• Title/Summary/Keyword: operation Modes

Search Result 815, Processing Time 0.035 seconds

Prediction of the Residual Stress for a Steel Plate after Roller Leveling - Part II : Integrated Model with Accelerated Cooling Model (롤러 레벨링 공정시 후판의 잔류응력 예측 - Part II : 가속냉각 모델을 통합한 모델)

  • Ye, H.S.;Hwang, S.M.
    • Transactions of Materials Processing
    • /
    • v.22 no.1
    • /
    • pp.11-16
    • /
    • 2013
  • Despite its importance the control of roller leveling has primarily relied on the operator's experience and on operation tables. In order to effectively eliminate various shape defects, the optimal leveling condition for a specific mode of plate deformation needs to be determined as well as a careful evaluation as to whether or not the condition is still appropriate for other modes or not. A numerical model, which considers both computation efficiency and accuracy, has been developed. The variations of residual stress are studied according to the entry and the delivery intermeshes, respectively. The camber deformation decreases linearly as the entry intermesh increases. In contrast the curl deformation does not vary directly with the entry intermesh. Therefore, the optimum intermesh values need to be determined in order to simultaneously minimize both the camber and the curl deformation.

Feasibility Study of the Decay Heat Removal Capability Using the Concept of a Thermosyphon in the Liquid Metal Reactor

  • Kim, Yeon-Sik;Sim, Yoon-Sub;Kim, Eui-Kwang
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.342-348
    • /
    • 2001
  • A new design concept for a decay heat removal system in a liquid metal reactor is proposed. The new design utilizes a thermosyphon to enhance the heat removal capacity and its heat transfer characteristics are analyzed against the current PSDRS (Passive Safety Decay heat Removal System) in the KAL IMER (Korea Advanced LIquid MEtal Reactor) design. The preliminary analysis results show that the new design with a thermosyphon yields substantial increase of 20∼40% in the decay heat removal capacity compared to the current design that do not have the thermosyphon. The new design reduces the temperature rise in the cooling air of the system and helps the surrounding structure in maintaining its mechanical integrity for long term operation at an accident. Also the analysis revealed the characteristics of the interactions among various heat transfer modes in the new design.

  • PDF

Clinical Evaluation of the Cardiac and Great Vessel Injury [17 cases] (심장 및 대혈관손상 17례에 대한 임상적 고찰)

  • 장동철
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.101-105
    • /
    • 1987
  • A clinical evaluation was performed on 17 cases of the cardiac and great vessel injuries above the subclavian vessel at the Department of Thoracic and Cardiovascular Surgery, Chungnam National University Hospital from April, 1980 to September, 1986. The results were as follows: 1. Sex distribution were 13 cases in male and 4 cases in female. In age range, second and third decades occupied in about 65% of total cases. 2. Modes of injury were penetrating wound is 14 cases and nonpenetrating wound in 3 cases. The stab wounds by knife were most frequent. 3. Time interval from injury to operation was mean 103 minutes. 4. Surgical approaches were performed with thoracotomy in 9 cases, median sternotomy in 3 cases and direct incision above the wound. 5. Sites of injury were heart in 10 cases and great vessel in 7 cases. The right ventricular injury was most common as 7 cases. 6. Operative procedures were performed with simple closure, vascular graft anastomosis and ligation. There was no postoperative death.

  • PDF

Performance Analysis of a Three-Phase Parallel Active Power Filter which Compensates PCC Voltage and the Unbalanced Loads

  • Lee, Woo-Cheol;Lee, Taeck-Kie;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.9-18
    • /
    • 2001
  • The performance analysis of a three-phase parallel active power filter that compensates PCC voltage and the unbalanced loads is presented in this paper. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. Firstly, it operates as a conventional active filter with reactive power compensation when PCC voltage is within the 15% voltage drop range. Secondly, it operates as a voltage compensator when PCC voltage is not within the 15% voltage drop range. And both APF and voltage compensator compensate asymmetries caused by nonlinear loads. Finally, two methods of detecting the negative sequence are reviewed, and the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rate at 10KVA.

