• 제목/요약/키워드: optical penetration depth

검색결과 43건 처리시간 0.031초

The Effect of an Optical Clearing Agent on Tissue Prior to 1064-nm Laser Therapy

  • Youn, Jong-In
    • Medical Lasers
    • /
    • 제10권3호
    • /
    • pp.146-152
    • /
    • 2021
  • Background and Objectives Although lasers have been widely applied in tissue treatment, the light penetration depth in tissues is limited by the tissue turbidity and affected by its absorption and scattering characteristics. This study investigated the effect of using an optical clearing agent (OCA) on tissue to improve the therapeutic effect of 1064 nm wavelength laser light by reducing the heat generated on the skin surface and increasing the penetration depth. Materials and Methods A diode laser (λ = 1064 nm) was applied to a porcine specimen with and without OCA to investigate the penetration depth of the laser light and temperature distribution. A numerical simulation using the finite element method was performed to investigate the temperature distribution of the specimen compared to ex-vivo experiments using a thermocouple and double-integrating sphere to measure the temperature profile and optical properties of the tissue, respectively. Results Simulation results showed a decrease in tissue surface temperature with increased penetration depth when the OCA was applied. Furthermore, both absorption and scattering coefficients decreased with the application of OCA. In ex-vivo experiments, temperatures decreased for the tissue surface and the fat layer with the OCA, but not for the muscle layer. Conclusion The use of an OCA may be helpful for reducing surface heat generation and enhance the light penetration depth in various near-infrared laser treatments.

광섬유전송에 의한 Zircaloy-4 봉단마개밀봉의 Nd:YAG LBW의 최적조건에 관한 연구 (A study on the Optimum Conditions of Nd:YAG LBW for Zircaloy-4 End Cap Closure By Optical Fiber Transmission)

  • 김수성;김웅기;이영호
    • Journal of Welding and Joining
    • /
    • 제15권6호
    • /
    • pp.85-95
    • /
    • 1997
  • This study is to investigate the optimum conditions of Nd:YAG laser beam welding for Zircaloy-4 end cap closure by optical fiber transmission. Laser welding parameters which affect the penetration depth and bead width were experimentally examined using the various beam radius by the beam quality analyzer, joint geometries of end cap and the laser parameters which mean pulse width, repetition rate and pulse energy. Also, an optimum welding speed and the effect of assistant gas with varying the flow rate of He were investigated. We found that the laser average power for the end cap welding will be 230W and rotation speed must not exceed 8 RPM, the best position of focus using optical fiber with 600.mu.m will be 2 to 3mm below the surface of the material.

  • PDF

Laser Welding Quality Monitoring with an Optical Fiber System

  • Kim, Jin-Tae;Kim, Do-Hyoung;Chung, Chin-Man;Baik, Sung-Hoon;Park, Seung-Kyu;Kim, Min-Suk
    • Journal of the Optical Society of Korea
    • /
    • 제7권3호
    • /
    • pp.193-196
    • /
    • 2003
  • We have developed a laser welding monitoring system to monitor laser welding process conditions such as sample feed rate, laser focal position, and laser power. A 2 ㎾ Nd:YAG CW laser beam has been applied to the welding of a stainless steel plate (SUS306) to investigate the welding monitoring. Theradiation signal from the weld pool was guided back through the focusing optics and the laser delivery fiber, and measured by a photo detector. By changing the focus of the laser beam along the z-direction, the penetration depth of the welding material has been measured. That shows the penetration depth depends on the frequency fluctuations of the plume signals which can be used in welding quality control.

Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging

  • Nam, Seung Yun;Emelianov, Stanislav Y.
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.151-155
    • /
    • 2014
  • Although various ophthalmic imaging methods, including fundus photography and optical coherence tomography, have been applied for effective diagnosis of ocular diseases with high spatial resolution, most of them are limited by shallow imaging penetration depth and a narrow field of view. Also, many of those imaging modalities are optimized to provide microscopic anatomical information, while functional or cellular information is lacking. Compared to other ocular imaging modalities, photoacoustic imaging can achieve relatively deep penetration depth and provide more detailed functional and cellular data based on photoacoustic signal generation from endogenous contrast agents such as hemoglobin and melanin. In this paper, array-based ultrasound and photoacoustic imaging was demonstrated to visualize pigmentation in the eye as well as overall ocular structure. Fresh porcine eyes were visualized using a real-time ultrasound micro-imaging system and an imaging probe supporting laser pulse delivery. In addition, limited photoacoustic imaging field of view was improved by an imaging probe tilting method, enabling visualization of most regions of the retina covered in the ultrasound imaging.

