• 제목/요약/키워드: operating temperature

검색결과 3,680건 처리시간 0.028초

자동차용 기관의 냉각수 온도조절 최적화에 관한 연구(I) (A Study on the Optimum Cooling Water Temperature Control of an Automotive Engine(I))

  • 박경석;신진식;이경우
    • 오토저널
    • /
    • 제14권2호
    • /
    • pp.34-43
    • /
    • 1992
  • The purpose of this study is to consider the performance and exhaust characteristics in the practical engine according to the cooling water temperature change of engine and to set up the optimum cooling condition and to obtain the optimum operating condition of thermostat in the cooling system. In order to accomplish the purpose of this study, authors have used the following procedure. 1. This study is to investigate the influence of the cooling water temperature on the engine performance and the exhaust gas, authors regulated the cooling water temperature by using the special closing circuit and measured the concentration of exhaust gas by using the exhaust gas measuring system in the exhaust pipe. 2. This study carried out the experiment by regulating the opening degree of throttle valve and engine speed in the dynamometer and by changing the cooling water temperature, at the same time kept air-fuel ratio constant and made the spark ignition time MBT(Minimum spark advance for Best Torque) 3. This study measured the cooling water temperature by using the K-type thermocouple centring around the easy over-heated parts and by installing a special closing circuit. Therefore, in this study, authors intend to examine the influence of the cooling water temperature on the engine performance, exhaust gas and present the basic materials needed in the engine design including the optimum operating time control system for the cooling water temperature.

  • PDF

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

추진제 탱크내의 액체산소 온도상승에 대한 해석적 고찰 (Analytical Investigation on Temperature Rise of Liquid Oxygen in Propellant Tank)

  • 조남경;정용갑;김영목;정상권
    • 한국추진공학회지
    • /
    • 제9권3호
    • /
    • pp.25-37
    • /
    • 2005
  • 터보펌프 공급방식 발사체 추진기관은 공급 시작 시점에서부터 종료되는 시점까지 산화제 터보펌프 입구에서의 온도 요구조건을 충족시켜야 한다. 이러한 조건이 만족되지 못할 경우 터보펌프 입구에서 캐비테이션이 발생하여 펌핑(pumping) 성능이 저하되고, 심한 경우 펌프의 손상을 초래할 수 있다. 따라서 극저온 액체산소를 사용하는 액체로켓 추진기관에서는 액체산소의 온도 상승에 대한 적확한 예측이 필수적이다 본 논문에서는 탱크 내의 액체산소 온도상승과 관계된 탱크 내 해석 방법을 체계적으로 제시하였고, 부력동기 경계층 이론을 적용하여 터보펌프 공급방식 로켓 추진기관의 충전, 대기, 선가압, 비행 등의 전 과정을 통하여 탱크에 충전된 액체산소의 온도상승을 예측할 수 있는 모델을 제시 하였다.

운전조건에 따른 PEMFC 스택의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of PEMFC Stack Depending on Operating Conditions)

  • 이지홍;이명용;이상석;남일상;이도형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.770-777
    • /
    • 2009
  • The energy depletion and the environmental pollution like global warming are worldwide issues. For correcting these problems there are many studies on new-renewable energy in Korea. A kind of new-renewable energy, PEMFC(Proton Exchange Membrane Fuel Cell) is a low temperature fuell cell and there are some cases of small craft or submarine adopted PEMFC system in maritime. PEMFC's performance is affected the operating conditions. Finding optimum operating conditions must be performed before adopting PEMFC to system. So in this study, we experiment about various operating conditions to apply 150W PEMFC stack for a model boat. And through the results, we find optimum operating conditions and study an effect of operating conditions to PEMFC.

