• 제목/요약/키워드: operating characteristic

검색결과 1,766건 처리시간 0.034초

Risk-Scoring System for Prediction of Non-Curative Endoscopic Submucosal Dissection Requiring Additional Gastrectomy in Patients with Early Gastric Cancer

  • Kim, Tae-Se;Min, Byung-Hoon;Kim, Kyoung-Mee;Yoo, Heejin;Kim, Kyunga;Min, Yang Won;Lee, Hyuk;Rhee, Poong-Lyul;Kim, Jae J.;Lee, Jun Haeng
    • Journal of Gastric Cancer
    • /
    • 제21권4호
    • /
    • pp.368-378
    • /
    • 2021
  • Purpose: When patients with early gastric cancer (EGC) undergo non-curative endoscopic submucosal dissection requiring gastrectomy (NC-ESD-RG), additional medical resources and expenses are required for surgery. To reduce this burden, predictive model for NC-ESD-RG is required. Materials and Methods: Data from 2,997 patients undergoing ESD for 3,127 forceps biopsy-proven differentiated-type EGCs (2,345 and 782 in training and validation sets, respectively) were reviewed. Using the training set, the logistic stepwise regression analysis determined the independent predictors of NC-ESD-RG (NC-ESD other than cases with lateral resection margin involvement or piecemeal resection as the only non-curative factor). Using these predictors, a risk-scoring system for predicting NC-ESD-RG was developed. Performance of the predictive model was examined internally with the validation set. Results: Rate of NC-ESD-RG was 17.3%. Independent pre-ESD predictors for NC-ESD-RG included moderately differentiated or papillary EGC, large tumor size, proximal tumor location, lesion at greater curvature, elevated or depressed morphology, and presence of ulcers. A risk-score was assigned to each predictor of NC-ESD-RG. The area under the receiver operating characteristic curve for predicting NC-ESD-RG was 0.672 in both training and validation sets. A risk-score of 5 points was the optimal cut-off value for predicting NC-ESD-RG, and the overall accuracy was 72.7%. As the total risk score increased, the predicted risk for NC-ESD-RG increased from 3.8% to 72.6%. Conclusions: We developed and validated a risk-scoring system for predicting NC-ESD-RG based on pre-ESD variables. Our risk-scoring system can facilitate informed consent and decision-making for preoperative treatment selection between ESD and surgery in patients with EGC.

Accuracy of one-step automated orthodontic diagnosis model using a convolutional neural network and lateral cephalogram images with different qualities obtained from nationwide multi-hospitals

  • Yim, Sunjin;Kim, Sungchul;Kim, Inhwan;Park, Jae-Woo;Cho, Jin-Hyoung;Hong, Mihee;Kang, Kyung-Hwa;Kim, Minji;Kim, Su-Jung;Kim, Yoon-Ji;Kim, Young Ho;Lim, Sung-Hoon;Sung, Sang Jin;Kim, Namkug;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제52권1호
    • /
    • pp.3-19
    • /
    • 2022
  • Objective: The purpose of this study was to investigate the accuracy of one-step automated orthodontic diagnosis of skeletodental discrepancies using a convolutional neural network (CNN) and lateral cephalogram images with different qualities from nationwide multi-hospitals. Methods: Among 2,174 lateral cephalograms, 1,993 cephalograms from two hospitals were used for training and internal test sets and 181 cephalograms from eight other hospitals were used for an external test set. They were divided into three classification groups according to anteroposterior skeletal discrepancies (Class I, II, and III), vertical skeletal discrepancies (normodivergent, hypodivergent, and hyperdivergent patterns), and vertical dental discrepancies (normal overbite, deep bite, and open bite) as a gold standard. Pre-trained DenseNet-169 was used as a CNN classifier model. Diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis, t-stochastic neighbor embedding (t-SNE), and gradient-weighted class activation mapping (Grad-CAM). Results: In the ROC analysis, the mean area under the curve and the mean accuracy of all classifications were high with both internal and external test sets (all, > 0.89 and > 0.80). In the t-SNE analysis, our model succeeded in creating good separation between three classification groups. Grad-CAM figures showed differences in the location and size of the focus areas between three classification groups in each diagnosis. Conclusions: Since the accuracy of our model was validated with both internal and external test sets, it shows the possible usefulness of a one-step automated orthodontic diagnosis tool using a CNN model. However, it still needs technical improvement in terms of classifying vertical dental discrepancies.