주파수 영역 분광법을 이용한 생체의 광학계수 측정법 연구 (Measurement of Optical Parameters of Biological Tissues by Using the Frequency-Domain Spectroscopy)

  • 전계진;윤길원;김홍식;김원기;이정한;박승한;김웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.379-382
    • /
    • 1997
  • A method for measuring optical properties of biological medium was investigated by using the frequency domain spectroscopy. When amplitude-modulated light with the frequency of several tens up to several hundred MHz propagates through a scattering medium, the phase lag and the amplitude reduction occur. The phase lag depends on the average of optical path lengths. The amplitude reduction with respect to the radial distance is influenced by the penetration depth. The mean of optical path length and penetration depth are related to optical coefficients. The phase lag and the amplitude reduction were measured based on the heterodyne detection method. The experimental data were fitted with the theoretical curves derived from diffusion theory and the absorption and scattering coefficients were calculated.

  • PDF

브라운관 전자총 부품의 펄스 Nd:YAG레이저 용접에 관한 연구 (I) - 빔의 출력특성과 광학변수 - (A Study on Pulsed Nd:YAG Laser Welding of Electron Gun in Braun Tubes (I) - Characteristics of Beam Output Energy and Optical Parameters -)

  • 김종도;하승협;조상명
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.525-534
    • /
    • 2002
  • During laser spot welding of the braun tube electron gun, phenomena such as serious spattering and oxidative reaction, etc. were occurred. The spatter occurred from weld pool affects the braun tube, namely it blocks up a very small hole on the shadow mask and causes short circuit between two roles of the electron gun. We guessed that high power density and oxidative reaction are main sources of these problems. So, we studied to prevent and to reduce spatter occurring in spot welding of the braun tube electron gun using pulsed Nd:YAG laser. The characteristics of laser output power was estimated, and the loss of laser energy by optical parameter and spatter was measured by powermeter. The effects of welding parameters, laser defocused distance and incident angle, were investigated on the shape and penetration depth of the laser welded bead in flare and flange joints. From these results, the laser peak power was a major factor to control penetration depth and to occur spatter. It was found that the losses of laser energy by optic parameter and sticked spatter affect seriously laser weldability of thin sheets. The deepest penetration depth is gotten on focal position, and a "bead transition" occurred with a slight displacement of focal position relative to the workpiece surface and the absorption rate of the laser energy is affected by the shape factor of the workpiece. When we changed the incident angle of laser beam, the penetration depth was decreased a little with increasing of the incident angle, and the bead width was increased. The spattering was prevented by considering laser beam energy and incident angle.ent angle.

초단파 레이저 조사시 티슈 열완화 시간 분석 (Analysis of Thermal Relaxation Time of Tissues Subject to Pulsed Laser Irradiation)

  • 김경한;이제훈;서정
    • 한국레이저가공학회지
    • /
    • 제12권2호
    • /
    • pp.17-25
    • /
    • 2009
  • Two methodologies for predicting thermal relaxation time of tissue subjected to pulsed laser irradiation is introduced by the calculation the optical penetration depth and by the investigation of the temperature diffusion behavior. First approach is that both x-axial and y-axial thermal relaxation times are predicted and they are superposed to achieve the thermal relaxation time (${\tau}_1$) for two-dimensional square tissue model. Another approach to achieve thermal relaxation time (${\tau}_2$) is measuring the time required for local temperature drop until $e^{-1}$ of the maximum laser induced heating.

