• 제목/요약/키워드: operational calibration

검색결과 54건 처리시간 0.021초

HSPF 유역모델을 이용한 낙동강유역 수질 예측 (Operational Water Quality Forecast for the Nakdong River Basin Using HSPF Watershed Model)

  • 신창민;김경현
    • 한국물환경학회지
    • /
    • 제32권6호
    • /
    • pp.570-581
    • /
    • 2016
  • A watershed model was constructed using the Hydrological Simulation Program Fortran to predict the water quality, especially chlorophyll-a concentraion, at major tributaries of the Nakdong River basin, Korea. The BOD export loads for each land use in HSPF model were estimated at $1.47{\sim}8.64kg/km^2/day$; these values were similar to the domestic monitoring export loads. The T-N and T-P export loads were estimated at $0.618{\sim}3.942kg/km^2/day$ and $0.047{\sim}0.246kg/km^2/day$, slightly less than the domestic monitoring data but within the range of foreign literature values. The model was calibrated at major tributaries for a three-year period (2008 to 2010). The deviation values ranged from -31.5~1.6% of chlorophyll-a, -24.0~2.2% of T-N, and -5.7~34.8% of T-P. The root mean square error (RMSE) ranged from 4.3~44.4 ug/L for chlorophyll-a, -0.6~1.5 mg/L for T-N, and 0.04~0.18 mg/L for T-P, which indicates good calibration results. The operational water quality forecasting results for chlorophyll-a presented in this study were in good agreement with measured data and had an accuracy similar with model calibration results.

EFDC 수질모델을 이용한 영산강 수계 수질 예측 (Operational Water Quality Forecast for the Yeongsan River Using EFDC Model)

  • 신창민;민중혁;박수영;최정규;박종환;송용식;김경현
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.219-229
    • /
    • 2017
  • A watershed-river linked modeling system was developed to forecast the water quality, particularly weekly changes in chlorophyll-a concentration, of the Yeongsan River, Korea. Hydrological Simulation Program-Fortran (HSPF) and Environmental Fluid Dynamics Code (EFDC) were adopted as the basic model framework. In this study, the EFDC model was modified to effectively simulate the operational condition and flow of multi-functional weirs constructed in the main channel of rivers. The model was tested against hydrologic, water quality and algal data collected at the right upstream sites of two weirs in 2014. The mean absolute errors (MAEs) of the model calibration on the annual variations of river stage, TN, TP, and algal concentration are 0.03 ~ 0.10 m, 0.65 ~ 0.67 mg/L, 0.03 ~ 0.04 mg/L, and $9.7{\sim}10.8mg/m^3$, respectively. On the other hand, the MAE values of forecasting results for chlorophyll-a level at the same sites in 2015 range from 18.7 to $22.4mg/m^3$, which are higher than those of model calibration. The increased errors in forecasting are mainly attributed to the higher uncertainties of weather forecasting data compared to the observed data used in model calibration.

오차 보정 방법을 이용한 시간 영역 임피던스 측정의 정확도 개선 (Accuracy Improvement of Time Domain Impedance Measurement Using Error Calibration Method)

  • 노현승;;김양석;채장범;김병성
    • 한국전자파학회논문지
    • /
    • 제23권11호
    • /
    • pp.1315-1322
    • /
    • 2012
  • 주파수 영역 반사 진단법은 케이블의 임피던스 값을 측정하여 케이블의 고장점 위치를 진단한다. 전력 케이블 진단과 같이 험한 환경 또는 활성 상태에서의 진단을 위해서는 회로망 분석기보다 오실로스코프를 이용한 시간 영역 임피던스 측정이 널리 사용되고 있다. 그러나 시간 영역에서 임피던스 측정은 주파수가 증가하면 각종 기생 성분에 의해 임피던스 오차가 증가하여, 고장점 진단의 정밀도가 떨어진다. 본 논문에서는 시간 영역 임피던스 측정에 연산증폭기를 이용한 측정 시스템을 구현하고, 오차 보정 방법을 도입하여 좀 더 광대역에서 정확한 시간 영역 임피던스 측정을 수행하는 방법을 제시하고, 실제 케이블 측정 결과를 비교하여 제안된 방법을 검증한다.

