• 제목/요약/키워드: optical diameter

검색결과 774건 처리시간 0.032초

Optical Design of an Off-axis Five-mirror-anastigmatic Telescope for Near Infrared Remote Sensing

  • Li, Xing Long;Xu, Min;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.343-348
    • /
    • 2012
  • This paper described an off-axis five-mirror-anastigmatic telescope. It is composed of three aspheric surfaces and one spherical surface while the third mirror and fifth mirror have the same parameters at the same place. This configuration is useful for having wide field of view. The strip full field of view for the near infrared telescope is $20^{\circ}{\times}0.2^{\circ}$. The entrance pupil is located in front of the first mirror. There is an intermediate image between the second mirror and the third mirror. The entrance pupil diameter is 100 mm and the effective focal length is 250 mm. The spectral range is $0.85-1.75{\mu}m$. The pixel pitch is $15{\mu}m$. The image quality is near the diffraction limit. Some methods were used to restrain the stray light such as a field stop near the intermediate image, the baffle, the narrow-band pass filter and a stop in front of the focal plane.

납땜 검사용 정밀 광학 장치 개발과 응용 (Development of precision optical system and its application)

  • 고국원;조형석;김재선;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.36-39
    • /
    • 1997
  • In this paper, we described an approach to design of precision optical system for visual inspection of solder joint defects of SMC(surface mount components) on PCBs(Printed Circuit Board). The illumination system, consisting of three tiered LED lamps and one main camera and four side view camera, is implemented to generated iso-contour on the solder joint according to gradient of the soldered surface. We analyze LED design parameter such as incident angle, diameter of LED ring, and so on to acquire uniform illumination.

  • PDF

구경 1 m 정밀 비구면 연마기 제작 (Fabrication of a Polishing Machine for 1 m Diameter Aspheric Surface)

  • 이원용;임동건;이재협;이회윤;송재봉;이윤우;이인원
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.36-37
    • /
    • 2002
  • 위성용 천문 망원경의 개발에 있어 광학계는 대구경화되고 회절한계능의 품질이 요구되고 있다. 한국표준과학연구원에서는 위성용 카메라를 위한 지름 1 m 의 비구면 거울의 제작기술을 확보하고자 하는 연구가 진행 중이다. 현재 지름 600 mm 의 비구면 연마기를 확보하여 테스트 중에 있으며, 지름 1m 비구면 가공을 위한 연마기를 제작 중에 있다. 비구면 가공을 위해서는 측정기술 또한 중요하다. (중략)

  • PDF

Sub-micron의 이온빔 직경을 가지는 축대칭 정전렌즈의 성능 해석 및 개선 (Performance Analysis and Modifications of Axi-Symmetric Electrostatic Lens for Sub-Micron Ion Beam System)

  • 이종현;배남진;김보우
    • 대한전자공학회논문지
    • /
    • 제26권9호
    • /
    • pp.1348-1358
    • /
    • 1989
  • We analyzed electrostatic lens with axi-symmetic configurations using the analytic equation for a single apertured lens. The developed computer code afforded to estimate ion optical properties such as ion trajectories, aberrations and ion beam diameters, and was found to have advantages of a shorter calculation time. The calculated ion optical properties for several types of electrostatic lens were in good agreement with Burghard's ones and it was seem that 20% reduction of ion beam diameter could be obtained by the change of aperture diameters.

  • PDF

광양자테 레이저의 선폭 특성 (Linewidth characterics of the PQR Lasers)

  • 김종삼;김준연;반노익;임권섭;류유신;배중우;권오대
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 하계학술발표회
    • /
    • pp.256-257
    • /
    • 2001
  • We measured the linewidth (FWHM) changes of the PQR laser against the diameter of the devices and the injection currents. We report the linewidth narrowing with increasing the PQR currents. A rough estimate of the line width behavior shows an inverse proportionality to the cavity length. The spectrum of $\frac{3}{4}$ circle cavity PQR laser is reported for the first time as well. The spectrum looks slightly different from that of the full circle device due to the structural distortion.

  • PDF

고출력 레이저-증폭기 계열의 Isolator 설계-(II) (Design of an Isolator of High Power Laser-Amplifier Series-(II))

  • 나승환
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.7-11
    • /
    • 1989
  • A Faraday rotator is designed with the HOYA FR-5 rotator glass. We find that traveling light rotates 45$^{\circ}$in the glass when magnetic field intensity is about 3.0$\times$105AT/m. The current of 2.7KA flowing in the coil of the 0cm diameter, 29cm long and 41 windings generates this magnetic field. A pulse forming network is designed for this current of 84 sec duration. The network is analyzed numerically to find the relevant circuit parameters for the flattest current waveform.

  • PDF

Development of Prototype Stylus Prototype for Large Optics Testing

  • Yang, Ho-Soon;Walker, David
    • Journal of the Optical Society of Korea
    • /
    • 제5권2호
    • /
    • pp.60-66
    • /
    • 2001
  • The authors discuss a prototype stylus profilometer designed to measure large optics. It consists of a low contact force type probe system, laser reference system, interferometric distance measurement system, and horizontal driving system. The probe contacts the surface ; the height and the horizontal distances of the measurement points are measured by the interferometer. The freely propagated laser beam provides the reference line during the measurement. The developed stylus profilometry shows only $\pm$60 nm of P-V error for the 157 mm diameter spherical mirror.

초정밀 단일점 다이아몬드 터닝을 이용한 비구면 금속 부반사경 가공 (Ultra-precision single point diamond turning (SPDT) on an aspheric metal secondary mirror)

  • Kim, E. D.;H. S. Yang;Kim, G-H.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.96-97
    • /
    • 2001
  • A 110 mm diameter aspheric metal secondary mirror for a test model of an earth observation satellite camera was fabricated by ultra-precision single point diamond turning (SPDT) . Without a conventional polishing process, the surface texture of R$\sub$a/=2.8 nm, and the form error of R$\sub$a/=0.05 λ has been stably achieved In a laboratory condition. (omitted)

  • PDF

Nanoparticle Contrast in Magneto-Motive Optical Doppler Tomography

  • Kim, Jee-Hyun;Oh, Jung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • 제10권3호
    • /
    • pp.99-104
    • /
    • 2006
  • We introduce a novel contrast mechanism for imaging superparamagnetic iron oxide (SPIO) nanoparticles (average diameter ${\sim}100nm$) using magneto-motive optical Doppler tomography (MM-ODT), which combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect the nanoparticles flowing through a glass capillary tube. A solenoid cone-shaped ferrite core extensively increased the magnetic field strength ($B_{max}=1\;T,\;{\Delta}|B|^2=220T^2/m$) at the tip of the core and also focused the magnetic force on targeted samples. Nanoparticle contrast was demonstrated in a capillary tube filled with the SPIO solution by imaging the Doppler frequency shift which was observed independent of the flow rate and direction. Results suggest that MM-ODT may be a promising technique to enhance SPIO nanoparticle contrast for imaging fluid flow.

유리 마이크로 광부품 어레이의 성형 (Molding of glass micro optical components)

  • 최우재;강신일
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.76-79
    • /
    • 2003
  • Glass molding is an advantageous method to manufacture glass micro optical components. However, it is difficult to make tungsten carbide core for glass molded micro optics way. We have developed novel method to fabricate tungsten carbide core for glass molding of glass micro optical components. Silicon masters were fabricated by micro machining. Tungsten Carbide cores were fabricated by forming, sintering and coating. Finally we fabricated glass molded V-groove with pitch of 192$\mu\textrm{m}$ and glass microlens way with lens diameter of 36∼225$\mu\textrm{m}$ by the present method.

  • PDF