• 제목/요약/키워드: optimal operating frequency

검색결과 149건 처리시간 0.03초

단결정 실리콘 태양전지 최적 운전조건을 위한 주파수 특성 분석 (Analysis of Frequency Property for Optimal Operating Conditions of Mono-crystalline Si Solar Cell)

  • 김지웅;최용성;이경섭;조수영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2060-2060
    • /
    • 2011
  • This paper was investigated the frequency property for optimal operating conditions of mono-crystalline Si solar cell. An internal impedance of mono-crystalline Si solar cell was influenced frequency. An optimal operating conditions of solar cell was under about 10[kHz].

  • PDF

스터링 극저온 냉동기 성능의 운전주파수 의존성에 관한 연구 (Study of the Dependency of the Stirling Cryocooler′s Thermodynamic Performance on the Operating Frequency)

  • 홍용주;박성제;김효봉;유병건;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.140-144
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stirling cryocooler has been widely used for the cooling infrared and cryo-sensor. The thermodynamic performance of the free piston and free displacer type (FPFD) Stirling cryocooler is highly dependent on the operating frequency of the linear compressor and the natural frequency of the displacer. In this study, to find optimal relation between operating and natural frequency of the displacer the dynamic characteristics of the displacer in the expansion space of the Stirling cooler was investigated by experiment. The experimental results show that the Stifling cryocooler has maximum cooling capacity at the operating frequency of about 0.8 times of the natural frequency of displacer. Therefore the operating frequency of the Stirring cryocooler should be determined by natural frequency of the linear compressor and displacer.

On Power System Frequency Control in Emergency Conditions

  • Bevrani, H.;Ledwich, G.;Ford, J. J.;Dong, Z.Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.499-508
    • /
    • 2008
  • Frequency regulation in off-normal conditions has been an important problem in electric power system design/operation and is becoming much more significant today due to the increasing size, changing structure and complexity of interconnected power systems. Increasing economic pressures for power system efficiency and reliability have led to a requirement for maintaining power system frequency closer to nominal value. This paper presents a decentralized frequency control framework using a modified low-order frequency response model containing a proportional-integral(PI) controller. The proposed framework is suitable for near-normal and emergency operating conditions. An $H_{\infty}$ control technique is applied to achieve optimal PI parameters, and an analytic approach is used to analyse the system frequency response for wide area operating conditions. Time-domain simulations with a multi-area power system example show that the simulated results agree with those predicted analytically.

이중여자 유도발전기의 정출력.최적역률 운전 (A constant power and optimal power factor drive of doubly fed induction generator)

  • 이우석
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.31-38
    • /
    • 2000
  • 본 논문에서는 동기속도 이상의 풍속 영역에서 계풍연계된 DFTG(Doubly-Fed Induction Generaior) 시스템올 이용하여 발전기의 속도, 출력, 역률 제어에 대한 연구를 하였다. 이를 위하여 회전자 권선을 통하여 회전자 여자 주파수와 전압을 인가하였고,DBG의 전력소류와 등가회로의 정상상태 식을 해석하였다. 발전기의 속도와 고점차 일정출력제어는 회전자 여자주파수에 의해 이루어지고, 발전기의 정상적인 동작은 회전자 여자전류가 정격값올 넘어서는 안된다. 따라서 회전자 여자주파수에 의한 일정 출력운전상태에서 회전자 여자전류를 정격값이 되도록 회집자 여자전압을 제어여, 고정자 역률이 최적이 되도 DFIG를 운전하였다.

  • PDF

A New Approach to Adaptive Damping Control for Statistic VAR Compensators Based on Fuzzy Logic

  • Sedaghati, Alireza
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.825-829
    • /
    • 2005
  • This paper presents an approach for designing a fuzzy logic-based adaptive SVC damping In controller for damping low frequency power oscillations. Power systems are often subject to low Frequency electro-mechanical oscillations resulting from electrical disturbances. Generally, power system stabilizers are designed to provide damping against this kind of oscillations. Another means to achieve damping is to design supplementary damping controllers that are equipped with SVC. Various approaches are available for designing such controllers, many of which are based on the concepts of damping torque and others which treat the damping controller design as a generic control problem and apply various control theories on it. In our proposed approach, linear optimal controllers are designed and then a fuzzy logic tuning mechanism is constructed to generate a single control signal. The controller uses the system operating condition and a fuzzy logic signal tuner to blend the control signals generated by two linear controllers, which are designed using an optimal control method. First, we design damping controllers for the two extreme conditions; the control action for intermediate conditions is determined by the fuzzy logic tuner. The more the operating condition belongs to one of the two fuzzy sets, the stronger the contribution of the control signal from that set in the output signal. Simulation studies done on a one-machine infinite-bus and a four-machine two-area test system, show that the proposed fuzzy adaptive damping SVC controller effectively enhances the damping of low frequency oscillations.