전극 및 메트릭스가 인산형 연료전지의 성능에 미치는 영향 (Effects of Electrode and Matrix in the PAFC Performance)

  • 김동진;송락현;이병록;김창수;신동열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1873-1875
    • /
    • 1999
  • The effects of electrode and matrix in the PAFC were investigated using AC-impedance spectroscopy. The performance of PAFC was determined by changing external electronic load. AC impedance measurement was carried out as functions of phosphoric acid impregnation temperature. operating temperature and matrix coating method using various cathodes ; 20%Pt/C, 20%Pt-Ni/C, 20%Pt-Co-Ni/C, 10%Pt-Fe-Co/C, and 20%Pt-Fe-Co/C From the analysis of measured impedance data, the interfacial resistance decreased with increasing operating temperature. and with decreasing impregnation temperature. As compared with the alloy catalysts, Pt catalyst showed a lower interfacial resistance. This consist with the cell performance.

  • PDF

가변열전도성능 히트파이프(VCHP)의 온도제어 성능에 관한 실험 (An Experimental Study on the Temperature-Control Performance of a Variable Conductance Heat Pipe)

  • 부준홍;박철민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2124-2129
    • /
    • 2007
  • A VCHP was fabricated and tested for its thermal performance. The container was made of copper, and the working fluid was water. STS-316 screen of mesh number 100 was inserted as a capillary structure. As a baseline performance, a normal heat pipe of the same dimensions was tested in advance to compare with VCHP, where an inert gas container was attached. The outer diameter of the heat pipe was 12.8 mm and the total length was 600 mm. The evaporator and the condenser lengths were both 200 mm. The thermal load ranged from 20 to 300W. Typical result revealed that the operating temperature of the VCHP stayed almost constant, while that of the normal heat pipe varied as much as 40$^{\circ}C$. Therefore, it was demonstrated that the VCHP is very effective for temperature control of heat-dissipating devices.

  • PDF

스택온도 및 유량변화에 따른 PEMFC의 출력특성 연구 (A Study on Performance of PEMFC with Variations on Stack Temperature and Mass Flow Rate)

  • 박세준;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.140-140
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are $20{\sim}70^{\circ}C$ on stack temperature and 1~8L/min on $H_2$ volume.

  • PDF

A Study On the Design Of Fuzzy Controller for the Steam Temperature Process in the Coal Fired Power Plant

  • Shin, Sang-Doo;Kim, Yi-Gon;Lee, Bong-Kuk
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.350-353
    • /
    • 2003
  • In this paper, we proposed the method to design fuzzy controller using the experience of the operating expert and experimental numeric data for the robust control about the noise and disturbance instead of the traditional PID controller for the main steam temperature control of the thermal power plant. The temperature of main steam temperature process has to be controlled uniformly for the stable electric power output. The process has the problem of the hunting for the cases of various disturbances. In that case, the manual action of the operator happened to be introduced in some cases. We adopted the TSK (Takagi-Sugeno-Kang) model as the fuzzy controller and designed the fuzzy rules using the informations extracted directly from the real plant and various operating condition to solve the above problems and to apply practically. We implemented the real fuzzy controller as the Function Block module in the DCS(Distributed Control System) and evaluated the feasibility through the experiment81 results of the simulation.

  • PDF

친환경 프레온 냉매를 이용하는 단압축 단팽창 냉동시스템의 성능예측 (Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants)

  • 노건상;김종열
    • 수산해양교육연구
    • /
    • 제25권2호
    • /
    • pp.301-306
    • /
    • 2013
  • In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative freon refrigerant for freon refrigerant R22 were used as working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ratio of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants have an effect on COP of this system.

고온형 고분자 전해질 연료전지 스택 내부의 냉각판 수가 스택에 미치는 열 영향성의 수치적 연구 (Analysis of Thermal Effect by Coolant Plate Number in High-Temperature Polymer Electrolyte Membrane Fuel Cell Stack)

  • 최병욱;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.127-135
    • /
    • 2015
  • High-Temperautre Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) with phosphoric acid-doped polybenzimidazole (PBI) membrane has high power density because of high operating temperature from 100 to $200^{\circ}C$. In fuel cell stack, heat is generated by electrochemical reaction and high operating temperature makes a lot of heat. This heat is caouse of durability and performance decrease about stack. For these reasons, heat management is important in HT-PEMFC. So, we developed HT-PEMFC model and study heat flow in HT-PEMFC stack. In this study, we placed coolant plate number per cell number ratio as variable and analysed heat flow distribution in stack.