Does dexmedetomidine combined with levobupivacaine in inferior alveolar nerve blocks among patients undergoing impacted third molar surgery control postoperative morbidity?

  • Patil, Shweta Murlidhar;Jadhav, Anendd;Bhola, Nitin;Hingnikar, Pawan;Kshirsagar, Krutarth;Patil, Dipali
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.145-153
    • /
    • 2022
  • Background: Postoperative analgesia (POA) is an important determinant of successful treatment. Dexmedetomidine (DEX) has recently gained attention as a promising adjuvant to local anesthetics (LA). The present study aimed to evaluate the efficacy and safety of levobupivacaine (LB) as an adjuvant during inferior alveolar nerve block (IANB) in the extraction of lower impacted third molars (LITM). Methods: A prospective, randomized, placebo-controlled, triple-blind, parallel-arm, and clinical study was performed on 50 systemically healthy participants who required removal of an asymptomatic LITM. Using a 1:1 distribution, the participants were randomized into two groups (n = 25). Group L (control group) received 1.8 mL of 0.5% LB and 0.2 mL normal saline (placebo) and Group D (study group) received a blend of 1.8 mL of 0.5% LB and 0.2 mL (20 ㎍) DEX. The primary outcome variable was the duration of POA and hemodynamic stability, and the secondary variable was the total number of analgesics required postoperatively for up to 72 h. The participants were requested to record the time of rescue analgesic use and the total number of rescue analgesics taken. The area under the curve was plotted for the total number of analgesics administered. The pain was evaluated using the visual analog scale. Data analysis was performed using paired students and unpaired t-test, Mann-Whitney U test, Chi-square test, and receiver operating characteristic analysis. Statistical significance was set at P < 0.05. Results: The latency, profoundness of anesthesia, and duration of POA were statistically significant (P < 0.05). The differences between mean pain scores at 6, 12, 24, 48, and 72 h were found to be significant (each P = 0.0001). Fewer analgesics were required by participants in group D (2.12 ± 0.33) than in L (4.04 ± 0.67), with a significant difference (P = 0.0001). Conclusion: Perineurally administered LA with DEX is a safe, effective, and therapeutic approach for improving latency, providing profound POA, and reducing the need for postoperative analgesia.

The Effect of Hounsfield Unit Value with Conventional Computed Tomography and Intraoperative Distraction on Postoperative Intervertebral Height Reduction in Patients Following Stand-Alone Anterior Cervical Discectomy and Fusion

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung;Woo, Joon Bum;Kim, Young Ha
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권1호
    • /
    • pp.96-106
    • /
    • 2022
  • Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24-70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.

공정안전성과지표 적용을 위한 공정안전시스템 분석방안 연구 (A Study on Process Safety System Analysis for Application Process Safety Performance Indicators)

  • 고병석;임동휘;김민섭;설지우;유병태;고재욱
    • 한국가스학회지
    • /
    • 제26권2호
    • /
    • pp.27-38
    • /
    • 2022
  • 선진국에서는 공정안전관리제도의 도입으로 사고는 상당히 감소하였으나, 규제적 성격을 띄며, 실질적인 사업장안전관리의 실태를 보여주기 어렵다는 한계를 보인다. 많은 기관에서 공정안전상태를 포괄적으로 모니터링 할 수 있는 공정안전성과지표의 사용을 권장하고 있다. 본 연구에서는 공정안전성과지표 적용을 위하여 관련 Guideline을 비교·분석하고 사업장의 공정안전시스템을 분석하여 지표로 활용하는 방안을 검토하였다. 문헌적 지표에서는 절차의 준수 여부 위주로 확인하는 반면, 시스템 기반의 지표에서는 안전시스템의 특정 목적을 위한 절차나 검사 등을 명확하게 식별할 수 있도록 하고, 운영상태가 어떤지 측정하여 모니터링 할 수 있다. 이러한 특성은 안전관리 활동을 운영함에 있어 도출되는 보완사항들의 명료성 측면에서 더 유리함을 알 수 있다. 이를 활용하여 사업장 안전관리 수준을 효과적으로 보여줄 수 있다.