  • PDF

미세균열이 콘크리트의 염소이온 침투에 미치는영향 II: 임계 균열폭의 고찰 (Effect of Micro-Cracks on Chloride Ions Penetration of Concrete II: Examination of Critical Crack Width)

  • 윤인석
    • 콘크리트학회논문집
    • /
    • 제19권6호
    • /
    • pp.707-715
    • /
    • 2007
  • 다공질성 특성을 갖는 콘크리트는 충분한 다짐과 양생 조건에서 장수명을 갖으며, 유해 물질의 주요 경로는 공극이다. 그러나 균열이 발생한 콘크리트의 경우, 균열은 염소이온과 같은 유해 물질의 우선적인 침투 경로가 된다. 균열이 염소에 미치는 영향은 균열폭과 균열 깊이의 크기에 의존한다. 본 연구는 미세균열이 콘크리트의 염소이온 침투에 미치는 영향을 다룬 실험적 연구로서, 연구 목적은 균열폭과 균열 깊이 등의 균열 크기 효과가 염소이온에 미치는 영향을 고찰하는 것이다. 균열을 통한 염소이온의 침투를 시각화 하기 위하여, 급속 염소이온 침투 실험인 RCM (rapid chloride migration) 실험을 수행하였다. 균열폭과 균열 깊이는 전자 현미경으로 관찰하였고, 평균적인 균열폭을 산정하기 위하여 균열 개구 변위가 측정되었다. 다양한 균열 크기에 따른 염소이온의 침투 깊이 및 염소이온 확산계수의 변화율로부터 염소이온이 침투되지 않는 균열 깊이 및 이에 대응한 균열폭이 도출되었다.

Evaluation of Adhesive Characteristics of Mixed Cross Laminated Timber (CLT) Using Yellow Popular and Softwood Structural Lumbers

  • Keon-Ho KIM;Hyun-Mi LEE;Min LEE
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권1호
    • /
    • pp.58-69
    • /
    • 2024
  • To evaluate the adhesive characteristics of mixed cross-laminated timber (CLT) using domestic softwoods structural lumber proposed by KS F 3020 and yellow poplar, penetration depth of adhesive and thickness of bonding line were analyzed based on the results of boiling water soaking delamination. 3 Types of adhesives and 2 types of major layer were divided into a 5 ply CLT using yellow popular as minor layer. The bonding performance of the mixed CLT as structural members was evaluated based on the KS F 2081. The thickness of bonding line between layers of the mixed CLT was measured with a scanning electron microscope, and the adhesive penetration depth in the layer members was measured with an optical microscope. As a result of boiling water soaking delamination test of mixed CLT, the CLT specimens using PRF and PUR adhesives met the requirements of KS F 2081. It was verified that the penetration path of the adhesive in the layes was mainly through the tracheid cell in the case of Japanese larch and Korean red pine layers, and through the vessel and radial tissue in yellow popular layers. The penetration depth of the adhesive was the highest for the PRF adhesive under the same pressing time conditions, and the thickness of the bonding line was in inverse proportion to the penetration depth in the case of the PUR adhesive.

동해 북동해역에서의 해수의 광학적 성질 (OPTICAL PROPERTIES OF SEA WATER IN THE JAPAN SEA)

  • 양용림
    • 한국수산과학회지
    • /
    • 제10권3호
    • /
    • pp.173-177
    • /
    • 1977
  • 1976년 9월부터 10월 사이에 동해 북동해역 9개 관측점에서 투명도, 태양광선의 적색광(파장;$600\~620nm$)에 대한 수심별 수중조도와 태양고도 등을 조사하여 검토한 결과를 요약하면 다음과 같다. 1. 본 조사해역의 평균투명도는 $19.8m(15\~23m)$로 나타났다. 2. 태양광선의 적색광에 대한 해수의 흡수계수는 $0.142\~0.323$(평균 0.232)였다. 3. 적색광에 대한 해수의 흡수계수 m와 투명도 D와의 관계는 m=4.93/D로 나타났다. 4. 적색강의 수중투과율은 수성 5m층에서 표면광의 $15\~34.2\%$(평균 $23.11\%$), 수신 10m층에서는 $3.04\~12\%$(평균 $6.49\%$)였고, 수심 20m층에서는 $0.113\~1.27\%$(평균 $0.698\%$)로 나타났다.

  • PDF