• 제목/요약/키워드: operation strategy

Search Result 1,798, Processing Time 0.028 seconds

A Smooth LVRT Control Strategy for Single-Phase Two-Stage Grid-Connected PV Inverters

  • Xiao, Furong;Dong, Lei;Khahro, Shahnawaz Farhan;Huang, Xiaojiang;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.806-818
    • /
    • 2015
  • Based on the inherent relationship between dc-bus voltage and grid feeding active power, two dc-bus voltage regulators with different references are adopted for a grid-connected PV inverter operating in both normal grid voltage mode and low grid voltage mode. In the proposed scheme, an additional dc-bus voltage regulator paralleled with maximum power point tracking controller is used to guarantee the reliability of the low voltage ride-through (LVRT) of the inverter. Unlike conventional LVRT strategies, the proposed strategy does not require detecting grid voltage sag fault in terms of realizing LVRT. Moreover, the developed method does not have switching operations. The proposed technique can also enhance the stability of a power system in case of varying environmental conditions during a low grid voltage period. The operation principle of the presented LVRT control strategy is presented in detail, together with the design guidelines for the key parameters. Finally, a 3 kW prototype is built to validate the feasibility of the proposed LVRT strategy.

A Study on Improvement of Genetic Algorithm Operation Using the Restarting Strategy (재시동 조건을 이용한 유전자 알고리즘의 성능향상에 관한 연구)

  • 최정묵;이진식;임오강
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.305-313
    • /
    • 2002
  • The genetic algorithm(GA), an optimization technique based on the theory of natural selection, has proven to be relatively robust means to search for global optimum. It is converged near to the global optimum point without auxiliary information such as differentiation of function. When studying some optimization problems with continuous variables, it was found that premature saturation was reached that is no further improvement in the object function could be found over a set of iterations. Also, the general GA oscillates in the region of the new global optimum point so that the speed of convergence is decreased. This paper is to propose the concept of restarting and elitist preserving strategy as a measure to overcome this difficulty. Some benchmark examples are studied involving 3-bar truss and cantilever beam with plane stress elements. The modifications to GA improve the speed of convergence.

Complementary Power Control of the Bipolar-type Low Voltage DC Distribution System

  • Byeon, Gilsung;Hwang, Chul-Sang;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Jong-Yul;Kim, Kisuk;Ko, Bokyung;Kim, Eung-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.786-794
    • /
    • 2015
  • In this paper, a new power control strategy for the bipolar-type low voltage direct current (LVDC) distribution system is being proposed. The dc distribution system is considered as an innovative system according to the increase of dc loads and dc output type distribution energy resources (DERs) such as photovoltaic (PV) systems and energy storage systems (ESS). Since the dc distribution system has many advantages such as feasible connection of DERs, reduction of conversion losses between dc output sources and loads, no reactive power issues, it is very suitable solution for new type buildings and residences interfaced with DERs and ESSs. In the bipolar-type, if it has each grid-interfaced converter, both sides (upper, lower-side) can be operated individually or collectively. A complementary power control strategy using two ESSs in both sides for effective and reliable operation is proposed in this paper. Detailed power control methods of the host controller and local controllers are described. To verify the performances of the proposed control strategy, simulation analysis using PSCAD/EMTDC is being performed where the results show that the proposed strategy provides efficient operations and can be applied to the bipolar-type dc distribution system.

Seamless Transfer of Single-Phase Utility Interactive Inverters with a Synchronized Output Regulation Strategy

  • Xiang, Ji;Ji, Feifan;Nian, Heng;Zhang, Junming;Deng, Hongqiao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1821-1832
    • /
    • 2016
  • This study presents a strategy using the synchronized output regulation method (SOR) for controlling inverters operating in stand-alone and grid-connected modes. From the view point of networked dynamic systems, SOR involves nodes with outputs that are synchronized but also display a desirable wave shape. Under the SOR strategy, the inverter and grid are treated as two nodes that comprise a simple network. These two nodes work independently under the stand-alone mode. An intermediate mode, here is named the synchronization mode, is emphasized because the transition from the stand-alone mode to the grid-connected mode can be dealt as a standard SOR problem. In the grid-connected mode, the inverter operates in an independent way, in which the voltage reference changes for generalized synchronization where its output current satisfies the required power injection. Such a relatively independent design leads to a seamless transfer between operation modes. The closed-loop system is analyzed in the state space on the basis of the output regulation theory, which improves the robustness of the design. Simulations and experiments are performed to verify the proposed control strategy.

