• Title/Summary/Keyword: ophthalmic test

Search Result 279, Processing Time 0.019 seconds

A Clinical Study on Relation among Accommodative Amplitude, Response, and Facility in young adults (근시성 굴절부등에 대한 임상적 고찰)

  • Joo, Seok-Hee;Shim, Moon-Sik;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.121-125
    • /
    • 2009
  • Purpose: This study has been conducted to know the prevalence of anisometropia and corneal refraction, accommodative response of myopic anisometropia. Methods: The study subject were 67 persons who myopic anisometropia of at least 1.00D, from among 808 total subject without ophthalmic diseases history from age 5 to 89 and the test were used to examine with both eyes open-view autorefractometer (NvisionK-5001). Results: The case which anisometropia were 85(10.5%) persons and myopic anisometropia were 67(78.8%) persons among the anisometropia. Difference between higher myopic eye and lower myopic eye were -1.22D${\pm}$0.94 in spherical equivalent, -0.25D${\pm}$0.72 in accommodative response, 0.04D${\pm}$0.68 in corneal refraction. In addition, the same case of both eyes accommodative response were 33(49.3%) persons, the great case of lower myopic eye accommodative response were 25(37.3%) persons and the great case of higher myopic eye accommodative response were 9(13.4%) persons. Conclusions: Myopic anisometropia was not affected by corneal refraction and both eyes difference of spherical equivalent was less as compared with both eyes difference of accommodative response.

  • PDF

The Influence of Office Indoor Air Qualitys on the Dry Eye Symptom of Contact Lens Wearers (사무실 실내공기질과 콘택트렌즈 착용여부가 안구 건조증에 미치는 영향)

  • Kim, Dea Jong;Park, Moon Chan;Lee, Se Hoon;Kim, Hyun Uk;Lee, Wha Ja;Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.215-222
    • /
    • 2012
  • Purpose: This study was performed to investigate the influence of indoor air qualities of an office environment on dry eye syndrome for wearing contact lens and non-wearing contact lens. Methods: To study the effects of indoor air qualities on dry eye syndrome for seventy-one subjects, $CO_2$, temperature, humidity, TSP, PM10, HCHO were measured. Each subject was tested by a McMonnie's dry eye syndrome questionnaire, a Schirmer Tear Test-I (S.T.T-I), a Schirmer Tear Test-II with anesthetics (S.T.T-II), and Tear film break-up time (T.B.U.T) in the their offices. Results: There was significant relation between the indoor air quality and dry eye syndrome for wearing contact lens and non-wearing when TSP was over $200{\mu}g/m^3$, PM10 was higher than $86.7{\mu}g/m^3$ and Formaldehyde was over $0.4{\sim}1.0{\mu}g/m^3$. However, there was no significant effect on dry eye syndrome with $CO_2$ (p=.0146), temperature (p=0.074) and humidity (p=0.053). Conclusions: It was indicated that $CO_2$, temperature and humidity were no effect on dry eye syndrome in the office environment. However TSP, PM10, formaldehyde, and wearing contact lens were effect on dry eye syndrome. Therefore, the entire management of wearing contact lens and the individual evaluation of the indoor air quality are required.

The study on relation between ocular function and accommodative facility (시기능과 조절 용이성과의 관계 연구)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.375-380
    • /
    • 2005
  • To assess convergence and accommodation at a short distance, 92 selected subjects without any ocular diseases by apperatuses of visual chart(Shinnippon CT30) and phoropter(Shinnippon VT 10) at a short distance(40 cm) were tested upon MEM retinoscopy(Welch Allyn, USA). BELL retinoscopy(Welch Allyn, USA), binocular accommodative facility (${\pm}2.00$ D flipper. Bernell Co., USA), vergence facility(prism flipper, Bernell Co., USA). There were such test results as MEM retinoscopy(R/L)($+1.05{\pm}0.87/1.02{\pm}0.80$ D). BELL retinoscopy ($17.89{\pm}12.12/17.94{\pm}11.72cm$), binocular accommodative facility (R/G)($7.69{\pm}6.48cpm$). binocular accommodative facility(polaroid)($11.76{\pm}5.22cpm$), monocular accommodative facility(R/L) ($13.9{\pm}6.27/13.8{\pm}5.96cpm$), vergence facility($13.5{\pm}6.40cpm$).

