• 제목/요약/키워드: operating frequency

검색결과 2,848건 처리시간 0.035초

A Novel Power Frequency Changer Based on Utility AC Connected Half-Bridge One Stage High Frequency AC Conversion Principle

  • Saha Bishwajit;Koh Kang-Hoon;Kwon Soon-Kurl;Lee Hyun-Woo;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.203-205
    • /
    • 2006
  • This paper presents a novel soft-switching PWM utility frequency AC to high frequency AC power conversion circuit incorporating boost-half-bridge inverter topology, which is more suitable and acceptable for cost effective consumer induction heating applications. The operating principle and the operation modes are presented using the switching mode and the operating voltage and current waveforms. The performances of this high-frequency inverter using the latest IGBTs are illustrated, which includes high frequency power regulation and actual efficiency characteristics based on zero voltage soft switching (ZVS) operation ranges and the power dissipation as compared with those of the previously developed high-frequency inverter. In addition, a dual mode control scheme of this high frequency inverter based on asymmetrical pulse width modulation (PWM) and pulse density modulation (PDM) control scheme is discussed in this paper in order to extend the soft switching operation ranges and to improve the power conversion efficiency at the low power settings. The power converter practical effectiveness is substantially proved based on experimental results from practical design example.

  • PDF

스마트 기기용 강화유리&사파이어 유리 전용 가공기의 진동해석을 통한 설계 개선에 관한 연구 (A Study on Design Improvement by Vibration Analysis of Hardened Glass & Sapphire Machining Equipment for Smart IT Parts Industry)

  • 조준현;박상현;안범상;이종찬
    • 한국기계가공학회지
    • /
    • 제15권2호
    • /
    • pp.51-56
    • /
    • 2016
  • High brittleness is a characteristic of glass, and in many cases it is broken during the process of machining due to processing problems, such as scratches, chipping, and notches. Machining defects occur due to the vibration of the equipment. Therefore, design techniques are needed that can control the vibration generated in the equipment to increase the strength of tempered glass. The natural frequency of the machine tool via vibration analysis (computer simulation) must be accurately understood to improve the design to ensure the stability of the machine. To accurately understand the natural frequency, 3D modeling, which is the same as actual apparatus, was used and a constraint condition was also applied that was the same as that of the actual apparatus. The maximum speeds of ultrasonic and high frequency, which are 15,000 rpm and 60,000 rpm, respectively, are considerably faster than those of typical machine tools. Therefore, an improved design is needed so that the natural frequency is formed at a lower region and the natural frequency does not increase through general design reinforcement. By restructuring the top frame of the glass processing, the natural frequency was not formed in the operating speed area with the improved design. The lower-order natural frequency is dominant for the effects that the natural frequency has on the vibration. Therefore, the design improvement in which the lower-order natural frequency is not formed in the operating speed area is an optimum design improvement. It is possible to effectively control the vibrations by avoiding resonance with simple design improvements.

A Novel Utility AC Frequency to High Frequency AC Power Converter with Boosted Half-Bridge Single Stage Circuit Arrangement

  • Saha, Bishwajit;Kwon, Soon-Kurl;Koh, Hee-Seog;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2006
  • This paper presents a novel soft-switching PWM utility frequency AC to high frequency AC power conversion circuit Incorporating boost-half-bridge inverter topology, which is more suitable and acceptable for cost effective consumer induction heating applications. The operating principle and the operation modes are presented using the switching mode and the operating voltage and current waveforms. The performances of this high-frequency inverter using the latest IGBTs are illustrated, which includes high frequency power regulation and actual efficiency characteristics based on zero voltage soft switching (ZVS) operation ranges and the power dissipation as compared with those of the previously developed high-frequency inverter. In addition, a dual mode control scheme of this high frequency inverter based on asymmetrical pulse width modulation (PWM) and pulse density modulation (PDM) control scheme is discussed in this paper in order to extend the soft switching operation ranges and to improve the power conversion efficiency at the low power settings. The power converter practical effectiveness is substantially proved based on experimental results from practical design example.

  • PDF

M/W 중계기용 아날로그 Predistorter의 설계 및 구현 (Design and Implementation of an Analog Predistorter for M/W Repeaters)

  • 강상기;유준규;장대익
    • 한국정보통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.33-38
    • /
    • 2008
  • M/W 주파수 변환 중계기는 송신 궤환 신호에 의한 발진 가능성이 적고, 가시거리 통신을 하기 때문에 타 시스템에 대한 간섭도 적다. 때문에 도서 지역 등에 기지국 신호를 전송하는 경우에 M/W 중계기를 많이 이용한다. 본 논문에는 이동통신 M/W 주파수 변환 송신기에 적용 가능한 아날로그 predistorter의 설계와 구현에 관한 내용이 기술되어 있다. 본 논문에서 이용한 M/W 주파수 변환 송신기는 1010+/10 MHz의 신호를 11GHz 대역으로 주파수 변환해서 전송한다. 11GHz 대역에서 predistorter를 구현하기는 매우 어렵기 때문에 논문에서는 IF 대역인 1010MHz 대역에서 동작하는 predistorter를 구현하였다. 이와 같은 IF 대역에서 동작하는 predistorter는 IF 단 이후의 전체 송신기를 선형화 하는 효과가 있다. Predistorter의 성능 실험 결과 M/W 주파수 변환 송신기가 10.805GHz에서 25dBm을 출력 할 때 10dB의 ACPR(Adjacent Channel Power Ratio)이 개선됨을 확인하였다.