심층학습 알고리즘을 활용한 인접면 우식 탐지 (Detection of Proximal Caries Lesions with Deep Learning Algorithm)

  • 김현태;송지수;신터전;현홍근;김정욱;장기택;김영재
    • 대한소아치과학회지
    • /
    • 제49권2호
    • /
    • pp.131-139
    • /
    • 2022
  • 이번 연구는 소아의 인접면 우식을 진단하는데 있어 사용하고 있는 구내방사선 사진에서 심층학습(deep learning) 알고리즘을 활용하여 치아우식을 진단하는 모델의 성능을 평가하고자 하였다. 제1유구치와 제2유구치 사이의 인접면이 포함된 500개의 구내방사선 사진을 대상으로 연구를 시행하였다. 치아우식을 진단하는 모델의 학습에는 Resnet50 기반의 인공신경망 모델을 사용하였다. 평가자료군에서 진단모델의 정확도, 민감도, 특이도를 구하고, ROC 곡선을 얻어 AUC 값을 바탕으로 분류 모델의 성능을 평가하였다. 학습 모델의 정확도는 0.84, 민감도는 0.74, 특이도는 0.94로 나타났으며 AUC는 0.86으로 나타났다. 인공신경망을 기반으로 하는 소아의 구내방사선 사진에서의 인접면 우식의 진단 모델은 비교적 높은 정확도를 보여주었다. 심층학습 모델은 구내방사선 사진상에서 인접면 우식을 진단하는데 있어 향후 치과의사를 보조하는 진단 도구로서 활용될 수 있을 것이다.

Percentile-Based Analysis of Non-Gaussian Diffusion Parameters for Improved Glioma Grading

  • Karaman, M. Muge;Zhou, Christopher Y.;Zhang, Jiaxuan;Zhong, Zheng;Wang, Kezhou;Zhu, Wenzhen
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권2호
    • /
    • pp.104-116
    • /
    • 2022
  • The purpose of this study is to systematically determine an optimal percentile cut-off in histogram analysis for calculating the mean parameters obtained from a non-Gaussian continuous-time random-walk (CTRW) diffusion model for differentiating individual glioma grades. This retrospective study included 90 patients with histopathologically proven gliomas (42 grade II, 19 grade III, and 29 grade IV). We performed diffusion-weighted imaging using 17 b-values (0-4000 s/mm2) at 3T, and analyzed the images with the CTRW model to produce an anomalous diffusion coefficient (Dm) along with temporal (𝛼) and spatial (𝛽) diffusion heterogeneity parameters. Given the tumor ROIs, we created a histogram of each parameter; computed the P-values (using a Student's t-test) for the statistical differences in the mean Dm, 𝛼, or 𝛽 for differentiating grade II vs. grade III gliomas and grade III vs. grade IV gliomas at different percentiles (1% to 100%); and selected the highest percentile with P < 0.05 as the optimal percentile. We used the mean parameter values calculated from the optimal percentile cut-offs to do a receiver operating characteristic (ROC) analysis based on individual parameters or their combinations. We compared the results with those obtained by averaging data over the entire region of interest (i.e., 100th percentile). We found the optimal percentiles for Dm, 𝛼, and 𝛽 to be 68%, 75%, and 100% for differentiating grade II vs. III and 58%, 19%, and 100% for differentiating grade III vs. IV gliomas, respectively. The optimal percentile cut-offs outperformed the entire-ROI-based analysis in sensitivity (0.761 vs. 0.690), specificity (0.578 vs. 0.526), accuracy (0.704 vs. 0.639), and AUC (0.671 vs. 0.599) for grade II vs. III differentiations and in sensitivity (0.789 vs. 0.578) and AUC (0.637 vs. 0.620) for grade III vs. IV differentiations, respectively. Percentile-based histogram analysis, coupled with the multi-parametric approach enabled by the CTRW diffusion model using high b-values, can improve glioma grading.