  • PDF

무선 센서 노드용 진동형 마이크로 압전 에너지 하베스팅 설계 및 분석 (Design and analysis of vibration micro piezoelectric energy harvesting for wireless sensor nodes)

  • 윤규형;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.277-277
    • /
    • 2009
  • In this paper, PMPG (Piezoelectric Micro Power Generator) was investigated by ANSYS FEA (Finite Element Analysis) to decrease operating frequency and improve out power. The micro power generator was designed to convert ambient vibration energy to electrical power as a ZnO piezoelectric material. To find optimal model in low vibration ambient, the shape of power generator was changed with different membrane width, thickness, length, and proof mass size. Used the ANSYS modal analysis, bending mode and stress distribution of optimal model were analyzed. Also, the displacement with the frequency range was analyzed by harmonic analysis. From the simulation results, the resonance frequency of optimal model is about 373 Hz and confirmed the possibility of ZnO micro power generator for wireless sensor node applications.

  • PDF

국가적 관점에서 각 용도별 ESS 적정용량 산정을 위한 투자수리모델 수립에 관한 연구 (Study on Establishing Investment Mathematical Models for Each Application ESS Optimal Capacity in Nationwide Perspective)

  • 김정훈;윤석민
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.979-986
    • /
    • 2016
  • At present, electric power industry around the world are being gradually changed to a new paradigm, such as electrical energy storage system, the wireless power transmission. Demand for ESS, the core technology of the new paradigm, has been growing worldwide. However, it is essential to estimate the optimal capacity of ESS facilities for frequency regulation because the benefit would be saturated in accordance with the investment moment and the increase of total invested capacity of ESS facilities. Hence, in this paper, the annual optimal mathematical investment model is proposed to estimate the optimal capacity and to establish investment plan of ESS facility for frequency regulation. The optimal mathematical investment model is newly established for each season, because the construction period is short and the operation effect for the load by seasons is different unlike previous the mathematical investment model. Additionally, the marginal operating cost is found by new mathematical operation model considering no-load cost and start-up cost as step functions improving the previous mathematical operation model. ESS optimal capacity is established by use value in use iterative methods. In this case, ESS facilities cost is used in terms of the value of the beginning of the year.

Simultaneous Control of Frequency Fluctuation and Battery SOC in a Smart Grid using LFC and EV Controllers based on Optimal MIMO-MPC

  • Pahasa, Jonglak;Ngamroo, Issarachai
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.601-611
    • /
    • 2017
  • This paper proposes a simultaneous control of frequency deviation and electric vehicles (EVs) battery state of charge (SOC) using load frequency control (LFC) and EV controllers. In order to provide both frequency stabilization and SOC schedule near optimal performance within the whole operating regions, a multiple-input multiple-output model predictive control (MIMO-MPC) is employed for the coordination of LFC and EV controllers. The MIMO-MPC is an effective model-based prediction which calculates future control signals by an optimization of quadratic programming based on the plant model, past manipulate, measured disturbance, and control signals. By optimizing the input and output weights of the MIMO-MPC using particle swarm optimization (PSO), the optimal MIMO-MPC for simultaneous control of the LFC and EVs, is able to stabilize the frequency fluctuation and maintain the desired battery SOC at the certain time, effectively. Simulation study in a two-area interconnected power system with wind farms shows the effectiveness of the proposed MIMO-MPC over the proportional integral (PI) controller and the decentralized vehicle to grid control (DVC) controller.

경쟁적 전력시장에서 상정사고를 고려한 에너지와 주파수 제어예비력의 최적배분 기법 (Optimal Dispatch of Energy and Frequency Regulation Reserve Considering Contingency in a Competitive Electricity Market)

  • 이기송;정윤원;신중린;전영환;박종배
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권5호
    • /
    • pp.202-213
    • /
    • 2006
  • This paper presents a new approach for optimal dispatch of energy and frequency regulation reserve considering contingency in a competitive electricity market. It is necessary to introduce the reserve market with the spot energy market for operating efficiently and obtaining the security of the electricity market. However, the reserve market is closely connected with the energy market since the energy and reserve are produced from the same resources. Thus, it is inevitable to co-optimize the energy and ancillary service for efficient operation of energy and ancillary service market. Therefore, this paper proposes a new method for optimal dispatch of energy and frequency regulation reserve considering n-1 contingency of generator and transmission line using constraints and sensitivity based on AC power flow To verify the effectiveness of the proposed method, the numerical studies have been performed for 5-bus sample system and modified IEEE 14-bus system.

시동전류 제한을 통한 메탈헬라이드 램프용 안정기의 최적 설계 (A New Optimal Design Method of the Electronic Ballast for MHL with Stable Run-up Current)

  • 임병로;장목순;임기승;박종연
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.409-415
    • /
    • 2008
  • This paper proposed a new optimal design method of the electronic ballast with stable run-up current for Metal Halide lamp during the ignition condition. In order to avoid operation in the acoustic resonance frequency band and to supply the optimal ignition current without demage of inverter switching components during the ignition period, the values of the series inductor Ls, the series capacitor Cs, and the parallel capacitor Cp were determined by analysis of characteristics of inverter transfer function depend on Lamp operating power and resistance of ignition condition and steady state operating condition. For the prototype ballast for a 400W Metal Halide Lamp, experimental results are presented in order to validate the proposed method.