• Title/Summary/Keyword: operation principle

Search Result 896, Processing Time 0.036 seconds

A Highly Efficient AC-PDP Driver Featuring an Energy Recovery Function in Sustaining Mode Operation

  • Kang, Feel-Soon;Park, Sung-Jun;Kim, Cheul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.100-108
    • /
    • 2002
  • A simple sustain driver employing an energy recovery function is proposed as a highly efficient driver of a plasma display panel. The proposed driver uses dual resonance in the sustaining mode operation: a main resonance between an inductor and an external capacitor to produce alternative pulses and a sub-resonance between an inductor and a panel to recover the energy consumption by the capacitive displacement current of the PDP. The operational principle and design procedure of the proposed circuit are presented with theoretical analysis. The operation of the proposed sustain driver is verified through simulation and experiments based on a 7.5-inch-diagonal panel with a 200 KHz operating frequency.

A Study on Permissible Operation Limit of Distributed Generation System in Distribution System (배전계통에서 분산전원 운전가능 범위에 대한 연구)

  • Jung, Won-Jae;Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.19-21
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case it is difficult to properly maintain the terminal voltage of low voltage customers by using only LDC(Line Drop Compensator). So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper clarifies the relationship between LDC voltage regulation principle and real, reactive power of DGS, and examines the permissible operation limit of the introduced DGS in distribution system which the voltage is controlled by LDC.

  • PDF

A Study on the Optimal Planning Model of Building Integrated Energy System's Components (건물용 종합에너지시스템 구성요소의 최적 투자모형에 관한 연구)

  • Suh, S.O.;Park, J.S.;Chang, S.C.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.797-799
    • /
    • 1997
  • This paper presents an operation and planning model of integrated energy systems which consist of small scale cogeneration systems, thermal accumulator, ice storage and electrical energy storage systems. In the proposed planning model, an optimization of total cost which contains investment, operation, thermal shortage and salvage costs has carried out with the maximum principle based on the lifetime of each system component and unit price per capacity. From this model, optimal investment capacity per annum can be determined during the studied periods using the marginal costs according to the operation characteristics of each system component.

  • PDF

An Analysis of the Dynamic Cutting Force on Face Milling Operation (正面 밀링 作業에서 動切削力의 解析)

  • 김희술;이상석;이병철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2268-2278
    • /
    • 1992
  • The vibratory modal for the face milling operation is assumed as a multi degrees of freedom system. The parameters of the system are determined based on the cutting experiment. From the relative displacements of this system the dynamic cutting forces were derived and simulated by the double modulation principle. The simulated cutting forces and measured cutting forces have a good agreement in time and frequency domains.

Selective Dual Duty Cycle Controlled High Frequency Inverter Using a Resonant Capacitor in Parallel with an Auxiliary Reverse Blocking Switch

  • Saha, Bishwajit;Suh, Ki-Young;Kwon, Soon-Kurl;Mishima, Tomokazu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.118-123
    • /
    • 2007
  • This paper presents a new ZCS-PWM high frequency inverter. Zero current switching operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. Dual duty cycle control scheme is used to provide a wide range of high frequency AC output power regulation that is important in many high frequency inverter applications. It found that a complete soft switching operation can be achieved even for low power setting ranges by introducing high-frequency dual duty cycle control scheme. The proposed high frequency inverter is more suitable for consumer induction heating(IH) applications. The operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

A Novel Power Frequency Changer Based on Utility AC Connected Half-Bridge One Stage High Frequency AC Conversion Principle

  • Saha Bishwajit;Koh Kang-Hoon;Kwon Soon-Kurl;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.203-205
    • /
    • 2006
  • This paper presents a novel soft-switching PWM utility frequency AC to high frequency AC power conversion circuit incorporating boost-half-bridge inverter topology, which is more suitable and acceptable for cost effective consumer induction heating applications. The operating principle and the operation modes are presented using the switching mode and the operating voltage and current waveforms. The performances of this high-frequency inverter using the latest IGBTs are illustrated, which includes high frequency power regulation and actual efficiency characteristics based on zero voltage soft switching (ZVS) operation ranges and the power dissipation as compared with those of the previously developed high-frequency inverter. In addition, a dual mode control scheme of this high frequency inverter based on asymmetrical pulse width modulation (PWM) and pulse density modulation (PDM) control scheme is discussed in this paper in order to extend the soft switching operation ranges and to improve the power conversion efficiency at the low power settings. The power converter practical effectiveness is substantially proved based on experimental results from practical design example.

  • PDF

A Study on Characteristics of Light Triggered Thyristor for Pulsed Power Application (펄스전력용 광점호 싸이리스터의 특성 연구)

  • Lee, Byung-Ha;Kim, Jin-Sung;Kim, Young-Bae;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.762-767
    • /
    • 2010
  • This paper describes characteristic of a light triggered thyristor investigated by experiment to adopt it into a main switch of a pulsed power unit. Triggering principle of the light triggered thyristor are referred with its structure and equivalent circuit. Operational principle and simulation result of a capacitive pulsed power circuit are explained. A variety of triggering conditions of triggering circuit and characteristics on turn-on, turn-off, voltage dividing in series operation, overvoltage protection function of the light triggered thyristor are investigated by experiments. Experimental result of 40 kJ pulsed power unit using the light triggered thyristor is presented.

Modeling and Analysis of Class D Audio Amplifiers using Control Theories (제어이론을 이용한 D급 디지털 오디오 증폭기의 모델링과 해석)

  • Ryu, Tae-Ha;Ryu, Ji-Yeol;Doh, Tae-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.4
    • /
    • pp.385-391
    • /
    • 2007
  • A class D digital audio amplifier with small size, low cost, and high quality is positively necessary in the multimedia era. Since the digital audio amplifier is based on the PWM signal processing, it is improper to analyze the principle of signal generation using linear system theories. In this paper, a class D digital audio amplifier based ADSM (Advanced Delta-Sigma Modulation) is considered. We first model the digital audio amplifier and then explain the operation principle using variable structure control algorithm. Moreover, the ripple signal generated by the hysteresis in the comparator has a significant effect on the system performance. Thus, we present a method to find the magnitude and the frequency of the ripple signal using describing function. Finally, simulations and experiments are provided to show the validity of the proposed methods.

Development of small-scaled Magnetically Levitated Train operation system (축소형 자기부상열차 운행 시스템 개발)

  • Sung, H.K.;Jung, B.S.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.256-258
    • /
    • 2004
  • It is not easy to apply new algorithm to the vehicle under driving test because the principle and moving characteristic of Magnetically Levitated Train(Maglev) developed in KIMM have been not easily analyzed yet. So, in this paper the small-scaled Maglev which can experiment economically and analyze moving-characteristic is proposed. Proposed small-scaled Maglev have the same principle and function as that of Maglev but it is smaller than real system at the ration of 1 to 7.

  • PDF

Blasting Utilizing Non-electric Detonator and Its Principle Planning and Operation (비전기 뇌관의 발파와 기본 설계 및 시공)

  • Choi Young-Cheon
    • Explosives and Blasting
    • /
    • v.22 no.4
    • /
    • pp.23-29
    • /
    • 2004
  • Non-electric detonator was developed to improve the blasting efficiency of electric detonator. It is increasingly utilized in surface and tunnel blasting due to its safety in external electric shock, precise delayed time, and decrease in blasting vibration and noise. The paper describes the detonating system of non-electric detonator, principle operating and planning methods, and case history so that it can be contributed to improve blasting technology.