• Title/Summary/Keyword: operating type

Search Result 2,881, Processing Time 0.041 seconds

Effect of Fitness between Organizational Innovation and HRM Type on Performance (조직의 혁신방향과 인적자원관리의 기능별 전략 간의 적합성이 성과에 미치는 영향)

  • Kim, Jinhee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2019
  • This paper examines effect of fitness between innovation and HRM type on firm performance(quality competitiveness, operating profit). Data were extracted from the Korea Labor Institute's workplace panel survey(WPS) from 2015, and the analysis used 3,431 companies. To test the research model, analysis of variance(ANOVA). The model shows that full-innovation/commitment HRM type companies were significantly higher quality competitiveness, and operating profit than other companies. And low-level innovation/control HRM type companies were significantly lower quality competitiveness and operating profit than other companies.

A Step Type Dipole Antenna with Tapered Balun by CPW-fed to CPS (테이퍼드 발룬을 포함한 계단형의 다이폴 안테나 설계 및 구현)

  • Lee, Hyeonjin;Kim, Tea-Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.116-120
    • /
    • 2015
  • In this paper, a step type driver dipole antenna with a tapered balance and unbalance (balun) by a coplanar waveguide (CPW) to coplanar strip (CPS) transition is proposed. The proposed antenna consisted of step type driver, a CPW to CPS transition and tapered balun. The proposed antenna is realized the multi and wide resonate frequency band to introduce the step type driver and tapered balun. The step type driver is acted as a director too. This antenna could be more easily designed than the conventional printed quasi-Yagi dipole antenna. The operating frequency bandwidth was 650 [MHz] (2.65~3.3 GHz), 900 [MHz] (4.7~5.6 GHz) under a return-loss criterion of less than 10 dB. The measurements of the proposed antenna exhibited good results in the wideband operating frequency and radiation pattern. The proposed antenna can support wireless communications applications.

Characteristic improvement of the forward type high voltage pulse power supply for Lamp Type Ozonizer (램프형 오존발생기용 Foward형 고압 펄스전원장치의 특성개선)

  • Kim, Kyung-Sik;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Nam, Seung-Sik;Sim, Kwang-Yeal
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1117-1119
    • /
    • 2001
  • This paper describes the forward type pulse power supply using a Power-MOSFET in the view of commercialization. The principle of basic operating and the operating characteristics of the forward type pulse power supply are estimated by the switching frequency, coupling factor and duty ratio. It is shown that theoretical and experimental results are in good agreement by comparing simulation and experimental results when a lamp type ozonizer can be used as a load. Also, experimental results indicate that the discharge and ozone concentration characteristics of the manufactured pulse power supply is more improved compare to the conventional pulse power supply[5]. This proposed supply show that it can be practically used as a pulse power supply in various environment improvement facilities.

  • PDF

Operating Characteristics of Capacity Increase in a Flux-Lock Type Superconducting Fault Current Limiter (자속구속형 초전도 전류제한기의 용량증대를 위한 동작특성)

  • Nam, Gueng-Hyun;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Lee, Na-Young;Han, Tae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.200-202
    • /
    • 2006
  • We investigated the operating characteristics of a flux-lock type superconducting fault current limiters according to the number of the serial connection each the superconducting element at the additive polarity winding of a transformer. This SFCL consists of two coils wound in parallel on the same iron core, and the secondary coil is connected to the elements in series. Operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. It turns ratio between the primary and the secondary coils is 63:21. The analysis of voltage, current, and resistance in serial connection each element was performed to increase the applied voltage of flux-lock type SFCL. When the applied voltage was 200/$\sqrt{3}[V_{rms}]$ with three elements connected in seres, the peak value of the line current increased up to 26,24[A]. On the other hands, resistive SFCL increased up to 36.35[A], under the same conditions. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

  • PDF

Study on Measuring the Performance of an Air Tool Operating at 100,000 RPM Class (100,000 RPM급으로 회전하는 에어공구의 성능측정에 관한 연구)

  • Cho, Soo-Yong;Kim, Eun-Jong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.44-50
    • /
    • 2003
  • An experiment is conducted for measuring the performance of an air tool, which is operated at 100,000 RPM in an unloaded state with very low torque. A 551 kPa in gauge pressure is supply to the inlet of an air tool. An experimental apparatus is developed as a friction type dynamometer. Inlet total pressure, air flow rate, rotational speed and operating force are measured simultaneously. Torque, output power and specific output power are obtained with different rotational speeds. Those are compared with the experimental results which were obtained by a commercial dynamometer. However, no commercial dynamometers are available for measuring the torque above 30,000 RPM. In order to reduce the rotational speed, a reduction gear is applied between the air tool and the commercial dynamometer. Torque and power obtained by the commercial dynamometer show $55\%$ lower than those obtained by the developed friction type dynamometer, because the mass is added to the rotor of air tool for the braking system of the commercial dynamometer and power loss is generated by the reduction gear. From the compared results, the friction type dynamometer should be applied for measuring the performance of the air tool operating at low torque and high RPM.

