuk;Park, Jae Hyun;Tai, Kiyoshi;Kojima, Yukio;Lee, Youngjoo;Chae, Jong-Moon
    • 대한치과교정학회지
    • /
    • 제48권1호
    • /
    • pp.3-10
    • /
    • 2018
  • Objective: The purpose of this study was to predict the optimal bending angles of a running loop for bodily protraction of the mandibular first molars and to clarify the mechanics of molar tipping and rotation. Methods: A three-dimensional finite element model was developed for predicting tooth movement, and a mechanical model based on the beam theory was constructed for clarifying force systems. Results: When a running loop without bends was used, the molar tipped mesially by $9.6^{\circ}$ and rotated counterclockwise by $5.4^{\circ}$. These angles were almost similar to those predicted by the beam theory. When the amount of tip-back and toe-in angles were $11.5^{\circ}$ and $9.9^{\circ}$, respectively, bodily movement of the molar was achieved. When the bend angles were increased to $14.2^{\circ}$ and $18.7^{\circ}$, the molar tipped distally by $4.9^{\circ}$ and rotated clockwise by $1.5^{\circ}$. Conclusions: Bodily movement of a mandibular first molar was achieved during protraction by controlling the tip-back and toe-in angles with the use of a running loop. The beam theory was effective for understanding the mechanics of molar tipping and rotation, as well as for predicting the optimal bending angles.

교정용 선재의 TORQUE 효과에 관한 연구 (A STUDY ON THE TORQUE EFFECT OF ORTHODONTIC WIRES)

  • 임정현;김상철
    • 대한치과교정학회지
    • /
    • 제24권1호
    • /
    • pp.87-94
    • /
    • 1994
  • The purpose of this study was to evaluate the torque effect of othodontic wires. Ten types of orthodontic wires (five types of materials, two types of cross-sectional dimensions) were selected. Each group of ire type was constituted with five specimens. These specimens were tested on the universal testing machine(Instron) with specially-designed jig. The torque-twist curve of each wire was obtained and the results were analyzed statistically. The results were as follows. 1. 0.017'$\times$ 0.025' wire showed more torque effect than 0.016'$\times$ 0.022' wire at the same twist. 2.Torque effect was the greatest in stainless steel and the least in Nitinol. 3.The maximum amount of torque was the greatest in heat-treated Blue Elgiloy and the least in Nitinol.

  • PDF