• 제목/요약/키워드: optical clearing

검색결과 14건 처리시간 0.026초

청열약(淸熱藥)의 질내(膣內) 미생물(微生物)에 대(對) 항균효과(抗菌效果) (Antibiotic Effect of Heat-Clearing Medicinals on Vaginal Microorganisms)

  • 조정훈;장준복;이경섭;김경직
    • 대한한방부인과학회지
    • /
    • 제19권3호
    • /
    • pp.175-190
    • /
    • 2006
  • Purpose : This study was conducted to investigate the in vitro inhibitory effects of heat-clearing medicinal on common bacterias in gynecology. Methods : The heat-clearing medicinals ( Trichosanthis Radix, Sophorae Fructus, Phragmitis Rhizoma, Buddleiae Flos, Bambusae Folium, Anemarrhenae Rhizoma, Celosiae Semen, Gardeniae Fructus, Prunellae Spica, Sophorae Radix, Dictamni Radicis Cortex, Coptidis Rhizoma, Gentianae Scabrae Radix, Scutellariae Radix, Phellodendri Cortex) were used in this study. Staphylococcus aureus, MRSA, Candida albicans and Gardnerella vaginalis were used for vaginal pathogenic microorganisms. Streptococcus spp., Escherichia coli HB101, Lactobacillus gasseri were used for normal vaginal florae. We evaluated antibiotic effect by the optical density and the colony test. Results : The optical density and colony test showed that Celosiae Semen, Prunellae Spica, Scutellariae Radix and Phellodendri Cortex of herbs among heat-clearing medicinal had antimircobial effect. Celosiae Semen and Prunellae Spica had antimicrobial susceptibility and selective toxicity in MRSA. Scutellariae Radix and Phellodendri Cortex had antimicrobial susceptibility and selective toxicity in Gardnerella vaginalis. Conclusion : According to the above results, we could suggest that Celosiae Semen, Prunellae Spica, Scutellariae Radix and Phellodendri Cortex among heat-clearing medicinal be available to antimicrobial agent of vaginal pathogenic microbial species in vitro.

  • PDF

광산란 감소 물질에 의한 피부 각질층의 산란 감소 및 수화에 의한 각질세포의 물리적 특성에 대한 연구 (Optical Clearing Agent Decreases Scattering of Stratum Corneum and Modulates Physical Properties of Corneocytes by Hydration)

  • 전승현;염준석;안병준;박선규;이천구;이설훈;강내규
    • 대한화장품학회지
    • /
    • 제44권1호
    • /
    • pp.81-87
    • /
    • 2018
  • 본 연구에서는 각질층의 산란에 대한 새로운 분석 방법을 제공하고 광학에 사용되는 광산란 감소 물질들의 피부 각질층에서의 영향을 확인하였다. 각질층과 피부 구성 성분에 의해 산란되어지는 빛의 변화를 측정하기 위해 각질 테이프로 분리한 각질세포의 다크 필드 이미지 분석을 통해 다양한 광산란 감소 물질들의 각질층에서의 광산란 효과를 측정하고 분석하였다. 광산란 감소 물질의 처리 후 각질층의 물리적 특성(수분 함량, 케라틴 구조 및 두께) 변화는 FT-IR, 3D 레이저 현미경으로 관찰하였는데 화장품에서 보습제로 사용되는 단당류, 당 알코올, 환원당, 히알루론산 등은 광산란을 감소시킬 수 있었다. 그러나 광학에서의 탈수 현상과 달리 낮은 농도조건의 광산란 감소 물질은 각질층 케라틴 구조의 내부로 물의 침투를 향상시켜 각질층의 부피를 증가시키고 강성을 감소시키는 효과를 나타내었다. 이러한 광산란 감소 물질에 의한 각질층 각질세포의 수화 현상은 각질층의 광산란을 감소시켜 피부를 보다 투명하게 보이게 해 줄뿐만 아니라 지속적인 보습효과를 제공할 수 있는 각질층 타겟의 새로운 피부 개선 연구의 가능성을 확인할 수 있었다.

The Effect of an Optical Clearing Agent on Tissue Prior to 1064-nm Laser Therapy

  • Youn, Jong-In
    • Medical Lasers
    • /
    • 제10권3호
    • /
    • pp.146-152
    • /
    • 2021
  • Background and Objectives Although lasers have been widely applied in tissue treatment, the light penetration depth in tissues is limited by the tissue turbidity and affected by its absorption and scattering characteristics. This study investigated the effect of using an optical clearing agent (OCA) on tissue to improve the therapeutic effect of 1064 nm wavelength laser light by reducing the heat generated on the skin surface and increasing the penetration depth. Materials and Methods A diode laser (λ = 1064 nm) was applied to a porcine specimen with and without OCA to investigate the penetration depth of the laser light and temperature distribution. A numerical simulation using the finite element method was performed to investigate the temperature distribution of the specimen compared to ex-vivo experiments using a thermocouple and double-integrating sphere to measure the temperature profile and optical properties of the tissue, respectively. Results Simulation results showed a decrease in tissue surface temperature with increased penetration depth when the OCA was applied. Furthermore, both absorption and scattering coefficients decreased with the application of OCA. In ex-vivo experiments, temperatures decreased for the tissue surface and the fat layer with the OCA, but not for the muscle layer. Conclusion The use of an OCA may be helpful for reducing surface heat generation and enhance the light penetration depth in various near-infrared laser treatments.