  • PDF

The Relationship Fixation Disparity between Associated Phoria (주시시차와 각비정시의 관계)

  • Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • In order to have a comfortable vision without any asthenopia in work place, it is very necessary to make a complete binocular correction in addition to the perfect correction of refractive deficits. For this, At first, the exact understanding of the required corrective value of the existing angular ametropia(associated phoria) is needed. The fact likely seems fact that a correction of refractive deficits could not to be reached with single optotype, the corrections of angular ametropia(associated phoria) with single optotype is impossible. The reason is that a most ametropia(associated phoria) is accompanied with the fixation disparity. To make a perfect measurement of ametropia(associated phoria), at least, 3 kinds of optotype is essential. This fact could be explained by stating the fusional stimulus in the binocular refraction tests on each eye. If these types of three tests have not practical practice. The most of many cases may result in undercorrection.

  • PDF

Change of Fixation Disparity and Accommodation when the Fusion Contrast Varied (융합대비에 따른 주시시차와 조절의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: To study the change of fixation disparity and accommodation as fusion contrast is deteriorated. Methods: 16 subjects who had above 20/20 and stereopsis took part. Monocular and binocular refraction were done with Zeiss Polatest Classic whereas the critical angle for stereopsis was done with TNO. A computer programmed with Random-Dot stereogram and vernier test managed a precise change of the fusion contrast and exposure time. Results: The fixation disparity was influenced by reduction of fusion contrast and had tendancy to exophoria (p=0.0004), especially it is considerably higher when uncrossed disparity was shown to exophoric subjects. Although accommodation was not influenced by a change of fusion contrast (p=0.803), vernier acuity was influenced (p=0.0000). Conclusions: Exophoric trend arose as the fusion contrast was reduced, nevertheless there was no accommadative change.

  • PDF

Survey on the Refractive Status of Primary School Children with Subnormal Visual Acuity in Seoul (서울지역 초등학동 비정시안의 굴절상태에 대한 조사)

  • Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.65-69
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. This study was researched visual acuity test using objective and subjective methods. 1. The eye types were 90.3% positive for myopia, 3.1% for emmetropia, 4.9% hyperopia, 1.7% for mired astigmatism. 2. The abnormal refraction eyes were 58.6% positive for simple myopia, 29.9% for myopic compound astigmatism, 5.1% for my optic simple astigmatism and 1.9% for simple hyperopia, 1.9% for hyperopic compound astigmatism, 1.3% for hyperopic simple astigmatism, 1.3% for mixed astigmatism. 3. The axis of astigmatism were 85.7% for astigmatism with-the-rule, 9.3% for astigmatism against-the-rule, 5.0% for astigmatism oblique. 4. On total myopic spheric power. the -0.50

  • PDF

Effect of EEG Wave Type of Visual Cortex on Conjugate Movement of Eyeball according to Movement of Visual Target (시 표적의 이동에 따른 안구의 동향운동이 대뇌 시피질의 뇌파에 미치는 영향)

  • Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2002
  • This study was to investigate the effect of EEG wave type of visual cortex on conjugate movement of eyeball according to movement of visual target. Visual evoked potential(VEP) system used the Bio-Pag(production in USA) and recorded to 586 computer. The illumination of test room was 50lux and the visual target was red light dot of 3cm size. The results of dextroversion and levoversion as follows : The visual stimulation waves on the visual cortex have about 71% of delta wave, about 12% of beta wave, about 9% theta wave and about 6% of alpha wave respectively. The dextroversion and levoversion state was similar results on the histogram amplitude of EEG wave, frequency of EEG wave type, EEG wave style and phase diagram of amplitude. Expecially the histogram amplitude of EEG wave appeared almost the Gaussian shape and the phase analysis of amplitude of EEG wave was nearly linear shape. On the fast fourier transform of the amplitude and Hz, the frequency was almost low frequency under 20 Hz, and the dextroversion and levoversion shape was similar results.

