• 제목/요약/키워드: operating frequency

검색결과 2,848건 처리시간 0.031초

직류 전원 분할용 커패시터의 용량 변화에 따른 ZVS-HB형 고주파 공진 인버터의 특성해석 (Characteristics Analysis of ZVS-HB Type High Frequency Resonant Inverter According to the Variable Capacitance of the DC Voltage Source Separation Capacitor)

  • 문창수;김종해;김동희;오승훈;심광열;민병재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.352-357
    • /
    • 2000
  • This paper presents about an example of circuit design and characteristics of inverter according to the variable capacitance of the DC voltage source separation capacitor used in ZVS-HB type high frequency resonant inverter. The soft switching technology known as ZVS is used to reduce turn off loss at switching. In the event the capacitance of the DC voltage source separation capacitor is varied, the analysis of inverter circuit has generally described by using normalized parameter and operating characteristics have been evaluated in terms of switching frequency and parameters. According to the calculated characteristics value, a method of the circuit designs and operating characteristic of the inverter is also presented in this paper. In addition, this paper proves the validity of theoretical analysis through the experiment. This proposed inverter shows that it can be practically used in future as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF

배터리 가용성 극대화를 고려한 BESS의 AGC 주파수제어 추종운영방안 (Operating Method of BESS for Providing AGC Frequency Control Service Considering Its Availability Maximization)

  • 최우영;유가람;국경수
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1161-1168
    • /
    • 2016
  • Battery energy storage system(BESS) attract the attention of the power system operators with its fast response to a disturbance in spite of its limited energy capacity. This paper proposes the operating method of BESS for following the Automatic Generation Control(AGC) frequency control which is centrally distributed by a system operator. As BESS needs to just meet the control requirement from the system operator, it should be able to properly manage the state of charge(SOC) of BESS to be available to control signal. For doing these, the proposed method distributes the control requirement to available batteries in proportion to its SOC. In addition, unavailable batteries are controlled to recover the SOC to an appropriate range, and the recovering power is supplied by available batteries meeting the control requirement. Moreover, the proposed method manages the efficiency of power conversion system (PCS) by limiting the number of PCS to be assigned for the low control requirement. Finally, the case studies are carried out to verify the effectiveness of proposed strategy.

Investigation of ITU Radio Regulations Regarding KPS Service Band

  • Subin Lee;Kahee Han;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권2호
    • /
    • pp.177-184
    • /
    • 2023
  • In order to reserve frequency bands for stable operation of the Korean Positioning System (KPS), it must be demonstrated that the impact of interference caused by KPS on other services operating in the same bands is tolerable. The International Telecommunication Union (ITU) provides the radio regulations and a compatibility assessment methodology for the coexistence of different services in limited frequency resources. The purpose of this paper is to investigate the radio regulations regarding the compatibility issues between the KPS and other services sharing the same frequency bands. The results of the investigation show that the RNSS system can be operated in the L5-band under the condition that the Power Flux Density (PFD) and Aggregated Equivalent PFD (AEPFD) thresholds specified in the radio regulations are met. In addition, the ITU recommends that the interference-to-noise ratio (INR) protection criteria be met to prevent degradation of the performance of radar systems operating in the L2/L6-band. In the case of the S-band, coordination of allocations for RDSS space stations with respect to terrestrial services is not required if the PFD does not exceed regulated thresholds regulated by ITU.

비예혼합 제트화염에서 고주파수의 노즐 구멍음에 의한 부상화염 혼합성능에 관한 연구 (A Study on the Mixing Capacity of Lifted Flame by the Nozzle Hole-tone of High Frequency in Non-premixed Jet Flames)

  • 조준익;이기만
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.35-40
    • /
    • 2011
  • An experimental investigation of the characteristic of non-premixed lifted flames with nozzle hole-tone of high-frequency has been performed. Before the fuel was supplied to nozzle, the fuel was supplied through a burner cavity which was located under the nozzle. The fuel passed through the excitation cavity under the influence of the high-frequency affects the lifted flame characteristics. The measurements were performed in flow range that occurs lifted flame and blow out. When the high-frequency is generated from burner cavity, the lifted length became shorter, and noise reduced comparing to unexcitation case. Additionally, operating flow range was increased and diameter of flame base became smaller with high-frequency effect. Through this experiments, it's ascertained that the high-frequency excitation can be adopted with effective method for flame stability and noise reduction.

