• 제목/요약/키워드: operating temperature

검색결과 3,677건 처리시간 0.035초

Er-doped Superfluorescent Fiber Source with Thermally Stable Mean Wavelength

  • Park, Hee-Gap;Yun, Seung-Chul;Jin, Young-Jun
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.240-244
    • /
    • 2009
  • An Er-doped superfluorescent fiber source is designed and constructed with the double-pass forward configuration, which aims at high stability of its mean wavelength against temperature variation. As a result, thermal stability of mean wavelength better than 1 ppm is obtained against the temperature variation of ${\pm}5^{\circ}C$ around the optimum operating temperature. The optimum operating temperature can be tuned with the Er-doped fiber length and the pump power.

Numerical Prediction of Aviation Fuel Temperatures in Unmanned Air Vehicles

  • Baek, Nak-Gon;Lim, Jin-Shik
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권4호
    • /
    • pp.379-384
    • /
    • 2011
  • This paper performs numerical prediction of fuel temperature in the fuel tanks of unmanned air vehicles for both ground static non-operating and in flight transient conditions. The calculation is carried out using a modified Dufort-Frankel scheme. For this calculation, it is assumed that a non-operating vehicle on the ground is subjected to repeating daily cycles of ambient temperature with solar radiation and wind under 1%, with a 20% probability of hot day conditions. The energy conservation equation is used as the governing equation to calculate heat transfer between the fuel tank surface and the ambient environment. Results of the present analysis may be used as the estimated initial values of fuel temperatures in a vehicle's fuel tank for the purpose of analyzing transient fuel temperatures during various flight missions. This research also demonstrates that the fuel temperature of the front tank is higher than that of the rear tank, and that the difference between the two temperatures increases in the later phases of flight due to the consumption of fuel.

스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구 (Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

신경망을 이용한 판온예측모델내 공정상수 설정 방법 (A Computing Method of a Process Coefficient in Prediction Model of Plate Temperature using Neural Network)

  • 김태은;이해영
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.51-57
    • /
    • 2014
  • This paper presents an algorithmic type computing technique of process coefficient in predicting model of temperature for reheating furnace and also suggests a design method of neural network model to find an adequate value of process coefficient for arbitrary operating conditions including test conditons. The proposed neural network use furnace temperature, line speed and slab information as input variables, and process coefficient is output variable. Reasonable process coefficients can be obtained by an algorithmic procedure proposed in this paper using process data gathered at test conditons. Also, neural network model output equal process coefficient under same input conditions. This means that adquate process coefficients can be found by only computing neural network model without additive test even if operating conditions vary.

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

Nanomaterials for Advanced Electrode of Low Temperature Solid Oxide Fuel Cells (SOFCs)

  • Ishihara, Tatsumi
    • 한국세라믹학회지
    • /
    • 제53권5호
    • /
    • pp.469-477
    • /
    • 2016
  • The application of nanomaterials for electrodes of intermediate temperature solid oxide fuel cells (SOFC) is introduced. In conventional SOFCs, the operating temperature is higher than 1073 K, and so application of nanomaterials is not suitable because of the high degradation rate that results from sintering, aggregation, or reactions. However, by allowing a decrease of the operating temperature, nanomaterials are attracting much interest. In this review, nanocomposite films with columnar morphology, called double columnar or vertically aligned nanocomposites and prepared by pulsed laser ablation method, are introduced. For anodes, metal nano particles prepared by exsolution from perovskite lattice are also applied. By using dissolution and exsolution into and from the perovskite matrix, performed by changing $P_{O2}$ in the gas phase at each interval, recovery of the power density can be achieved by keeping the metal particle size small. Therefore, it is expected that the application of nanomaterials will become more popular in future SOFC development.

R134a 냉매용 초임계 히트펌프의 성능 특성 (Performance Characteristics of R134a Supercritical Heat Pump)

  • 최인수
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.60-65
    • /
    • 2014
  • In this paper, cycle performance analysis for heating capacity, compression work and COP of R134a supercritical heat pump is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature in the R134a supercritical heat pump system. The main results were summarized as follows : Superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature of R134a heat pump system have an effect on the heating capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. The prediction for COP of R134a supercritical heat pump have been proposed through multiple regression analysis.