A Study on the Combustion Characteristics with Control Strategy and Injector Position Changes in a Lean-burn LPG Direct Injection Engine (연소제어 전략 및 분사기 위치 변경에 따른 직접분사식 초희박 LPG 엔진의 연소특성 연구)

  • Park, Cheolwoong;Park, Yunseo;Lee, Yonggyu;Oh, Seungmook;Kim, Taeyoung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.98-104
    • /
    • 2014
  • The technologies employing spray-guided type combustion system for ultra-lean combustion direct injection engine is focused as a promising technology for satisfying emission regulations and improving fuel economy. In the present study, control and design optimization of lean-burn LPG direct injection engine was carried out with control strategy and injection position changes. Inter-injection spark ignition strategy was applied and the effect of the strategy was assessed at relatively higher load operation condition than previous researches. In order to create richer mixture in the vicinity of spark plug electrode, relative distance between the dead-end of injector and the electrode of spark plug was changed.

Coordinated Control Strategy for Power Systems with Wind Farms Integration Based on Phase-plane Trajectory

  • Zeng, Yuan;Yang, Yang;Qin, Chao;Chang, Jiangtao;Zhang, Jian;Tu, Jingzhe
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • The dynamic characteristics of power systems become more and more complex because of the integration of large-scale wind power, which needs appropriate control strategy to guarantee stable operation. With wide area measurement system(WAMS) creating conditions for realizing realt-ime transient stability analysis, a new coordinated control strategy for power system transient stability control based on phase-plane trajectory was proposed. When the outputs of the wind farms change, the proposed control method is capable of selecting optimal generators to balance the deviation of wind power and prevent transient instability. With small disturbance on the base operating point, the coordinated sensitivity of each synchronous generator is obtained. Then the priority matrix can be formed by sorting the coordinated sensitivity in ascending order. Based on the real-time output change of wind farm, coordinated generators can be selected to accomplish the coordinated control with wind farms. The results in New England 10-genrator 39-bus system validate the effectiveness and superiority of the proposed coordinated control strategy.

Many-objective Evolutionary Algorithm with Knee point-based Reference Vector Adaptive Adjustment Strategy

  • Zhu, Zhuanghua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.9
    • /
    • pp.2976-2990
    • /
    • 2022
  • The adaptive adjustment of reference or weight vectors in decomposition-based methods has been a hot research topic in the evolutionary community over the past few years. Although various methods have been proposed regarding this issue, most of them aim to diversify solutions in the objective space to cover the true Pareto fronts as much as possible. Different from them, this paper proposes a knee point-based reference vector adaptive adjustment strategy to concurrently balance the convergence and diversity. To be specific, the knee point-based reference vector adaptive adjustment strategy firstly utilizes knee points to construct the adaptive reference vectors. After that, a new fitness function is defined mathematically. Then, this paper further designs a many-objective evolutionary algorithm with knee point-based reference vector adaptive adjustment strategy, where the mating operation and environmental selection are designed accordingly. The proposed method is extensively tested on the WFG test suite with 8, 10 and 12 objectives and MPDMP with state-of-the-art optimizers. Extensive experimental results demonstrate the superiority of the proposed method over state-of-the-art optimizers and the practicability of the proposed method in tackling practical many-objective optimization problems.

