• Title/Summary/Keyword: ophthalmic test

Search Result 279, Processing Time 0.028 seconds

The State and Problem of the Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 실태와 문제점)

  • Kim, Douk-Hoon;Hwang, Sun-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.249-258
    • /
    • 1998
  • This study was researched the state and problem of the soft contact Lens wear by the history and inverted microscopy. The results was as follows; 1. The first use of contact lens wear was the 15 years and the last use was the 26 years. The first age of most contact lens wear was the 19 years. 2. In the almost contact lens wearers, the first visual test was the optical shop. 3. At present, almost soft contact lens purchase the optical shop 4. At present, most contact lens wearer like a soft type. 5. At present, most soft contact lens were a domestic production, and some subjects were foreign country production, but some subjects were unknown. 6. After contact lens wear, most subjects don't known the corrected visual acuity, especially, almost people don't known the binocular visual acuity. 7. At present, on soft contact lens color, the teens like the non-color contact lens, twenties like the color contact lens, but thirties was not known. 8. On the advantage of soft contact lens knowledge, most teens and twenties were only one, thirties was unknown. 9. On the disadvantage of soft contact lens knowledge, most teens and thirties were only one, twenties were two. 10. On the side effect of soft contact lens wearer, teens was one, and twenties and thirties don't known. 11. On the main symptoms of soft contact lens wearer, total kinds were seven, On these kinds, most subjects were not symptoms, the next order was unknown on the symptom. But, On the symptoms, the main symptoms was the pain and dry eye. 12. At present, the research on the surface morphology of soft contact lens by inverted microscope, the lens repture, lens folding, foreign body immersion and etc were present. Above the study, most contact lens was soft lens, and the purchase was the optical shop, on the other hand, the knowledge of soft contact lens and visual acuity was few. As a results, On the practical problems of soft contact lens wear, the optician have to the soft contact lens treatment and aftercare by law and educational supporting.

  • PDF

Phoria Changes Caused by Lens Adaptation after Wearing of Horizontal Prism Lens and Spherical Lens (수평 프리즘렌즈와 구면렌즈 착용 후 렌즈적응에 의한 사위도의 변화)

  • Lee, Min Jae;Kim, Sang-Yeob;Wee, Sung-Hyun;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.53-59
    • /
    • 2016
  • Purpose: To investigate an individual phoria compensating effect by measuring the lens adaptation after wearing horizontal prism or spherical lenses at near. Methods: 103 subjects (63 males and 40 females) aged $22.43{\pm}2.07years$ participated for this study. Refractive errors of subjects were fully corrected, and subjects were classified into three groups; esophoria, orthophoria and exophoria. The adaptation test of prism and spherical lenses was performed immediately, 15 minutes and 30 minutes after wearing lenses with $OU\;2\;{\Delta}\;BO$ and S+1.00 D for an esophoria group and $OU\;2\;{\Delta}\;BI$ and S-1.00 D for orthophoria and exophoria groups, respectively. Each measured phoria was compared to phoria measured with fully corrected condition, and the phoria changing effects about both lenses was analyzed. Results: The mean of phoria by prism lenses significantly decreased for every group. The mean of phoria by spherical lenses also significantly decreased in orthophoria and exophoria groups. The esophoria group showed a decreasing tendency but has no significance. The decreased phoria value by prism lens was classified into three steps; 90~100%, 0~10% and 50% or more. According to results of individual distribution ratio, it was 5, 64 and 24 subjects at 30 minutes after wearing lenses, respectively. The decreased phoria value by spherical lens was classified into three steps; 90~100%, 0~10% and 50% or more. According to results of individual distribution ratio, it was 37, 53 and 41 subjects at 30 minutes after wearing lenses, respectively. The subjects having no phoria changed by both prism and spherical lenses were 37.9%. Conclusions: When prescribing to compensate the near horizontal phoria using prism or spherical lens, the pretest for lens adaptation should be taken before prescription.