검교정이 필요한 무기체계 정비장비의 구매 대수 결정을 위한 대기행렬이론 연구 (A study on decision number of maintenance equipment with calibration for weapon system with Queueing Theory)

  • 박정호;이익도;박연경;김두정
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.153-162
    • /
    • 2017
  • 무기체계는 기술의 발달로 인하여 급속도로 발전하고 있다. 이러한 발전덕분에 과거 무기체계에서 보지 못했던 고가의 첨단 전자장비들이 포함된 무기체계가 등장하게 되었다. 더불어, 고도의 기술이 적용된 무기체계의 운영 및 유지보수를 위한 장비유지예산 또한 증가되고 있다. 그러나 장비유지예산은 장비자산대비 그 비율이 감소추세에 있어, 효율적인 무기체계 운영에 어려움이 초래되고 있다. 이처럼 고비용 환경이 되고 있는 국방경영 및 감소되고 있는 장비유지예산을 고려하는 연구가 필요하다. 본 연구는 무기체계를 운영 및 유지보수 하는데 필요한 정비장비에 초점을 두고 있다. 최신 무기체계는 계측장비와 같은 정비장비를 활용하여 무기체계의 정렬 및 검교정 절차를 수행 후, 적정한 무기 성능이 유효하다고 볼 수 있다. 이러한 계측장비는 주기적으로 업체 외주정비(검교정 절차)를 하여 계측장비 자체의 정렬 및 상태 이상 유무를 확인해야 한다. 일반적으로 계측장비는 신뢰성이 입증된 해외업체의 계측장비를 구매하게 되고, 이러한 계측장비는 주기적으로 해외 외주정비를 받을 수밖에 없게 된다. 즉, 정비장비가 해외 외주정비를 진행하는 동안, 해당 무기체계는 성능에 대해 신뢰할 수 없으며 불가용 상태라고 볼 수 있다. 본 연구의 목적은 정비장비의 해외 외주정비로 인해 발생하는 무기체계의 손실비용과 정비장비의 구매 비용을 비교하여, 적절한 정비장비의 구매 대수를 제시하고자 한다. 본 연구의 결과가 효율적 작전 수행 보장에 기여할 것으로 판단되며, 전력 공백 문제를 해결 가능한 방안이 될 것이다.

Effect of model calibration on seismic behaviour of a historical mosque

  • Demir, Ali;Nohutcu, Halil;Ercan, Emre;Hokelekli, Emin;Altintas, Gokhan
    • Structural Engineering and Mechanics
    • /
    • 제60권5호
    • /
    • pp.749-760
    • /
    • 2016
  • The objective of the study is to investigate the effects of model calibration on seismic behaviour of a historical mosque which is one of the most significant Ottomon structures. Seismic analyses of calibrated and noncalibrated numeric models were carried out by using acceleration records of Kocaeli earthquake in 1999. In numerical analysis, existing crack zones on real structure was investigated in detail. As a result of analyses, maximum stresses and displacements of calibrated and noncalibrated numerical models were compared each other. Consequently, seismic behaviour and damage state of historical masonry Hafsa Sultan mosque was determined as more realistic in the event of a severe earthquake.

THE DEVELOPMENT OF IR-BASED VISIBLE CHANNEL CALIBRATION USING DEEP CONVECTIVE CLOUDS

  • Ham, Seung-Hee;Sohn, Byung-Ju
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.430-432
    • /
    • 2008
  • Visible channel calibration method using deep convective clouds (DCCs) is developed. The method has advantages that visible radiance is not sensitive to cloud optical thickness (COT) for deep convective clouds because visible radiance no longer increases when COT exceeds 100. Therefore, once DCCs are chosen appropriately, and then cloud optical properties can be assumed without operational ancillary data for the specification of cloud conditions in radiative transfer model. In this study, it is investigated whether IR measurements can be used for the selection of DCC targets. To construct appropriate threshold value for the selection of DCCs, the statistics of cloud optical properties are collected with MODIS measurements. When MODIS brightness temperature (TB) at 11 ${\mu}$ m is restricted to be less than 190 K, it is shown that more than 85% of selected pixels show COT ${\geq}$ 100. Moreover, effective radius ($r_e$) distribution shows a sharp peak around 20 ${\mu}m$. Based on those MODIS observations, cloud optical properties are assumed as COT = 200 and $r_e$ = 20 ${\mu}m$ for the simulation of MODIS visible (0.646 ${\mu}m$) band radiances over DCC targets.