An Experimental Study of Performance Characteristics on a Double Chamber Rotor Operated by High Pressure Air with Various Vanes (공압용 더블챔버 로터에서 베인개수에 따른 성능특성에 관한 실험적연구)

  • Cho, Chong-Hyun;Choi, Sang-Kyu;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.6 s.39
    • /
    • pp.54-62
    • /
    • 2006
  • An experiment about performance characteristics is conducted on a double chamber vane-type rotor. Three different rotors, which have 6, 8 and 9 vanes, are applied to the driver and various lift holes at the rear plate are used to increase the effective vane height. The inner diameter of a double chamber cylinder is ${\phi}27mm$, and the length of the cylinder is 65 mm. The maximum offset length between the rotor outer surface and the cylinder inner surface is 4.5 mm. In this study, specific output torques and powers are measured, and also noise and vibration are measured at the real operating situation. The operating torque on the double chamber is increased to 17% compared to the operating torque obtained at the single chamber which has the same size. The experimental results of noise and vibration show that the operating sound and vibration are directly related to the operating power generated by the double chamber rotor.

Efficiency Improvement of Uninterruptible Power Supply Systems (무정전 전원장치 효율 향상에 대한 연구)

  • Oh, Heun-Gil;Kwon, Jong-Won;Park, Yong-Man;Odgerel, Odgerel;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.288-290
    • /
    • 2006
  • An efficiency improving method for Uninterruptible Power Supply System(UPS) was developed by using OP-AMP based application circuits such as voltage detection device, current detection device and static switch control device. The efficiency improving algorithm was made by mixing the operating concepts of On-Line type UPS with the operating concepts of Off-Line type UPS. The UPS' inverter does not work if the UPS' output load current is not higher than the low load operating current which is about 0-30(%) of the UPS' output load capacity. The low load operating current is adjustable within the half of the UPS' output load capacity. If the UPS' output load current is rising over than the low load operating current, the UPS' inverter starts working and the inverter output power feeds to the loads of UPS. If UPS' input power breaks out while UPS' inverter does not operate because the load current is low, the inverter starts working within 4(ms) with excessive output voltage which is ${\pm}$8(%) of normal UPS' output voltage. Like these. UPS can continuously feeds power to it's load device and reduce power consumptions.

  • PDF

Off-Design Performance Analysis of a Counterflow-Type Cooling Tower (대향류형 냉각탑의 탈설계 성능해석)

  • 신지영;손영석;한동원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.191-198
    • /
    • 2002
  • Cooling tower design procedure was set up using conventional Merkel theory, The design data could be different depending on the characteristic curve that the engineer chose. It reveals that the consistent and reasonable criteria are required based on the exact information of the cooling tower Performance. In this study, an off-design performance analysis program for a counterflow-type cooling tower was developed and verified by comparing with experimental data. Also, the off-design performance with various operating conditions was analyzed.

Proposal and Analysis of Wavelength-Switchable Optical Fiber Filter Based on a Solc Type

  • Kim, Min-Wook;Jung, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.147-151
    • /
    • 2008
  • This paper proposes a new polarization-independent Sagnac birefringence loop structure-based multiwavelength-periodic filter and presents measurements and analysis of its spectrum. The filter can be used in several schemes by adjusting the orientation angles of two quarter waveplates and the operating characteristics in the reflection type are analyzed including dispersion and polarization mode dispersion at each principal axis. This filter has polarization-independent spectra but a polarization-dependent dispersion, consequently polarization mode dispersion whose values changes with operating schemes.

The Operating Characteristic Analysis of PM-type Magnetic Circuit Breaker (영구자석형 차단기 조작기의 동작 특성 해석)

  • Jun, Hee-Deuk;Woo, Kyung-Il;Kim, Byung-Taek;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.253-255
    • /
    • 2000
  • This paper describes the operating characteristic analysis of PM-type magnetic circuit breaker for electromagnetic field, electric circuit and mechanical motion problems. Transient calculations based up 2D finite element magnetic field solution including non-linearity of materials. Change of dynamic characteristic from eddy current in mover is quantified from FEM analysis.

  • PDF