  • PDF

The Change After Visual Training of Forced Vergence Fixation Disparity Curve (강제vergence 주시시차곡선의 시기능훈련 후의 변화)

  • Choi, Sun-Mi;Lee, Ki-Young;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.539-550
    • /
    • 2014
  • Purpose: This research was designed to figure out if there are changes based on types of vergence fixation disparity curve after optical correction and vision training to for people with steep slope of forced vergence fixation disparity curve and symptoms. Methods: For 30 subjects out of 91 subjects, who have steep slopes of fixation disparity curve examined with Wesson Fixation Disparity Card and symptoms about steep slope of fixation disparity curve, proper vision training was offered for 5 weeks. Results: After Vision training for 30 people with the symptoms of type I, II, III, IV for 5 weeks, slope of fixation disparity curve was significantly changed (p=0.013), and the results of binocular vision test and subjective symptoms were also significantly improved. Conclusions: Vision training can not only affect the change of fixation disparity curve, but also relieve the symptoms. Fixation disparity curve has lots of visual function information of the subject and can be suggested as a guideline for prescribing.

Assessment of Accommodative Facility in General Binocular Dysfunctions (양안시이상에 따른 조절용이의 평가)

  • Park, Sang-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.51-57
    • /
    • 2009
  • Purpose: The purpose of this study was to determine if monocular and binocular accommodative facility tests would be useful in diagnosing general binocular dysfunctions. Methods: 95 symptomatic children, who were selected from comprehensive vision tests, were classified into four groups (29 subjects with accommodative dysfunctions, 28 subjects with vergence dysfunctions, 25 subjects with combined accommodative and vergence dysfunctions, 13 subjects with normal binocular functions). Monocular and binocular accommodative facility was measured with ${\pm}$2.00 D flipper lenses. Results: Statistical analysis revealed that binocular accommodative facility measurement was significantly lower than monocular accommodative measurement in the vergence dysfunction group (p<0.01). However, there were no differences between monocular and binocular accommodative facility measurements in the group of accommodative or combined accommodative and vergence dysfunction (p>0.05). In addition, subjects with general binocular dysfunctions performed significantly poorer than subjects with normal binocular function on monocular and binocular accommodative facility (p<0.000). Conclusions: As a result of this study, monocular and binocular accommodative facility test, which could differentiate dysfunction from normal as well as between dysfunctions, indicated useful means for diagnosis of general binocular dysfunctions.

  • PDF

A Study for Exact Spherical Diopter by Cross Cylinder Lens and Red·Green Card Method (크로스 실린더법과 적·녹검사를 이용한 정밀구면 굴절력에 관한 고찰)

  • Yoon, Kyounghan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.39-43
    • /
    • 1999
  • In this study, It obtained results that the exact spherical diopter to practice test by using Cross cyliner lens and Red Green Card method. In the test used to the 1750 eyes of middle and high school students. The results was as follows ; 1. Using Cross cylinder lens method, I tested a exact spherical diopter after accommodation. At -0.25 Dptr the ratio of spherical Dptr error limits were measured as 58% and at -0.75 Dptr they were oppeared as 1%, at -1.00 Dptr they are not measured. In this method, the error limits of exact spherical Dptr was 91% from 0 Dptr to -0.25 Dptr. 2. Using Red Green Card method, they were measured as 45% at -0.25 Dptr. and measured as 20% at -0.50 Dptr. From the result of these test, Cross cylinder lens method was a better detailed method than Red Green Card method.

  • PDF