Change of Phoria and Subjective Symptoms after Watching 2D and 3D Image (2D와 3D 영상 시청 후 나타난 사위도 및 자각증상의 변화)

  • Kim, Dong-Su;Lee, Wook-Jin;Kim, Jae-Do;Yu, Dong-Sik;Jeong, Eui Tae;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.185-194
    • /
    • 2012
  • Purpose: The changes of phoria and subjective asthenopia before and after viewing were compared based on 2D image and two ways of 3D images, and presented for references of 3D image watching and production. Methods: Change in phoria was measured before and after watching 2D image, 3D-FPR and 3D-SG images for 30 minutes with a target of 41 university students at 20-30 years old (male 26, female 15). Paired t-test and Pearson correlation between changed phoria and subjective symptoms which were measured using questionnaires were evaluated by before and after watching each images. Results: Right after watching 2D image, exophoria was increased by 0.5 $\Delta$, in distance and near, but it was not a significant level. Right after watching 3D image, exophoria was increased by 1.0~1.5 $\Delta$, and 1.5~2.0 $\Delta$, in distance and near, respectively when compared with before watching. In the significant level, exophoria tended to increase. Changes in near was increased more by 0.5 $\Delta$, compared with those in distance. Changes based on way of 3D-FPR and 3D-SG image were less than 0.5 $\Delta$, and there was almost no difference. In terms of visual subjective symptoms, eye strain was increased in 3D image compared with that in 2D image. In addition, there was no difference depending on way of image. In terms of Pearson correlation between phoria change and eye strain, as exophoria was increased, eye strain was increased. Conclusions: Watching 3D image increased eye strain compared with watching 2D image, and accordingly exophoria tended to increase.

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

The Effect of Color Filter on the Reading Ability in Teenager with Irlen-Syndrome (얼렌증후군에서 컬러필터가 읽기능력에 미치는 영향)

  • Lee, Dong-Joon;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.125-136
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the effect of improving read speed with color filter or without color filter to improve reading disorder of teenager who were diagnosed as Meares-Irlen syndrome through survey inspection with Meares-Irlen syndrome visual stress (MISViS) score. Methods: MISViS subjects were selected from screening survey MISViS results given above 2.13 in the clinical criteria scores (MISViS score). Reading speed were measured quickly and efficiently the rate of reading via test in which randomly ordered common words are read aloud during a minute. Each of the subjects were worn a filter of the lowest concentration in each color filter group composed of 15 groups. Results: MISViS score of MISViS group and control group were 2.57 and 0.66, respectively. Results of reading speed with filter and without filter in MISViS group were $102.27{\pm}27.86$ wpm and $118.87{\pm}26.99$ wpm (p=0.001), respectively, as well as were $132.93{\pm}6.88$ wpm and $133.43{\pm}6.64$ wpm (p=0.131) in the normal group. Associated with error changes with filter and without filter between two groups, skipping in MISViS Group were from $0.25{\pm}0.62$ times to 0 times (p=0.191), Errors were from $1.83{\pm}1.69$ times to $0.17{\pm}0.38$ times (p = 0.004) and, repetitions were 0. skipping in control group were 0 times, errors were from $0.21{\pm}0.43$ times to $0.07{\pm}0.27$ times (p=0.336) and, repetitions were from $0.14{\pm}0.36$ times to 0 (p=0.165). The filter of blue series chosen in MISViS group had higher percentage (40%), whereas, subjects in normal group were more likely to prefer the filter of gray color (29%). Conclusions: This study showed that MISViS score have been used as a significant diagnosis for Irlen syndrome screening. This study found that wearing suitable color filter for MISViS patients were useful to improve learning with regard to reading. Unique color filter selection for MISViS subjects must be carefully considered since fit color filter are different personally.

Effect of Visual Perception by Vision Therapy for Improvement of Visual Function (시각기능 개선을 위한 시기능훈련이 시지각에 미치는 영향)

  • Lee, Seung Wook;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.491-499
    • /
    • 2015
  • Purpose: This study was to examine how decline of visual function affects visual perception by assessing visual perception after improving visual function through visual training, and observing the change in the cognitive ability of visual perception. Methods: This study analyzes the visual perceptual evaluation (TVPS_R) of 23 children below age 13($8.75{\pm}1.66$) who have visual abnormalities, and improves visual function after conducting vision training (vision therapy) of the children. Results: Convergence increased from average $3.39{\pm}2.52{\Delta}$ (prism) to $13.87{\pm}6.04{\Delta}$ in the measurement of long-distance disparate points, and from average $5.48{\pm}3.42{\Delta}$ to $18.43{\pm}7.58{\Delta}$ in the measurement of short-distance disparate points. Short-distance diplopia points increased from $25.87{\pm}7.33cm$ to $7.48{\pm}2.87cm$, and as for accommodative insufficiency, short-distance blur points increased from $19.57{\pm}7.16cm$ to $7.09{\pm}1.88cm$. In the visual perceptual evaluation performed before and after improving visual function, 6 items except visual memory showed statistically significant improvement. By order of significant improvement, response gap was highest with $17.74{\pm}16.94$(p=0.000) in visual closure, followed by $15.65{\pm}17.11$(p=0.000) in visual sequential-memory, $13.65{\pm}16.63$(p=0.001) in visual figure-ground, $12.74{\pm}18.41$(p=0.003) in visual form-constancy, $6.48{\pm}10.07$ (p=0.005) in visual discrimination, and $4.17{\pm}9.33$(p=0.043) in visual spatial-relationship. In the visual perception quotient that added up these scores, the response gap was $15.22{\pm}8.66$(p=0.000), showing a more significant result. Conclusions: Vision training enables efficient visual processing and improves visual perceptual ability. It was confirmed that improvement of visual function through visual training not only improves abnormal visual function but also affects visual perception of children such as learning, perception and recognition.