  • PDF

싱글칩 마이크로프로세서에 의한 프로그래머블 2중 적분형 A/D 변환기의 개발 (A Design of Programmable Dual Slope A/D Converter by Single Chip Microprocessor)

  • 최규석;박찬원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.335-337
    • /
    • 1993
  • Offset voltage and drift characteristics of operational amplifier are critical factor to precision AID conversion System. In this study, a method is suggested to design the programmable A/D conversion system which has high resolution and low drift characteristics. First, hardware was designed to reduce the offset voltage of integrator and comparator, and analog switches are connected to reduce the drift characteristics of operational amplifier. And then, a calibration software technique was performed to obtain the stable data from A/D converter. The main advantage of our method is high precision A/D converter can be constructed with low cost and high confidence. Therefore proposed method is expected to be used in the industrial field where a high precision measurement is required.

  • PDF

범용 라디오 수신장비를 활용한 라디오존데 관측 (Radiosonde Observation Using General Purpose Radio Receiving Instruments)

  • 강현규;김주완;박민성;안상현
    • 대기
    • /
    • 제34권3호
    • /
    • pp.325-336
    • /
    • 2024
  • Radiosonde is an important in-situ profiling instrument that measures atmospheric temperature, moisture, and wind structure from the surface to the middle stratosphere. The operational radiosonde measurements are carried out more than twice (at 0000 UTC and 1200 UTC) daily at approximately 1,300 World Meteorological Organization (WMO) stations and play a pivotal role in daily weather forecasts. It also contributes to the monitoring of atmospheric structure by providing the key physical information like temperature and pressure, forming the backbone of atmospheric (re)analyses and numerical weather forecasts. Additionally, high-resolution radiosonde profiles are used for calibration and evaluation of satellite products. Despite these advantages, radiosonde measurements are mostly limited to operational uses due to the high initial cost of ground instrument setup required for data transmission and reception. This study outlines a cost-effective (roughly one-tenth of the operational cost) method for establishing the ground station and the necessary radiosonde measurement procedures, offering guidance for individual researchers or university-level instructors.

실시간 낙동강 흐름 예측을 위한 유역 및 수체모델 결합 적용 연구 (A Study on the Operational Forecasting of the Nakdong River Flow with a Combined Watershed and Waterbody Model)

  • 나은혜;신창민;박란주;김덕길;김경현
    • 한국물환경학회지
    • /
    • 제30권1호
    • /
    • pp.16-24
    • /
    • 2014
  • A combined watershed and receiving waterbody model was developed for operational water flow forecasting of the Nakdong river. The Hydrological Simulation Program Fortran (HSPF) was used for simulating the flow rates at major tributaries. To simulate the flow dynamics in the main stream, a three-dimensional hydrodynamic model, EFDC was used with the inputs derived from the HSPF simulation. The combined models were calibrated and verified using the data measured under different hydrometeological and hydraulic conditions. The model results were generally in good agreement with the field measurements in both calibration and verification. The 7-days forecasting performance of water flows in the Nakdong river was satisfying compared with model calibration results. The forecasting results suggested that the water flow forecasting errors were primarily attributed to the uncertainties of the models, numerical weather prediction, and water release at the hydraulic structures such as upstream dams and weirs. From the results, it is concluded that the combined watershed-waterbody model could successfully simulate the water flows in the Nakdong river. Also, it is suggested that integrating real-time data and information of dam/weir operation plans into model simulation would be essential to improve forecasting reliability.

The Overview of CEU Development for a Payload

  • Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Park, Jong-Euk;Chang, Young-Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.797-799
    • /
    • 2006
  • The Electro-optical camera subsystem as a payload of a satellite system consists of OM (optical module) and CEU(camera electronics unit), and most performances of the camera subsystem depend a lot on the CEU in which TDI CCDs(Time Delayed Integration Charge Coupled Device) take the main role of imaging by converting the light intensity into measurable voltage signal. Therefore it is required to specify and design the CEU very carefully at the early stage of development with overall specifications, design considerations, calibration definition, test methods for key performance parameters. This paper describes the overview of CEU development. It lists key requirement characteristics of CEU hardware and design considerations. It also describes what kinds of calibration are required for the CEU and defines the test and evaluation conditions in verifying requirement specifications of the CEU, which are used during acceptance test, considering the fact that CEU performance results change a lot depending on test and evaluation conditions such as operational line rate, TDI level, and light intensity level, so on.

  • PDF