• 제목/요약/키워드: operating characteristic

검색결과 1,733건 처리시간 0.023초

구매조건부 판토그라프 모델에 대한 공력특성 평가 (Evaluation of the Aerodynamic characteristic on the Pantograph model)

  • 김기남;조용현;고태환;권혁빈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.152-161
    • /
    • 2009
  • This thesis aims to report the result of an evaluation of the aerodynamic characteristic on the purchase conditional pantograph model that has developed for applying to the KTX-I. Development pantograph was derived the result of aerodynamic characteristic through a wind tunnel test. And design modification was proceeded to solve the difference of aerodynamic characteristic by pantograph's operating direction. The verification test and adjustment test about the modified pantograph's aerodynamic characteristic were progressed on the KTX-I. To be corresponded with requirements, the airfoil and spoiler were used.

  • PDF

전자기 해석법에 의한 직선형 스위치드 릴럭턴스 전동기의 회로정수 도출 및 동특성 해석 (Analysis on Dynamic Characteristic and Circuit Parameter of Linear Switched Reluctance Motor by Electromagnetic Analytical Method)

  • 박지훈;고경진;최장영;장석명
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.318-327
    • /
    • 2010
  • This paper deals with analysis on dynamic characteristic and circuit parameter of linear switched reluctance motor by electromagnetic analytical method. Above all, using space harmonic method, which is electromagnetic method, the air-gap flux density is analyzed in the both align and unaign positions, and the inductance profile, force characteristic and resistance per phase are calculated by means of the process. The validity of the analyzed results are demonstrated by the finite element method(FEM) and manufacture of the prototype machine. Second, the dynamic simulation is analyzed by the use of circuit parameters derived from analytical method, and the operating system of the prototype machine is manufactured to demonstrated the validity of simulation analysis. As a result, it is considered that the characteristic equation suggested in this paper will contribute to the design, analysis and application of LSRM.

고해상도 천연색 LED 디스플레이 시스템을 위한 흰색 보정프로세서의 설계 (Design of White Balance Correction Processor for High Resolution Full Color LED Display System)

  • 이종하;고덕영
    • 전자공학회논문지 IE
    • /
    • 제46권3호
    • /
    • pp.12-18
    • /
    • 2009
  • 본 논문은 LED 디스플레이 시스템에서 균일하고 부드러운 영상표출을 위하여 각각의 Red, Green, Blue LED의 휘도를 조절하여 흰색보정을 유지할 수 있는 프로세서를 설계하였다. 이 프로세서는 일반적인 LED소자의 특성곡선을 근거로 "a"를 고유특성 값, "b"를 사용시간에 따른 휘도보정 값, "X"를 구동전류 값, "Y"를 휘도 값이라 할 때, "Y=aX+b"로 설정되는 휘도 특성함수에 의하여 각 픽셀의 휘도에 따른 구동 전류 값을 산출하여 휘도를 보정하고, 또한 장시간 사용 시 LED소자의 휘도 저하 문제를 해결하기 위하여 "b"값을 조절하여 LED 디스플레이 시스템의 전체 평균 휘도 값을 상향시킬 수 있도록 구현하였다.

도시철도차량 시트의 안락성 평가 및 분석 (The comfort evaluation and analysis of the urban rail vehicle)

  • 구재광;서우성;최세화
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.222-228
    • /
    • 2007
  • In order to solve the problem of traffic holdups and environmental pollution(contamination), several metropolises are operating the subway and many local government plans hereafter the light rail vehicle operation and it is in the process of preparing. This point of time, it need to evaluate the comfortable characteristic of the seat which is closely connected with passenger and it should be reflected to the product design through the data analysis. The methods of the comfortable characteristic evaluation should be considered to various methods from physical factor to psychological factor. Among these, the most universal and possible quantitative measurement estimate through 'Body pressure measurement system'. From this paper, it was measured the body pressure of the subway seat which is in the process of operating in a domestic and it will be compared and analyzed the material & seat shape, so we evaluated the comfortable characteristic of the short-distance transportation railway vehicle. It was operated the man and woman who belongs in standard shape of Korean, we compared and analyzed the Peak position where the body pressure is visible and body pressure spread out.