Aim at a Target Market of Small Groups The Case of the Brand 'Lonchel' Targeting Top Premiere Interior Market (소수의 표적시장을 선택하라: 최상위 프리미엄 인테리어 시장 지향 L사의 '론첼' 브랜드 사례)

  • Lee, Jaejin;Lee, Sung-Jun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.3
    • /
    • pp.97-110
    • /
    • 2022
  • The case study looks into the case of the "extreme" market segmentation strategy of company L with its top luxury windows and door brand "Lonchel". Company L has long enjoyed a leading position in the Korean windows and doors mass market. However, it went against their already well-established flagship brand and created a completely new one called "Lonchel", pursuing an extreme market segmentation strategy focusing on the small niche market of highest-income customers exclusively. The strategy has turned out to be successful and the company has gained long-lasting competitive advantages. In this vein this study analyzes the market environment in which the top-tier brand "Lonchel" appeared, the concept of the extreme positioning and the smallest viable market, the characteristics of target customers, the company's analysis of and response to them, and the analysis of products to meet their needs. The brand operation plan and promotion will be also reviewed. Through this, we intend to draw implications related to the extreme positioning strategy that a company may pursue in a target market of small groups of people.

The Fine Dust Reduction Effect and Operational Strategy of Vegetation Biofilters Based on Subway Station Passenger Volume (지하역사 내 승하차 인원에 따른 식생바이오필터의 미세먼지 저감효과와 운전전략)

  • Jae Young Lee;Ye Jin Kim;Mi Ju Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.13-18
    • /
    • 2023
  • A subway station is a prominent multi-purpose facility where the quantitative management of fine dust, generated by various factors, is conducted. Recently, eco-friendly air purification methods using air-purifying plants are being discussed, with the focus on biofiltration through vegetation. Previous research in this field has confirmed the reduction effects of transition metals such as Fe, which have been identified as harmful to human health. This study aimed to identify the sources of fine dust dispersion within subway stations and derive an efficient operational strategy for air-purifying plants that takes into account the behavior characteristics of fine dust within multi-purpose facilities. The experiment monitored regional fine dust levels through IAQ stations established based on prior research. Also, the data was analyzed through time-series and correlation analyses by linking it with passenger counts at subway stations and the frequency of train stops. Furthermore, to consider energy efficiency, we conducted component-specific power consumption monitoring. Through this study, we were able to derive the optimal operational strategy for air-purifying plants based on time-series comprehensive analysis data and confirm significant energy efficiency.

  • PDF

Small Break LOCA Analysis for RCP Trip Strategy for YGN 3&4 Emergency Procedure Guidelines (영광3, 4호기 비상운전지침용 원자로냉각재펌프 정지전략을 위한 소형냉각재상실사고 분석)

  • Seo, Jong-Tae;Bae, Kyoo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.203-215
    • /
    • 1995
  • A continued operation of RCPs during a certain small break LOCA may increase unnecessary inventory loss from the RCS causing a severe core uncovery which might lead to a fuel failure. After TMI-2 accident, the CEOG developed RCP trip strategy called “Trip-Two/Leave-Two” (T2/L2) in response to NRC requests and incorporated it in the generic EPG for CE plants. The T2/L2 RCP trip strategy consists of tripping the first two RCPs on low RCS pressure and then tripping the remaining two RCPs if a LOCA has occurred. This analysis determines the RCP trip setpoint and demonstrates the safe operational aspects of RCP trip strategy during a small break LOCA for YGN 3&4. The trip setpoint of the first too RCPs for YGN 3&4 is calculated to be 1775 psia in pressurizer pressure based on the limiting small break LOCA with 0.15 ft$^2$ break size in the hot leg. The analysis results show that YGN 3&4 can maintain the core coolability even if the operator fails to trip the second too RCPs or trips at worst time. Also, the YGN 3&4 RCP trip strategy demonstrates that both the 10 CFR 50.46 requirements on PCT and the ANSI standards 58.8 requirements on operator action time can be satisfied with enough margin. Therefore, it is concluded that the T2/L2 RCP trip strategy with a trip setpoint of 1775 psia for YGN 3&4 can provide improved operator guidance for the RCP operation during accidents.

  • PDF