• Title/Summary/Keyword: ophthalmic optics

Search Result 1,222, Processing Time 0.02 seconds

Effects of Volunteering Participation Motivation on Major Satisfaction and Continuance Willingness in Ophthalmic Optics Students

  • Cho, Seonahr;Kwak, Jinkyu
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.71-81
    • /
    • 2020
  • This study is intended to determine the effects of volunteering participation motivation on major satisfaction and continuance willingness in ophthalmic optics students. To achieve this, a survey was empirically carried out to ophthalmic optics students. The research findings showed that self-development among participation motivation factors had a significant effect on major satisfaction and continuance willingness, leisure on continuance willingness, and major satisfaction on continuance willingness in the relationship between the effects of volunteering participation motivation on continuance willingness and major satisfaction in ophthalmic optics students, respectively, adopting 3 hypotheses. On the other hand, leisure had no significant effect on major satisfaction, interpersonal exchange on major satisfaction, and interpersonal exchange on continuance willingness, respectively, rejecting 3 hypotheses. Which suggest that the high self-development willingness of college students as a factor of college volunteering participation motivation causes them to have pride and specialization in their major. Consequently, pride and specialization in major cannot only increase an understanding of personality and major, but maintain a positive attitude, leading to a long-continuous willingness, not a simple one-time service.

The correction principle of Aphakia using the Intraocular Lens (안내렌즈를 이용안 무수정체안의 교정원리)

  • Kim, Bong-Hwan;Kim, Tae-Hyun;Lim, Hyeon-Seon;Ji, Taek-Sang;Ko, Jung-Why
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.339-345
    • /
    • 2005
  • In this paper, we studied the principle that correct the emmetropia to the aphakia using intraocular lens. At present, in an ophthalmic clinic, I.O.L which is using for correction of the vision clinically has presented how to prescribe more accurately by using optical method. To correct the Aphakia for the emmetropia, we considered that the basic cause of Ametropia was the refraction and the axial length. The correction principle is made equal to the Back Focal Length(BFL) and the vitreous length from lens to retina. For the confirmation of the correction principle, we used the Gullstrand number I eye model in emmetropia. For the myopia and hyperopia, we used the clinical data and replaced crystalline lens with intraocular lens.

  • PDF

A Comparative Study of Ophthalmic Spectacle Lenses Standards (시력보정용 안경렌즈의 규격에 관한 비교 고찰)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.397-415
    • /
    • 2004
  • This study surveyed differences among KS, ISO, JIS and ANSI ophthalmic spectacle lenses standards. These standards applied to several lenses that were in common currency and we checked over problems and improvements in KS. KS corresponded to ISO, for the most part, and ANSI, partly. But terms, definitions, progressive power lenses standards, UV transmittance and base curves clauses did not exist in KS. There was no differences between nominal data and actual data in important clauses estimation-minimum requirements on refractive power, tolerances on the size of lenses, material and surface quality. But tolerances of thickness, base curves, UV and visible transmittance values were not existing, there were differences among several ophthalmic spectacle lenses in the test of these clauses. These requirements will be needed for better and more comfortable vision.

  • PDF

The Analysis of Binocular Vision Function by measuring Accommodative Convergence(AC/A) (조절성 폭주비(AC/A) 측정에 의한 양안시 기능 분석)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 2005
  • Accommodation and convergence is combination movement which is closely connected with each other. When one of them is stimulated, both of functions occur at the same time. Specially, the convergence by the accommodation's stimulation is called as accommodative convergence. That has excess or deficiency according to refraction state of eye. This study was performed by using both of Gradient method and Heterophoria method to 41 adults who have no any ophthalmic disease. 1. As the result of investigation about the distribution of heterophoria at distance, there were orthophoria of 5 subjects, exophoria of 32 and esophoria of 4. Exoporia occupied at the hightest rate. The distribution of heterophoria at near cover a wider range more than at distance. 2. When we measured the horizontal heterophoria amount in the state of relaxation of accommodation power of lens, exophoria amount increased in case of 38 subjects. 3. The person who has $4{\sim}6{\Delta}/D$ which conform to normal AC/A ratio occupied 27 subjects(66%) in Heterophoria method and 16(39%) in Gradient method, respectively.