  • PDF

A Soft Switching Boost Converter with High Voltage Gain Using a Single Switch (높은 승압비를 가진 공진형 소프트 스위칭 부스트 컨버터)

  • Park, Kun-Wook;Jung, Doo-Yong;Lee, Su-Won;Jung, Yong-Chae;Won, Chung-Yuen;Seo, Kwang-Duck
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.173-175
    • /
    • 2009
  • A dc/dc converter for low voltage of battery application and fuel cell system is required to step up and regulate the low and widely variable voltage. In this paper, we have proposed a soft switching boost converter with high voltage gain using a single switch. Through the theoretical analysis and experimental result, operation modes and characteristics of the proposed topology is verified.

  • PDF

NPC Type 3 Level Inverter Operation in Overmodulation Region (NPC형 3레벨 인버터 과변조영역운전)

  • Lee, Jae-Moon;Choi, Jae-Ho;Lee, Eun-Kyu;Yeom, Sang-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.194-197
    • /
    • 2007
  • This paper proposes a linearization technique for the 3 level NPC type inverter, which increases the linear control range of inverter up to the 6-step inverter. The overmodulation range is divided into two modes depending on the modulation index(MI), In mode I, the reference angles are derived from the Fourier series expansion of the reference voltage corresponds to the MI. In mode II, the holding angles are also derived in the same way. Therefore, it is possible to obtain the linear control and the maximized utilization of PWM inverter output voltage.

  • PDF

Dynamic Analysis and Optimum Design of Suspensions for Information Storage Devices (정보저장기기 서스펜션의 동특성 해석 및 최적설계)

  • Kim, Yun-Sik;Lee, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.576-581
    • /
    • 2002
  • The suspension is a structure that supports reading, writing head in information storage device. In order to develop the information storage device of high track density, it is necessary to study about the suspension. To satisfy operation condition of information storage device, the suspension shape is very important since it correlates to dynamic characteristics. Therefore, it is necessary to analyze the dynamic characteristics by using finite element analysis and to optimize the suspension of information storage device using size optimization and topology optimization. The suspension has various modes according to different kinds of frequency bandwidth. Sway mode and second torsion mode are especially critical among them. In this paper, we investigated method to improve bandwidth of sway and second torsion mode of HDD and ODD suspension by using size optimization and topology optimization.

  • PDF

Coarctation of the aorta: report of 2 cases (대동맥 축착증 -2례 보고-)

  • Kim, Byeong-Ju;Lee, Hong-Gyun
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.448-455
    • /
    • 1984
  • Coarctation of the Aorta is a congenital constriction of aorta of varying degree, usually located at or near the aortic ismuth with frequent associations of other cardiac anomalies. Various modes of surgical corrections, such as resection and end-to-end anastomosis, graft interposition, angioplasty using prosthetic patch or subclavian flap have been used according to the status of coarctation and age of the patient. We have experienced two cases of surgically treated coarctation of the aorta, one of which was preductal coarctation with hypoplastic aortic arch and ventricular septal defect in a 4 year old boy, and the other case was juxtaductal type with aortic regurgitation. Subclavian flap angioplasty with additional pulmonary artery banding procedure was done in the first case and wedge resection with end-to-end anastomosis and aortic valve replacement [St. Jude valve, 23mm] 20 days later of first operation in the other case. The first case developed massive tarry stool on 3rd POD, probably due to mesenteric arteritis with resultant bowl ecrosis, and expired the next day. Recovery was uneventful with the second case.

  • PDF

Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation (혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가)

  • 안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.

On Reliability Performance of Safety Instrumented Systems with Common Cause Failures in IEC 61508 Standard (공통원인고장을 고려한 안전제어시스템의 신뢰성 평가척도에 관한 고찰 : IEC 61508을 중심으로)

  • Seo, Sun-Keun
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.405-415
    • /
    • 2012
  • The reliability performance measures for low and high or continuous demand modes of operation of safety instrumented systems(SISs) are examined and compared by analyzing the official definitions in IEC 61508 standard. This paper also presents a status of common cause factor(CCF) models used in IEC 61508 and problems relating CCF modelling are discussed and ideas to solve these ones are suggested. An example with mixed M-out-of-N architecture is carried out to illustrate the proposed methods.