Prediction of 6-Month Mortality Using Pre-Extracorporeal Membrane Oxygenation Lactate in Patients with Acute Coronary Syndrome Undergoing Veno-Arterial-Extracorporeal Membrane Oxygenation

  • Kim, Eunchong;Sodirzhon-Ugli, Nodirbek Yuldashev;Kim, Do Wan;Lee, Kyo Seon;Lim, Yonghwan;Kim, Min-Chul;Cho, Yong Soo;Jung, Yong Hun;Jeung, Kyung Woon;Cho, Hwa Jin;Jeong, In Seok
    • Journal of Chest Surgery
    • /
    • 제55권2호
    • /
    • pp.143-150
    • /
    • 2022
  • Background: The effectiveness of extracorporeal membrane oxygenation (ECMO) for patients with refractory cardiogenic shock or cardiac arrest is being established, and serum lactate is well known as a biomarker of end-organ perfusion. We evaluated the efficacy of pre-ECMO lactate for predicting 6-month survival in patients with acute coronary syndrome (ACS) undergoing ECMO. Methods: We reviewed the medical records of 148 patients who underwent veno-arterial (VA) ECMO for ACS between January 2015 and June 2020. These patients were divided into survivors and non-survivors based on 6-month survival. All clinical data before and during ECMO were compared between the 2 groups. Results: Patients' mean age was 66.0±10.5 years, and 116 (78.4%) were men. The total survival rate was 45.9% (n=68). Cox regression analysis showed that the pre-ECMO lactate level was an independent predictor of 6-month mortality (hazard ratio, 1.210; 95% confidence interval [CI], 1.064-1.376; p=0.004). The area under the receiver operating characteristic curve of pre-ECMO lactate was 0.64 (95% CI, 0.56-0.72; p=0.002; cut-off value=9.8 mmol/L). Kaplan-Meier survival analysis showed that the cumulative survival rate at 6 months was significantly higher among patients with a pre-ECMO lactate level of 9.8 mmol/L or less than among those with a level exceeding 9.8 mmol/L (57.3% vs. 31.8%, p=0.0008). Conclusion: A pre-ECMO lactate of 9.8 mmol/L or less may predict a favorable outcome at 6 months in ACS patients undergoing VA-ECMO. Further research aiming to improve the accuracy of predictions of reversibility in patients with high pre-ECMO lactate levels is essential.

Influence of kilovoltage- peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

  • Fontenele, Rocharles Cavalcante;Nascimento, Eduarda Helena Leandro;Imbelloni-Vasconcelos, Ana Catarina;Martins, Luciano Augusto Cano;Pontual, Andrea dos Anjos;Ramos-Perez, Flavia Maria Moraes;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제52권3호
    • /
    • pp.267-273
    • /
    • 2022
  • Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

증발산량 관측 대표위치 선정에 관한 연구: 춘천댐 유역을 중심으로 (A study on the selection of evapotranspiration observatory representative location in Chuncheon Dam basin)

  • 박재곤;김기영;이용준;황보종구
    • 한국수자원학회논문집
    • /
    • 제55권11호
    • /
    • pp.979-989
    • /
    • 2022
  • 수문조사에서는 시·공간적 한계 및 제약으로 인하여 대표지점을 통한 관측이 필수적이다. 수문자료의 활용 및 자료의 정확성에 있어 특정 유역을 대표하는 관측소가 부족한 실정이다. 또한 현재 증발산량 측정 위치에 대한 기준이 사실상 전무하기 때문에 본 연구에서는 증발산량 측정 위치 결정에 관한 방법을 제시하고자 한다. 증발산량 측정 위치 결정은 증발산량 측정에 주로 사용되고 있는 에디공분산(eddy covariance) 측정 방법에서 관측 타워(Flux Tower) 운영범위를 고려한 격자를 선정하였으며 증발산량에 영향을 미치는 인자, 증발산량 위성자료를 통해 대표위치 격자를 산정하였다. 산정된 대표위치 격자는 양호, 보통, 미흡으로 분류하였다. 결과로 산정된 양호격자의 수는 54개이다. 격자의 분류에서 나타난 특징으로 지형, 토지이용에서 격자의 분류가 이루진 것으로 판단된다. 특히 표고나 시가지의 경우 편차가 크게 나타났으며 산정된 양호 격자는 두 분포 사이의 집단으로 판단된다.