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

Contrast Enhancement of Laser Speckle Contrast Image in Deep Vasculature by Reduction of Tissue Scattering

  • Son, Taeyoon;Lee, Jonghwan;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.86-90
    • /
    • 2013
  • Various methods have been proposed for enhancing the contrast of laser speckle contrast image (LSCI) in subcutaneous blood flow measurements. However, the LSCI still suffers from low image contrast due to tissue turbidity. Herein, a physicochemical tissue optical clearing (PCTOC) method was employed to enhance the contrast of LSCI. Ex vivo and in vivo experiments were performed with porcine skin samples and male ICR mice, respectively. The ex vivo LSCIs were obtained before and 90 min after the application of the PCTOC and in vivo LSCIs were obtained for 60 min after the application of the PCTOC. In order to obtain the skin recovery images, saline was applied for 30 min after the application of the PCTOC was completed. The visible appearance of the tubing under ex vivo samples and the in vivo vasculature gradually enhanced over time. The LSCI increased as a function of time after the application of the PCTOC in both ex vivo and in vivo experiments, and properly recovered to initial conditions after the application of saline in the in vivo experiment. The LSCI combined with the PCTOC was greatly enhanced even in deep vasculature. It is expected that similar results will be obtained in in vivo human studies.

조직투명화 기술을 통한 3차원적 접근 (Three-Dimensional Approaches in Histopathological Tissue Clearing System)

  • 이태복;이재왕;전진현
    • 대한임상검사과학회지
    • /
    • 제52권1호
    • /
    • pp.1-17
    • /
    • 2020
  • 조직병리학에서 현미경을 이용한 삼차원적 접근법은, 이차원 단면의 조직 슬라이드에서 박절 과정 중 부차적으로 발생하는 공간정보의 손실로 인하여 확인하기 어려웠던, 조직 내부 분자들의 공간적 배열, 상호결합, 구조적인 형태와 이들의 통합적인 공간적 정보체로서, 조직 내에 복잡하게 얽혀진 다양한 정보를 풀어내는데 있어서 복합적인 데이터를 제시하여 준다. 이광자 현미경(two-photon microscope)과 자동화된 보정환(correction collar)이 탑재된 고성능 대물렌즈의 개발과 같은 광학장비 영역의 발전은 조직투명화 과정을 거치지 않은 두꺼운 시료의 이미징에 있어서 광학적인 이론과 실체 사이에 존재하는 격차를 줄이는데 기여하였다고 할 수 있다. 하지만, 대물렌즈의 길어진 작동범위(working distance)와 최적화된 고강도 레이저의 사용으로 얻게 되는 이점들은 세포 내 각 구성요소의 굴절률(refractive index) 차이로 인하여 증가되는 빛의 분산(light scattering) 현상으로 인해 자연스럽게 감소하게 된다. 조직투명화 기술이 처음 등장하였던 초창기 시도되던 간단한 굴절률 일치화(RI matching) 기법에서부터 현대의 최첨단 통합 조직 투명화 기술에 이르기 까지를 관찰하여 볼 때, 형태학적인 변화없이 조직의 투명도를 높이는 것과, 내재적으로 또는 고정과정 중에 유래되어 혼합된 자가형광 노이즈를 효과적으로 제거하는것이 선명한 이미지를 얻기 위한 주요한 고려대상이라고 할 수 있다. CLARITY는 장비에 기반한 조직투명화 기법으로서 임상 조직병리 실험실에서 처리되는 동결절편과 포르말린에 고정된 검체 모두의 투명화를 위한 실험실 작업흐름(workflow) 통합 및 일상적인 실험절차와 호환이 가능할 것으로 보여진다.

High Optical Anisotropy Nematic Single Compounds and Mixtures

  • Gauza, Sebastian;Kula, Przemyslaw;Dabrowski, Roman;Sasnouski, Genadz;Lapanik, Valeri
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권1호
    • /
    • pp.2-5
    • /
    • 2012
  • We have designed, synthesized, and evaluated the physical properties of some high birefringence (${\Delta}n$) isothiocyanato biphenyl-bistolane liquid crystals. These compounds exhibit ${\Delta}n^-$ 0.4-0.7 at room temperature and wavelength $\lambda$=633 nm. Laterally substituted short alkyl chains and fluorine atom eliminate smectic phase and lower the melting temperature. The moderate melting temperature and very high clearing temperature make those compounds attractive for eutectic mixture formulation. Several mixtures based on those compounds were formulated and its physical properties evaluated.