A G-Band Frequency Doubler Using a Commercial 150 nm GaAs pHEMT Technology

  • Lee, Iljin;Kim, Junghyun;Jeon, Sanggeun
    • Journal of electromagnetic engineering and science
    • /
    • 제17권3호
    • /
    • pp.147-152
    • /
    • 2017
  • This paper presents a frequency doubler operating at G-band that exceeds the maximum oscillation frequency ($f_{max}$) of the given transistor technology. A common-source transistor is biased on class-B to obtain sufficient output power at the second harmonic frequency. The input and output impedances are matched to achieve high output power and high return loss. The frequency doubler is fabricated in a commercial 150-nm GaAs pHEMT process and obtains a measured conversion gain of -5.5 dB and a saturated output power of -7.5 dBm at 184 GHz.

2종의 Ferrite가 혼합된 복합 Ferrite 전파흡수체의 정합주파수 제어 (Control of Matching Frequency of Ferrite Composite Microwave Absorber Consisted of Two Kinds of Ferrites)

  • 권형주;신재영;오재희
    • 한국세라믹학회지
    • /
    • 제30권10호
    • /
    • pp.823-828
    • /
    • 1993
  • The performance of ferrite composite microwave absorber has been evaluated as the matching frequency, the matching thickness and the band width. Especially, matching frequency is very important in application of microwave absorber because it determines operating frequency range. In this study, the ferrite composite microwave absorbers consisted Ni-Zn ferrite and Zn2Y ferroxplana were prepared in order to control matching frequency. Then, the variation of the material constants and microwave absorbing characteristics were investigated with various ferrite mixing ratio. The material constants of ferrite composite microwave absorber could be controlled by variation ferrite mixing ratio. Therefore, it was confirm that matching frequency of microwave absorber could be shifted by control of material constants.

  • PDF

PDM ZCS Resonant High Frequency Inverter for Induction Heated Roller

  • Kang, Shin-Chul
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presents a lossless inductor snubber-assisted series resonant high frequency inverter using the trench gate IGBTs for the electromagnetic induction eddy current-heated fixing roller in copy and printing machines in a new generation. This soft switching high-frequency inverter can completely achieve zero current soft switching (ZCS) commutation mode transitions and wide power regulation under its constant frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally presented for a constant frequency PDM strategy under a ZCS operation, together with its output power regulation characteristics-based on the pulse density modulation. The effectiveness of this soft switching high-frequency inverter is confirmed for the fixing equipment with the induction-heated fixing roller.

전력설비의 정밀주파수진단을 위한 기법 (A Technique for Accurate Measurement of Power System Frequency)

  • 남시복;이훈구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.66-70
    • /
    • 2006
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, il requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

디지털 이동통신단말기용 IF 주파수합성기 IC개발에 관한 연구 (The Study of If Frequency Synthesizer IC Design for Digital Cellular Phone)

  • 이규복;정덕진
    • 마이크로전자및패키징학회지
    • /
    • 제8권1호
    • /
    • pp.19-25
    • /
    • 2001
  • 본 연구에서는 디지털 셀룰러용 IF Frequency Synthesizer의 설계, 시뮬레이션 결과 및 측정 결과를 기술하였으며, 공정 및 소자 라이브러리는 AMS사의 0.8 $\mu\textrm{m}$ BiCMOS를 사용하였다. IF Frequency Synthesizer부는 IF 전압제어발진기, 위상검파기, 8분배기, 차지 펌프 및 루프 필터(Loop Filter) 등을 포함하고 있다. 공급전원은 2.7에서 3.6 V이며, IF VCO의 조절전압은 0.5~2.7V이고, 소비전류는 11 mA로 설계결과와 측정결과가 유사한 결과를 보였다.

  • PDF

전력계통 주파수의 고속.정밀측정을 위한 기법 (A Technique for Fast and Accurate Measurement of Power System Frequency)

  • 남시복;이훈구;마석범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.68-71
    • /
    • 2004
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF