• 제목/요약/키워드: optical particle counter

검색결과 52건 처리시간 0.028초

광학입자계수기를 이용한 안면도 연직 에어러솔 수농도 크기 분포 특성 (Features on the Vertical Size Distribution of Aerosols using Ballon-borne Optical Particle Counter at Anmyeon)

  • 최병철;;임재철;정상부;김윤석;;;;김상백;홍기만;이영곤;유희정
    • 대기
    • /
    • 제15권3호
    • /
    • pp.149-153
    • /
    • 2005
  • A balloon-borne Optical Particle Counter (hereafter "OPC Sonde"), which was developed by the atmospheric research group of Nagoya University, is used for getting the information of vertical profile of particle size and concentration in Anmyeon ($36^{\circ}32^{\prime}N$ $126^{\circ}19^{\prime}E$) on 18 March 2005. A range of five different particle sizes is shown in the vertical profile of aerosol number density estimated from the OPC Sonde. It was found that small size particles have vertically larger aerosol number density than relatively big ones. For all size ranges the vertical aerosol number density shows a decreased pattern as the altitude becomes higher. The aerosol number density of $0.3{\sim}0.5{\mu}m$, $0.5{\sim}0.8{\mu}m$, $0.8{\sim}1.2{\mu}m$ size ranges at the 10km height, which is the tropopause approximately, are $1,000,000ea/m^3$, $100,000ea/m^3$, $10,000ea/m^3$ respectively. The data of OPC Sonde are also compared with the data of PM10 $\beta$-ray) and Micro Pulse Lidar which are operating at Korea Global Atmosphere Watch Observatory in Anmyeon.

FMS를 지원하는 블루투스 기반의 4-채널 미세 입자 계수기 개발 (Development of 4-Channel Particle Counter based on bluetooth Supporting FMS)

  • 엄우용;구자일;박성욱
    • 전자공학회논문지
    • /
    • 제51권3호
    • /
    • pp.185-193
    • /
    • 2014
  • 본 논문에서는 클린 룸 환경의 생산 설비에서 발생하는 미세입자, 온도, 습도 값을 측정하여 블루투스 통신을 통해 전송하는 4-채널 미세입자 계수기를 개발하였다. 이를 위해 광학 렌즈와 입자 검출 챔버를 설계하고, 미세 검출 회로를 다채널로 설계하여 $0.3{\mu}m$에서 $5{\mu}m$ 내외의 미세 입자를 측정할 수 있도록 하였다. 그리고 측정된 값을 상시 모니터링 하기 위해 FMS(Facility Monitoring Systems) 프로그램을 개발하고, 실험을 통해 개발된 시스템이 안정적으로 동작함을 확인하였다.

액적 발생 장치 개발 및 성능 평가 (Development and Performance Evaluation of a Liquid Particle Generator)

  • 허정혁;김대성
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.4334-4340
    • /
    • 2012
  • 본 연구에서는 미세 액적을 발생시키는 액적 발생 장치를 개발 제작하고 이에 대한 성능 평가를 실시하였다. 액적 발생 장치는 spray-evaporation method를 기초로 제작하였으며, 0.3mm, 0.5mm의 오리피스를 사용하였다. 압축 공기 공급 압력을 1bar에서 4bar로 증가시키면서 공급 압력에 따른 발생되는 액적 크기의 미세 정도를 비교하였다. 또한 SMPS(Scanning Mobility Particle Sizer)와 OPC(Optical Particle Counter)를 이용하여 서로 다른 오리피스를 장착한 액적 발생 장치에서 발생되는 액적의 크기 분포를 측정하였다. 연구 결과, 0.3mm 오리피스를 장착한 장치에서 발생되는 액적은 $0.3{\mu}m$ 인근의 크기가 가장 많았으며, 미립화되는 입자는 매우 안정적이었다. 또한 0.5mm 오리피스를 장착한 장치가 0.3mm 오리피스를 장착한 장치에 비해 발생되는 액적의 크기가 큰 것으로 나타났다. 이러한 액적 발생 장치는 입자의 미세한 응집 현상이 나타나는데, 이것은 내부 액체가 미세한 액적으로 미립화되어 분사되기 때문인 것으로 사료된다. 본 연구에서 제작한 액적 발생 장치는 미세 입자를 미립화하기 위한 에어로졸 발생 장치로 사용 가능한 것으로 판단된다.

