• Title/Summary/Keyword: operating temperature

Search Result 3,677, Processing Time 0.032 seconds

Modeling for a Coke Dry Quenching Process Using a Theory of a Porous Material (다공질 물질의 냉각현상 연구를 통한 코크스냉각공정의 모델링)

  • Kim, Joo-Han;Lee, Yong-Ju;Kim, Ki-Seok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.697-701
    • /
    • 2012
  • Numerical modeling for a coke dry quenching process was developed and evaluated. The cokes had similar characteristics to a porous material, therefore, its quenching analysis was simplified as a cooling process of porous blocks. A uniform inlet temperature and constant properties of materials in the oven were also assumed. With given operating conditions, temperature profiles in the cokes were calculated and compared to the actual values. The calculated temperature gradient was high at the upper part of the coke flow and the cooling rate decreased as cokes came down to the exit port. The exit port temperature of cokes was similar to the measured value, however, temperature-dependent material properties and operating conditions must be considered to predict the temperature precisely. The calculated results could be applied to design a coke oven to produce high quality cokes.

Study on the Operating Characteristics with Load Condition in Hybrid Solar Heating System during Spring Season (봄철 태양열 하이브리드 시스템의 부하조건 변화에 따른 운전특성 연구)

  • Pyo, Jong-Hyun;Kim, Won-Seok;Cho, Hong-Hyun;Ryu, Nam-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1418-1423
    • /
    • 2009
  • This study describes experimental study on the performance characteristics with load condition in hybrid solar heating system during spring season. The room temperatures, the hot water conditions and the lower part temperatures of heat storage tank were changed to analyze the system performances. As a results, the hot water was significantly affected by the ambient temperature. The indoor setting temperature affected the solar fraction. When the low part temperature of the storage tank increased, the temperature of the hot water rose and the temperature of the hot water in morning was affected by the ambient temperature.

  • PDF

Effects of phosphorus content and operating temperature on the electrochemical performance of phosphorus-doped soft carbons

  • Kim, Eun Hee;Jung, Yongju
    • Carbon letters
    • /
    • v.15 no.4
    • /
    • pp.277-281
    • /
    • 2014
  • A series of high capacity soft carbons with different phosphorus contents were successfully prepared by carbonizing petroleum cokes treated with hypophosphorous acid at $900^{\circ}C$. The effect of phosphorus content on the electrochemical performance of the soft carbons was extensively investigated. The P-doped soft carbons exhibited greatly enhanced discharge capacities and outstanding rate capabilities with increasing phosphorus content. In addition, the influence of temperature on the electrochemical behaviors of the soft carbons was investigated in a wide temperature range of $25^{\circ}C$ to $50^{\circ}C$. Surprisingly, the electrochemical properties of the pristine and P-doped soft carbons were highly sensitive to the operating temperature, unlike conventional graphite. The pristine and P-doped soft carbons exhibited significantly high discharge capacities of 470 and 522 mAh/g, respectively, at a high temperature of $50^{\circ}C$.

A Low Voltage Bandgap Current Reference with Low Dependence on Process, Power Supply, and Temperature

  • Cheon, Jimin
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.8 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • The minimum power supply voltage of a typical bandgap current reference (BGCR) is limited by operating temperature and input common mode range (ICMR) of a feedback amplifier. A new BGCR using a bandgap voltage generator (BGVG) is proposed to minimize the effect of temperature, supply voltage, and process variation. The BGVG is designed with proportional to absolute temperature (PTAT) characteristic, and a feedback amplifier is designed with weak-inversion transistors for low voltage operation. It is verified with a $0.18-{\mu}m$ CMOS process with five corners for MOS transistors and three corners for BJTs. The proposed circuit is superior to other reported current references under temperature variation from $-40^{\circ}C$ to $120^{\circ}C$ and power supply variation from 1.2 V to 1.8 V. The total power consumption is $126{\mu}W$ under the conditions that the power supply voltage is 1.2 V, the output current is $10{\mu}A$, and the operating temperature is $20^{\circ}C$.