  • PDF

Relationship between Uncorrected Visual Acuity and Refraction of the Children and Teenagers (소아, 청소년의 나안시력과 굴절이상의 상관성 분석)

  • Kim, Sang-Moon;Shim, Hyun-Seok;Shim, Jun-Beom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.173-178
    • /
    • 2013
  • Purpose: This study is to predict refractive errors according to uncorrected visual acuity using uncorrected visual acuity of the first glasses wearers. Methods: For 886 children who visited an ophthalmic clinic, subjective refraction was carried out with maintain refraction (MR) and cycloplegic refraction (CR), and objective refraction was carried out using auto-refractometer. Uncorrected visual acuity and corrected visual acuity were tested using on a trial lens and a Han's visual acuity chart. Results: In correlation between with the uncorrected visual acuity and refractive the myopia was the highest (r=0.774) and followed by hyperopia (r=0.670), simple astigmatism (r=0.623), simple with-the-rule astigmatism (r=0.604)and simple against-the-rule astigmatism (r=0.508). Conclusions: There were differences in the predictions between uncorrected visual acuity and refractive error according to the types of refractive error and astigmatism.

A Study for the Horizontal Induced Phoria in Spectacles Wearers (안경 장용자의 수평 유발 사위에 관한 연구)

  • Sung, Duk Yong;Lee, Won Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.85-91
    • /
    • 1996
  • Among the 110 glasses wearers, the hyperopic glasses wearers were 18(16.36%) persons and myopic glasses wearers were 92(83.64%) persons. The distance for optical centers was coincided to the pupillary distance in 9(8.18%) persons and discrepant in 101(91.82%) persons. Ophthalmic dispensing Pupillary Distance resulted from testing by the trouble error range(Germany RAL-915), unadopt spectacles had been wearers 52(51.49%) persons. The 65(64.56%) persons and 36(35.64%) persons showed the induced esophoria and the induced exophria, respectively. The maximal induced esophoria was 3.69 prism diopters and maximal induced exophoria was 3.68 prism diopters.

  • PDF

An inquiry into Institutionalization of Eye-Examiner in Korean Ophthalmic Clinics - Focusing on a Survey of Orthoptist Systems in Japan and English-Speaking World - (한국 안과병원의 검안전담인력 제도화에 관한 고찰 - 일본의 시능훈련사 제도와 영어권 국가의 Orthoptist 제도에 대한 조사를 중심으로 -)

  • Lee, Hyun Min;Jung, Seok Hun;Kim, Dal-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.87-95
    • /
    • 2009
  • Purpose: The aim of this study is to reveal necessity of orthoptist system in Korea, by comparative analysis between the orthoptist system of developed countries and the present condition in Korean ophthalmic clinics. Methods: Choosing 4 developed countries, we surveyed their education systems, license requirements and process, and service coverage. An inquiry into desirable Korean orthoptist system was added on the basis of the comparative survey. Results: The developed countries have systems in which professional orthoptists, who have got their licenses after official education, do the eye examination under the supervision of ophthalmologists. On the other hand in Korea, a problem is revealed that opticians play a role of eye-examiner in the ophthalmic clinics without any institutional support. Conclusions: The legalistic basis is quite needed in Korea that permit optometry graduates to be eye-examiners in the ophthalmic clinics, by introducing the orthoptist system.

  • PDF

An Optical Characteristic Research of a Netspec Lens (네츠팩 렌즈의 광학적 특성 연구)

  • Lee, Dong-Hee;Kim, Dae-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.85-90
    • /
    • 2003
  • A Netspec lens has the form having the 2-dimensional mesh coating on a general ophthalmic lens. It is known that it makes the ophthalmic image see more clearly, reducing the ophthalmic fatigue and that the transmittance of it for ultraviolet and infrared rays is lower. We need to prove this characteristic scientifically. So, in this study, we applied the Kirchhoff's scalar wave theory to the Netspec lens and induced a transmittance expression. And we made the program of which simulation can explain the transmittance effect of the Netspec lens. Also, we tried the interpreting about the result of the simulation. Finally, we have known that this simulation program can be used to adjust the transmittance of the light according to the wavelength.

  • PDF

The Research on the Optical Reliability of Spectacle Lens in Korea (국내 안경렌즈 광학적 요소 신뢰성 조사)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Purpose: This study is to evaluate reliability of geometrical optics properties of spectacle lenses by using ISO and the medical instrument standard of KFDA, which are being sold in Korea. Methods: We used samples of three hundred and ninety eight spectacle lenses of eight company in total. Refractive indices of each samples which were used in experiment were classified into three groups of medium index (1.55~1.56), high index (1.60~1.61) and extra high index (1.67). Results: Conformity of refractive power was 81.61% in total spectacle lenses. The results showed that thickness conformity 90%, appearance conformity 85.18%, size conformity 96.23% and optical center point conformity 99.50% in total. Conclusions: We found that they deviated from the permitting value in many spectacle lenses on refractive power. The results of errors on prism power, surface inspection and optical center point showed small values in total products. In experiment of lens size and thickness, the bulk of indication rates and conformities of samples deviated from the permitting errors.

  • PDF