  • PDF

이온 보조 반응법에 의한 친수성 처리가 충전재 특성값에 미치는 영향 (Effects of Hydrophilic Treatment by IAR Method on the Packing Characteristic Value)

  • 김진호;최충현;강병하;이재헌
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.554-560
    • /
    • 2001
  • Hydrophilic treatment of the packing materials in a cooling tower has been made by the ion assisted reaction (IAR) method to increase the wettability of the packing materials. The effects of hydrophilic treatment of packing materials on the performance of a cooling tower have been investigated in a wide range of operating parameters, such as water flow rate, air flow rate, and the water inlet temperature. A pilot cooling tower has been designed and built to model a counter-flow cooling tower. The results obtained indicate that the packing characteristic value with hydrophilic packing could be substantially increased by 6∼19.3% than that with conventional packing in the operating ranges considered. The correlations of the packing characteristic value as a function of water-to-air ratio are suggested for a counter-flow cooling tower with hydrophilic packing as well as with conventional packing.

확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구 (Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation)

  • 이철민;김윤신;이태형;김종철;김중호
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.221-229
    • /
    • 2004
  • We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

유체 순환 혈압 시뮬레이터의 구현 (Implementation of The Fluid Circulation Blood Pressure Simulator)

  • 김철한;이규원;남기곤;전계록
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.768-776
    • /
    • 2007
  • A new type of the fluid circulation blood pressure simulator was proposed to enhance the blood pressure simulator used for the development and evaluation of automatic sphygmomanometers. Various pressure waveform of fluid flowing in the pipe was reproduced by operating the proportional control valve after applying a pressure on the fluid in pressurized oil tank. After that, appropriate fluid was supplied by operating the proportional control valve, which enabled to reproduce various pressure wave of the fluid flowing in the tube. To accomplish this work, the mathematical model was carefully reviewed in cooperating with the proposed simulator. After modeling the driving signal as input signal and the pressure in internal tube as output signal, the simulation on system parameters such as internal volume, cross-section of orifice and supply pressure, which are sensitive to dynamic characteristic of system, was accomplished. System parameters affecting the dynamic characteristic were analyzed in the frequency bandwidth and also reflected to the design of the plant. The performance evaluator of fluid dynamic characteristic using proportional control signal was fabricated on the basis of obtained simulation result. An experimental apparatus was set-up and measurements on the dynamic characteristic, nonlinearity, and rising and falling response was carried out to verify the characteristic of the fluid dynamic model. Controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. Hybrid controller combined with an proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid simulator indicated that even though the former showed good control performance.

광대역 동축선로 임피던스 변환회로의 동작 특성 분석 (The analysis of the operating characteristic for the wideband coaxial line impedance transformer)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제23권2호
    • /
    • pp.165-172
    • /
    • 2019
  • 두 개 이상의 동축선을 사용하여 한 쪽은 동축선을 직렬로 연결하고, 반대 쪽은 동축선을 병렬로 연결하면 광대역에서 동작하는 임피던스 변환회로가 된다. 동축선을 이용한 광대역 임피던스 변환회로는 동축선의 외곽 도체를 임피던스 변환에 이용하기 때문에 수식 또는 시뮬레이션 프로그램을 통한 예측이 매우 어렵다. 본 논문에서는 ${\lambda}/4$-마이크로스트립 선로 임피던스 변환회로의 선로 신호 감쇄에 대한 전달 특성(S21) 해석을 바탕으로 $25{\Omega}$ 동축선 두 개를 이용한 광대역 4:1($50{\Omega}:12.5{\Omega}$) 전송선로 임피던스 변환회로를 제작하여 동작 특성을 살펴보았다. 두 개의 동축선을 이용한 광대역 임피던스 변환기는 동축선의 길이를 90도(${\lambda}/4$)로 인식하는 주파수에서 신호 전달 특성(S21)이 급격히 감소하는 노치 특성이 발생하였다. 또한, 동축선 길이의 $0.06{\sim}0.2{\lambda}$에 해당하는 주파수 범위에서 신호 전달특성(S21) -0.2dB 이내의 값을 가졌다. 이러한 신호 전달특성(S21)은 출력 단에 연결된 마이크로스트립 선로의 길이 변화를 통해 약간의 동작 주파수 범위 변화와 원하는 주파수에서 최적의 신호 전달특성(S21)을 설정할 수 있음을 확인하였다.