계통 주파수 추정을 위한 디지털 알고리즘 간의 비교 (A comparison between digital algorithms for estimation of power system frequency)

  • 이병현;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.276-277
    • /
    • 2006
  • Estimation of power system frequency is an important task because frequency deviation is a good indicator of the system abnormal operating conditions. The algorithms, curve fitting, technique using Taylor series, deviation of phasor angle of fundamental waveform using DFT (Discrete Fourier Transform) and Prony method, are tested under operation of the frequency relaying by using EMTP MODELS. The performance of methods is compared with the simulation results.

  • PDF

산술 연산 구조의 VCO를 이용한 3.3V 고주파수 CMOS 주파수 합성기의 설계 (Design of a 3.3V high frequency CMOS PLL with an arithmetic functionality VCO)

  • 한윤철;윤광섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.81-84
    • /
    • 2001
  • In recent years, the design of CMOS VCO at ever-higher frequencies has gained interest. This paper proposes an arithmetic functionality VCO circuit based on a differential ring oscillator for operating in high frequency. The proposed VCO architecture with half adder is able to produce two times higher frequency with my delay cell than conventional VCO produce double oscillation frequency and power dissipation is 14.59mW.

  • PDF

견인전동기의 정격운전점 선정에 따른 전동기의 무게와 견인력 비교 (Comparison of weight and tractive effort of traction motor by choosing different rated operating point)

  • 박창순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.361-363
    • /
    • 1997
  • Rated frequency of inverter driven induction motor for a traction system can be chosen lower or higher. Traction motor with higher rated frequency can be lighter than the lower. But the maximum torque must be checked, because it is very important for starting and acceleration and it should be reduced with high frequency operation. In the paper, two motors with different rated frequency are designed and compared.

  • PDF

A New Method to Estimate the Magnetic Field Modulation Effect of Brushless Doubly-Fed Machine with Cage Rotor

  • Liu, Hanghang;Han, Li;Gao, Qiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.330-335
    • /
    • 2012
  • Brushless doubly-fed machine (BDFM) doesn't use brush and slip ring, and has advantages such as high system reliability, small capacity of its frequency converter, low system cost, adjustable power factor and speed, etc. At the same time, it has good applicable potentials on the variable frequency motors and the variable speed constant frequency generators. However, due to the complicacy and particularity of BDFM in the structure and operating mechanism, the effect of magnetic field modulation directly influences the operating efficiency of BDFM. To study the effect of different cage rotor structures on the magnetic field modulation of BDFM, the rotor magnetomotive force (MMF) of BDFM with cage rotor is studied by the analytical method. The components and features of rotor harmonic MMFs are discussed. At the same time, the method to weaken the higher harmonics is analyzed by the theoretic formulae. Furthermore, the magnetic field modulation mechanism is expounded on in detail and the relationship between the magnetic field modulation effect and the operating efficiency of BDFM is established. And then, a new method for estimating the magnetic field modulation effect is proposed. At last, the magnetic field modulation effects of four BDFM prototypes with different cage rotor structures are compared by the MMF analysis and the efficiency data of electromagnetic design. The results verify the effectiveness of the new method for estimating the magnetic field modulation effect of BDFM with cage rotor.

전력계통 적용을 위한 배터리 에너지저장장치의 동적 제어모드 판단기준에 관한 연구 (A Study on the Criteria for Setting the Dynamic Control Mode of Battery Energy Storage System in Power Systems)

  • 한준범;유가람;국경수;장병훈
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.444-450
    • /
    • 2013
  • This paper presents the criteria for setting the dynamic operating mode of BESS(Battery Energy Storage System) in the bulk power systems. ESS has been expected to improve the degraded dynamic performance of the power system with high penetration of the renewable resources. While ESS is controlled in steady state or dynamic operating mode for its better effectiveness depending on the operating conditions of power systems, the criteria for setting the dynamic operating mode for the transient period needs to be robust enough to cover all the different conditions. The proposed criteria consider the varying conditions and the operating practices of the bulk power systems.

유압 제어계에서 서보밸브 모델링을 위한 새로운 선형화 방정식의 제안 (A New Linearized Equation for Modelling a Servovalve in Hydraulic Control Systems)

  • 김태형;이일영
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.789-797
    • /
    • 2003
  • In the procedure of the hydraulic control system design, a linearized approximate equation described by the first order terms of Taylor series has been widely used. Such a linearized equation is effective just near the operating point, However, pressure and flowrate in actual hydraulic systems are usually not confined near an operating point. This study suggests a new linearized flow equation for a servovalve as a modified form of the conventional linearized flow equation. Subsequently, a procedure to determine effective operating point for the new linearized equation is proposed. From the evaluations of time responses and frequency responses obtained from simulations for a hydraulic control system, the effectiveness of the new linearized equation and the procedure to determine effective operating point is confirmed.