The Effect of Long-Term Orthokeratology in Different Age Groups (장기간 굴절교정렌즈 착용자에서 연령군 별 굴절교정효과 비교)

  • Mun, Mi-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the effect of age in the response to long-term overnight orthokeratology (OK) lens wearing. Methods: Among volunteers, ninety-five healthy subjects who had no eye diseases and could wear OK contact lens at least for 8 hours every day were divided into three groups children, youngsters and young adults. Unaided logMAR visual acuity, refractive error, apical corneal radius, corneal asphericity and central corneal thickness were measured with different period; before and after one day, one week, two weeks, one month, three months and six months of OK lens wear. Paired student t-test, ANOVA analysis and Pearson correlation were used with a critical p value of 0.05 for statistical analysis. Results: All groups showed statistically significant (p<0.001) improvement in unaided visual acuity, a trend for flattening in the apical corneal radius, decrease in central corneal thickness and less prolate after OK lens wear. The child group showed significantly rapid change (p<0.001) in visual acuity, and apical corneal radius showed that they reached the targeted refractive change earlier compared with youngster and adult groups. The visual effect of OK lens was significantly related with the change in central corneal thickness after long-term OK lens wear, especially in child and youngster group, and central corneal thickness were highly correlated with the targeted refractive change. Conclusions: Visual acuity change is statistically correlated with the central corneal thickness change, which is highly correlated with targeted refractive change in the long-term orthokeratology and younger lens wearers showed a rapid response to OK lens wear, suggesting a reduced epithelial response with increasing age. The results found this study extends our understanding and development in the long-term orthokeratology.

  • PDF

A Comparative Study on the Effects of Wearing Reverse Geometry Lenses by Degrees of Myopia (근시정도에 따른 역기하렌즈 착용효과에 관한 비교 연구)

  • Yoon, Min-Hwa;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.265-272
    • /
    • 2012
  • Purpose: To compare the results on myopia correction with reverse geometry lenses, effects of wearing reverse geometry lenses were evaluated for the children with low-level and high-level myopia. Methods: The research investigated the corrective effects of having worn reverse geometry lenses for one week, one month, three months and six months on a total of thirty-six persons (sixty-two eyes) between the ages of seven and fifteen, divided into three groups by the degree of their myopia; nineteen eyes(Group One) with myopia of -2.00 D and under, twenty-eight eyes(Group Two) with myopia between -2.25 D and -4 D, and fifteen eyes(Group Three) with myopia of -4.25 D and above; as shown by changes in uncorrected vision and the degree of refraction in the corneal topography, and tested for statistical similarity among the pursued results. Results: After wearing reverse geometry lenses, Group One showed an improvement in vision of 0.5, from 0.45 to 0.95, after one week, and improvements to 0.91 after one month and 1.02 after three months but, after six months, the group's vision regressed to 0.95. Group Two showed an improvement in vision of 0.43, from 0.34 to 0.77, after one week of wearing and to 0.91 after one month, to 0.97 after three months and this was statistically maintained through the remainder of six months. Group Three showed an improvement in vision of 0.55, from 0.15 to 0.7, after wearing for one week, to 0.87 after one month and to 0.91 after three months but saw a regression to 0.86 after six months. The average Sim K (simulated keratometry reading) value for Group One started from $42.84{\pm}1.17D$ and decreased to $41.48{\pm}0.98D$ after one week of wearing and continued declining through three months before increasing during the remainder of six months. Group Two began from $42.91{\pm}1.57D$ and recorded $41.78{\pm}1.58 D$ after one week, continuing the decline through three months before increasing during the remainder of six months. Group Three began at $42.64{\pm}1.64D$ and showed its Sim K value decrease to $40.77{\pm}1.20D$ after one week of wearing, increase after one month and decrease after three months and continue the decline through the remainder of six months. Conclusions: From the results of this study, wearing reverse geometry lenses had myopia-correcting effects after one week of wearing. Although there were variations in the time for such effect to take place but myopia-correcting effects were evident in all test groups.