500 Hz급 엑시머레이저의 반복동작특성 (Repetitive operation characteristics of 500 Hz class excimer laser)

  • 박홍진;이주희
    • 한국광학회지
    • /
    • 제7권3호
    • /
    • pp.232-237
    • /
    • 1996
  • 대기오염 원격측정용 LIDAR의 레이저광으로 사용하기 위해 반복율 500Hz급 엑시머 에리저를 개발하고 이의 고반복 에이저 출력특성, 레이저 가스의 유로구조와 CR특성을 조사하였다. 레이저 장치는 유선형의 가스유로, 주전극 직렬 UV 예비전리방식 등의 방법을 사용하고 컴팩트한 구조로 제작하여 가스 실용적을 10 liter 이하로 소형화하였다. KrF 레이저를 500Hz로 동작할 때의 최대출력은 53watt, 출력변동율은 .+-.6.7%, CR은 2.3, 방전체적은 2.0(H)*1.2(W)*56(L)=134$cm^{3}$ 이다. 이때 초기 출력에너지의 50%까지 출력이 감소할 때의 레이저가스의 수명은 3*$10^{6}$ shots이다.

  • PDF

1 kHz 고반복 엑시머레이저의 출력 특성 (Output characteristics of 1kHz high repetition rate excimer laser)

  • 박홍진;이주희
    • 한국광학회지
    • /
    • 제7권4호
    • /
    • pp.397-402
    • /
    • 1996
  • 레이저 가스를 하나의 횡류팬만으로 순환시키는 동심 원통형 구조의 소형 엑시머레이저를 개발하였다. 이 방치를 1kHz의 고속으로 반복동작시켰을 때 KrF 레이저의 평균출력은 56watt였다. 본 논문에서는 kHz급의 소형 엑시머레이저를 실현할 수 있는 설계 파라메터와 레이저 가스의 CR(Clearing Ratio)특성을 분석하였다. 평균출력 56watt일 때 레이저 효율은 1.2%, CR은 2.97, 출력변동율 .+-.9%이다. 이때 레이저 가스용적은 10 liter이고 방전체적은 1.8(높이)*1.2(폭)*30(길이)=64.8$cm^{3}$이다.

  • PDF

폴리{1-(콜레스테릴옥시카보닐알카노일옥시)에틸렌}들의 열 및 광학 특성 (Thermal and Optical Properties of Poly{1-(Cholesteryloxycarbonylalkanoyloxy)ethylene}s)

  • 정승용;마영대
    • 폴리머
    • /
    • 제33권2호
    • /
    • pp.144-152
    • /
    • 2009
  • 폴리{1-(콜레스테릴옥시카보닐알카노일옥시)에틸렌}들(PCALEn, n=2$\sim$8,10, 유연격자중의 메틸렌 단위들의 수)의 열 및 광학 특성을 검토하였다. 모든 동족체들은 좌측방향의 나선구조를 지닌 단방성 콜레스테릭 상들을 형성하였다. n=2 혹은 10인 PCALEn은 $3{\leq}n{\leq}8$인 PCALEn과 달리 콜레스테릭 상의 전 온도구간에서 반사색깔을 나타내지 않았다. 이러한 사실은 콜레스테릴 그룹에 의한 나선의 비틀림력은 콜레스테릴 그룹과 폴리에틸렌 사슬을 연결하는 유연격자의 길이에 민감하게 의존함을 시사한다. 유리전이온도들은 n이 증가함에 따라 낮아졌다. 액체 상에서 콜레스테릭 상으로의 전이온도들은 n이 7까지는 낮아지며 홀수-짝수 효과를 나타냈다. 그러나, n>7인 동족체들의 전이온도는 거의 일정하게 되었다. 이러한 거동은 유연격자의 홀수-짝수의 변화에 기인한 곁사슬 그룹의 평균적인 형태변화의 견지에서 설명된다. 전이온도에서 관찰되는 엔트로피 증가의 변화도 동일한 관점에서 설명된다. PCLAEn에서 관찰되는 액정 상의 열적 안정성과 질서도 그리고 광학피치의 온도의존성은 셀룰로오스 트리(콜레스테릴옥시카보닐)알카노에이트들에 대해 보고된 결과들과 현저히 달랐다. 이들의 결과를 주사슬의 화학구조와 유연성 그리고 반복단위당의 메조겐 단위들의 수의 차이들의 견지에서 검토하였다.