광학 입자 측정기 비교 측정에 의한 입경별 일평균 블랙카본 분석 - Part I (Diurnal Size Distributions of Black Carbon by Comparison of Optical Particulate Measurements - Part I)

  • 박다정;이광열;박기홍;배민석
    • 한국대기환경학회지
    • /
    • 제32권1호
    • /
    • pp.1-8
    • /
    • 2016
  • Optical particle sizer (OPS), optical particle counter (OPC), and aethalomter were deployed to measure the particle number concentrations from 0.3 to $10.0{\mu}m$ and black carbon (BC) concentrations. Comparisons of particle number concentrations measured by OPS and OPC were conducted to evaluate the performance of the each optical instrument at the Gwangju sampling site ($35.23^{\circ}N$, $126.84^{\circ}E$) for 14 days from Dec. 27 in 2014. Although a good correlation ($r^2=0.99$) between the OPS and OPC was observed for both the particle number and volume concentrations, different relationships by BC concentrations can be associated with the intensities by different light scattering angles. In addition, based on diurnal patterns of size distributions in 24 hr running correlation coefficient determination, BC concentrations were highly related to the particles less than $0.3{\mu}m$ observed in the morning traffic hour.

대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정 (Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air)

  • 김종범;김단비;노수진;윤관훈;박덕신;이정주;김정호
    • 한국입자에어로졸학회지
    • /
    • 제16권2호
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

축류형 사이클론을 이용한 공기역학경과 광학직경 상관관계 분석에 관한 연구 (A Study on Correlation Analysis between Aerodynamic Diameter and Optical Diameter Using Axial Flow Cyclone)

  • 김은정;박경려;허지은;조철희;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.155-164
    • /
    • 2023
  • APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.

대기중 에어로졸 입경분포의 변화 (Variations of Aerosol Size Distribution on Ambient Air)

  • 김신도;안기석;김종호;김태식
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.83-84
    • /
    • 1999
  • 시정악화나 광화학 스모그를 비롯하여 지구 온난화에 부유 입자상 물질이 미치는 영향 등을 파악하기 위해선 중량농도, 화학적 성분분석 등과 함께 그 입경별 크기 분포도 반드시 고려되어야만 한다. 입경분포 측정을 위하여 다단식 임팩터(Cascade Impactor)나 광학입자계수기(OPC, Optical Particle Counter), Aerosizer, SMPS (Scanning Mobility Particle Sizer), EAA(Electrical Aerosol Analyzer) 등 이주로 사용되고 있다.(중략)

  • PDF

입자의 굴절률변화에 따른 광학적 입자 계수기로 측정된 대기 에어러솔 크기분포의 측정오차 (Particle Refractive Index Effects on Aerosol Size Distribution Measured by An Optical Particle Counter)

  • 이권호;김영준;정희숙;정창훈
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 추계학술대회 논문집
    • /
    • pp.314-315
    • /
    • 2002
  • 대기중에는 다양한 크기와 모양, 그리고 화학성분을 가진 입자들이 존재한다. 이러한 입자들은 발생원이 다양하고 대기중에 존재하면서 광화학적인 변화를 거쳐 형성되기도 한다. 입자의 화학조성과 크기는 발생원을 구분하기 위한 일반적인 척도로 쓰이고 있다. 대기 에어러솔의 크기분포특성은 에어러솔의 변화 요소인 발생원과 제거 그리고 동역학적인 과정을 이해하는데 중요한 역할을 한다. (중략)

  • PDF

공기 중 농약 비산의 측정을 위한 광학 입자 측정기의 적용성 평가 (Applicability of Optical Particle Counters for Measurement of Airborne Pesticide Spray Drift)

  • 김락우;홍세운
    • 한국농공학회논문집
    • /
    • 제61권5호
    • /
    • pp.79-87
    • /
    • 2019
  • With desires for safe food, there is growing concern that pesticide spray drift will expose people, plants, and the environment to pesticide residue and potential negative effects thereof. For highly efficient, safe spray application, technologies for measuring the spray drift should be developed and improved with some urgency. This study investigated the applicability of two optical particle counters (OPCs), which are mostly used to measure airborne particle mass concentration, for measurement of airborne pesticide spray drift. Experiments were conducted in a controlled laboratory and an ash tree orchard to evaluate the handiness and accuracy of two OPCs, OPC 1 and OPC 2. The experimental results indicated that the OPC 1 was better applicable to the measurement of spray drift in the field while the use of the OPC 2 was limited due to its narrow range of measurable droplet sizes. The readings of the OPC 1 produced highly accurate results ($R^2=0.9637$) compared to the actual spray drift. For better application of OPCs, this study suggests the OPCs should be positioned properly to inhale spray droplets of the appropriate size and concentration.