Analysis of Evaluation Methods for the Efficacy of Protein Removal Agents for Soft Contact Lens (소프트콘택트렌즈 단백질제거제의 효능 평가법 분석)

  • Byuna, Hyun Young;Sung, Hyung Gyeong;Won, Hye Lim;Shim, Ji In;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.51-57
    • /
    • 2014
  • Purpose: The present study was conducted to establish the experimental condition for the proper evaluation of protein removal efficacy when developing protein removal agents. Its protein removal efficacy was further analyzed and compared with the result from protein removal efficacy against protein deposition on contact lens to suggest the evaluation method for efficacy of protein removal agents. Methods: Protein digestibility assay presented in the Korean pharmacopoeia was selected to establish the evaluation method for efficacy of papain, pancreatin, subtilisin A and protease itself as a ingredient and protein removal tablets or solution containing those enzymes and find a suitable test conditions. Furthermore, the cleaning efficacy of commercially available protein removal tablets and solution on balafilcon A lens deposited with protein artificially was measured and the correlation between two evaluation methods was further analyzed. Results: When pancreatin itself and the product containing pancreatin was evaluated by protein digestibility assay, both reached 28 IU/mg, the standard value of protein digestibility suggested by the Korean pharmacopoeia. In case of protease and subtilisin A tested with trichloroacetic acid B solution, both of them met the enzyme activity level proposed by the manufacturers when they were evaluated by protein digestibility assay however, papain and subtilisin A tested with trichloroacetic acid A solution were not reached the enzyme activity level. Among protein removal agents, three products except a product containing pancreatin did not meet the enzyme activity value specified by the manufacturer when they were evaluated by protein digestibility assay. However, actual protein removal efficacy of three products except a papain-containing product on the lens was greater than 90% protein removal. In the case of papain-containing protein removal product, its effect was not measured by protein digestibility assay however, its actual protein removal efficacy on the lens reached 73.72%. Conclusions: From the results, it was confirmed that the efficacy of protein removal agents for contact lens should be evaluated by different method according to the type of proteolytic enzyme contained. That is, the protein removal agents containing pancreatin, protease and subtilisin A can be evaluated by protein digestibility assay and protein removal efficiency evaluation and the products containing papain can be effectively evaluated by only the evaluation method for protein removal efficiency employing the lens.

Effect of Overcorrection (-)Lens on Stereo-acuity and Angle of Deviation in Intermittent Exotropia (간헐외사시에서 과교정 (-)렌즈가 입체시 및 사시각에 미치는 영향)

  • Kim, Young Cheong;Park, Sang Woo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the effect of prescription of overcorrection (-) lens, which is the one of the non-surgical treatments, on stereo-acuity and angle of deviation in intermittent exotropia. Methods: Twenty four children with intermittent exotropia were enrolled from October 2011 to December 2011. The angle of deviation(${\Delta}$), stereo-acuity (arcsec), monocular and binocular visual acuity (BVA, LogMAR), control of exodeviation and fusional ability using Worth 4 dot test were evaluated at near (33 cm) and far (6 m), under the overcorrecting (-)lens of -1.00, -.00, and -.00 D. Results: As a baseline finding, the angle of exodeviation was $20.9{\pm}9.7$ at near and $23.0{\pm}7.5$ at far. The angle of exodeviation at near decreased to $18.5{\pm}10.0$ (p<0.01), $15.8{\pm}9.0$ (p<0.01), $14.0{\pm}9.1$ (p<0.01) compared with baseline angle of exodeviation at near, as increasing diopters of (-) lens from -.00 D, -2.00 D and -.00 D, respectively. The angle of exodeviation at far also decreased to $21.4{\pm}5.2$ (p=0.01), $19.6{\pm}6.3$ (p<0.01) compared with baseline, as increasing minus lens from -2.00 D and -3.00 D, respectively. However, BVA, control of exodeviation, fusional ability and stereo-acuity showed no significant decrease despite of increasing diopters of (-)lens. Conclusions: The prescription of overcorrection (-)lens is an effective therapeutic method in intermittent exotropia which can reduce the near and far angle of exodeviation, and binocular visual acuity and stereo-acuity maintained without significant decrease despite of application of overcorrection (-)lens.