Effects of Operating Temperature and Electrode Gap Distance on Electricity Generation in Microbial Fuel Cells (미생물연료전지의 전기생산에 미치는 운전온도 및 전극간 거리의 영향)

  • Choi, Young-Dae;Lee, Myoung-Eun;Song, Young-Chae;Woo, Jung-Hui;Yoo, Kyu-Seon;Lee, Chae-Young;Chung, Jae-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • The effects of operating temperature and electrode gap distance on electricity generation were investigated in two-chamber type MFCs. Voltages across the external resistor $(100\;{\Omega})$ were enhanced approximately 1.4 times by the increase of operating temperature from $30^{\circ}C$ to $34^{\circ}C$. The open circuit voltages (OCVs) were increased by the increase of temperature and the maximum power of MFC was obtained at higher current condition by increasing temperature and reducing electrode gap distance. The maximum power densities were enhanced from 1.9 to 2.4 times according to the experimented electrode gap distances by increasing temperature of $4^{\circ}C$. The electricity generation was increased with the decrease of electrode gap distance. The effects of operating temperature and electrode gap distance were closely connected with the internal resistance of MFC system. That is, the increase of temperature and decrease of electrode gap distance reduced the internal resistance of MFC, resulting in the enhancement of electricity generation of MFC.

Operating Characteristics Study of a Small Gas/Steam Turbine Combined System Using Biogas (바이오가스 연료를 사용하는 소형 가스/증기터빈 복합 발전 시스템의 성능특성 해석)

  • Kang, Do-Won;Shin, Hyun-Dong;Kim, Tong-Seop;Hur, Kwang-Beom;Park, Jung-Keuk
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2012
  • This study analyzed the influence of firing biogas on the performance and operation of a gas/steam turbine combined system. A reference gas/steam turbine combined system, designed with biogas fuel(57% volumetric methane) was set up and off-design simulation was made to investigate operating characteristics when a couple of operating schemes to mitigate turbine blade overheating were applied. Performance at base-load operation using each scheme was compared and part load operation using the variable inlet guide vane was analysed. Also, differences in operating characteristics and performance caused by changes in the methane content of biogas and ambient temperature were examined.

Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions (가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석)

  • 박홍희;박윤철;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF

Performance Characterization of Polymer Electrolyte Membrane Direct Methanol Fuel Cell on the Various Operation Conditions (운전조건에 따른 고분자 직접메탄올 연료전지 성능 특성)

  • Jung, Doo-Hwan;Lee, Chang-Hyeong;Shin, Dong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1409-1411
    • /
    • 1996
  • Direct Methanol Fuel Cell(DMFC) using Pt-Ru electrocatlayst and Nafion menbrane can provide high performance if operating conditions are well designed. In this study, operating temperature, pressure, and fuel flow rate were changed to obtain optimum operating conditions of DHFC single cell. Performance of DMFC were increased by the increase of operating temperature. The concentration of fuel methanol was 2.0M $CH_{3}OH$ and pressure difference of cathode and anode was 2 atm were showed maximum performance of DMFC single cell with showing the current density of 160 $mA/cm^2$ at 0.2V cell voltage.

  • PDF

Study for Synthetic Oil Performance Test Comparing with Mineral Gear oil in an Agitator Gear Box:Power consumption, Temperature, Oil & parts life for the Heavy load gear box in the Phosphoric Acid Plant (뉴스초점 - 광유와 합성유의 에너지 소비량, 온도변화 등의 성능시험 비교 고찰)

  • Lee, Jae Keun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.45 no.6
    • /
    • pp.28-32
    • /
    • 2012
  • Namhae chemical is one of the largest fertilizer manufacturing company in Korea which company has operating 4 unit agitator gear boxes and producing variety kinds of fertilizer production. The gearbox operating temperature of agitator is approximated in $55^{\circ}C{\sim}90^{\circ}C$ and required to keep operating continuous without stopping. The system required high performance oil and longer oil drain interval as limited workforce in maintenance team. It was lubricated by mineral gear oil of ISO VG 320 and also need to change to new oil frequently. Namhae Chemical would expect to keep stable operating condition without shut down and consider, lower cost of operation and equipment protection.

  • PDF

A Study on Effects of Operating Temperatures of Cyclone on Pressure Drop (사이클론의 작동온도가 압력손실에 미치는 영향에 관한 연구)

  • Kwak, Ji-Young;Song, Myung-Jun;Lee, Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.515-519
    • /
    • 2012
  • A numerical study was performed to observe the relation between internal flow characteristics and operating temperatures in a Lapple cyclone. The present numerical results agree reasonably well with previous experimental and numerical results. As the operating temperature increases, the pressure drop decreases due to decrease of wall shear stress and tangential velocities. A detailed comparison of pressure drops in the cyclone between theoretical prediction models and the present numerical simulations is also presented for wide range of operating temperatures.

  • PDF