고온/고압 하에서 물로 윤활되는 스테인레스 강의 마찰 특성 (Frictional characteristics of stainless steel lubricated with pressurized high temperature water)

  • 이재선;김은현;김지호;김종인
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.96-99
    • /
    • 2001
  • The fatigue life of support bearings is one of the most critical factors for the performance of a control rod driving mechanism. They are operated at high temperature and high pressure and especially lubricated with dramatically low viscosity water. The support bearing is made of standardized 440C stainless steel, and it supports thrust load including the weight of the driving system and external force. Friction and wear characteristics of this material operating under severe lubrication condition is not well known yet, although it is expected to be changed with respect to temperature and boundary pressure. So the friction characteristics are investigated in sliding conditions using the reciprocating tribometer which can simulate the operating conditions. Highly purified water is used as lubricant, and the water is heated up and pressurized. Friction farce on the reciprocating specimens is monitored by the load cells. The results of the experiments are presented in this paper.

  • PDF

역삼투 시스템을 이용한 감 과즙의 농축 (Concentration of Persimmon Juice by Revers Osmosis System)

  • 강현아;장규섭
    • 한국식품과학회지
    • /
    • 제29권2호
    • /
    • pp.279-283
    • /
    • 1997
  • 국내에서 과잉 생산되고 있는 감을 이용하며 제품화할 뿐만아니라 고품질화 기술 개발을 위하며 막분리 시스템을 적용하였다. 즉 역삼투법을 이용하여 감과즙을 농축시에 시간, 압력, 공급액의 온도 및 농도가감 과즙의 투과플럭스에 미치는 영향을 조사하고 제품의 성분을 분석하여 다음과 같은 결과를 얻었다. 감 과즙을 역삼투막을 이용하여 농축시에 공정온도가 높고 공정압력이 높을수록 투과유속이 증가하였으며, 온도의 영향보다는 공정압력의 영향이 더 큰것으로 나타났다. 또한 감 과즙의 농도변화에 따른 투과유속의 변화는 공정압력이 낮을수록 더 급격히 저하되었으며, 본 실험에 사용한 역삼투막의 농축한계 농도는 $30^{\circ}Brix$ 전후를 나타내었다. 본 시스템을 이용하여 감 과즙을 농축시에 당의 잔존율은 90% 이상이었으며 공정조건에 큰 영향을 받지 않았다. 또한 휘발성 성분의 잔존율은 60% 이상이었으며, 공급액의 온도가 낮고 공정압력이 높을 때 잔존율이 높게 나타났다.

  • PDF

저온동작용 $Co_{3}O_{4}$ 부탄가스 감지 소자(I) ($Co_{3}O_{4}$ butane gas sensor operating at low temperature (I))

  • 정진환;최순돈
    • 센서학회지
    • /
    • 제5권6호
    • /
    • pp.7-14
    • /
    • 1996
  • 저온에서 동작 가능한 센서를 개발하기 위하여 $Co_{3}O_{4}$ 후막 소자를 제조하였다. $Co_{3}O_{4}$ 분말은 질산코발트 수용액으로부터 침전하여 얻었으며 binder인 ethylene glycol과 혼합하여 알루미나 기판상에 후막을 인쇄하였다. 제조된 후막에 대해 binder 함량 및 열처리 조건에 따른 부탄가스의 감도 및 회복성을 조사하였다. 동작 온도 $250^{\circ}C$에서 15% ethylene glycol을 함유한 $Co_{3}O_{4}$ 분말을 $300^{\circ}C$ 에서 24시간 동안 열처리한 소자가 부탄가스에 대하여 최고의 감도를 나타내었다. 감도는 500ppm 부탄가스에 대하여 1.1 정도로, 동작 온도 $350{\sim}400^{\circ}C$에서 상용 $SnO_{2}$ 가스 감지 소자의 감도 $0.8{\sim}0.85$와 비교할 때 매우 높았다. 응답 특성은 매우 좋았으나 회복성은 나쁜 것으로 나타났다.

  • PDF