A Study on Cost Prediction of Highway Operating Risk through a Case Study of Power Failure (정전사고 사례분석을 통한 고속도로 운영 위험비용 산정에 대한 연구)

  • Kwon, Yong-Hoon;Kim, Kyong-Ju;Lim, Won-Seok;Park, Chan-Jin;Chae, Myung-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.1
    • /
    • pp.78-90
    • /
    • 2009
  • Recently, operation of highway is the complex digital Infrastructure based on complicated IT. The application of IT is increasing more and more in digital Infrastructure. Though IT is very convenient, if unpredicted operating risk of highway occurs, widespread damage can be large. When operating risk of highway occurs, road users are out of smoothly-run service because of the operating interruption. This risk causes unpredicted operating management cost and additional maintenance cost. It will excess over the planned operating cost, which may leads to users's unsafety and operator's insolvency because of income loss. Until now, related studies to find out the risk are not sufficient. The purpose of this study is to suggest risk cost items and to estimate the reasonable risk cost by using simulation method in case of occurring the huge power failure at the operating digitalized highway. This study indicates the several plans to hedge against risk cost and the management of highway project. From now on, it will be used as basic data to confirm the soundness of operating system in Digital Infrastructure.

Reviewing of Operating Stability about Pulse Detonation Engine's Ignition Circuit to the Type of Power Sources (점화 신호 종류에 따른 PDE 점화회로의 작동 안정성 연구)

  • Kim, Jungmin;Han, Hyung-Seok;Oh, Sejong;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.11-18
    • /
    • 2018
  • A pulse detonation engine (PDE) requires high operating frequency greater than 100 Hz to get meaning thrust as a propulsion devise. Thus a PDE needs an ignition circuit operating precisely at high operating frequencies. In this paper AC(alternating current) and DC(direct current) types of ignition circuits were designed and compared. Each circuit was tested at operating frequencies from 16.66 to 100.00 Hz by measuring the input signal of each circuit and the voltage change in the primary coil of the transformer. Results show that the DC power circuit can attain a maximum error rate of 5.15% at higher operating frequencies, whereas the AC power circuit displays a negligible agreement with the operating signal at frequencies greater than 33.33 Hz. Therefore it is confirmed that DC-powered ignition circuit is preferable for the PDE operating at high frequencies.

The Influence of Infection-related Characteristics and Patient Safety Culture on Awareness of Blood-borne Infection Prevention in Operating Room Nurses and General Ward Nurses (수술실간호사와 병동간호사의 감염관련특성과 환자안전문화가 혈행성 감염예방 인식에 미치는 영향)

  • Jeon, Hae Ok;An, Gyeong Ju;Lee, Jong Hee;Lee, Kyoung Mi
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.1
    • /
    • pp.43-54
    • /
    • 2021
  • Purpose: This study aimed to identify the factors influencing infection-related characteristics and patient safety culture on awareness of blood-borne infection prevention between operating room nurses and general ward nurses. Methods: Participants were 198 nurses(operating room nurses 98 and general ward nurses: 100) working at three general hospitals and three university hospitals in three cities. Data were collected using a structured questionnaire from September 11 to October 14, 2020. Data were analyzed using descriptive statistics, t-tests, ANOVA, Pearson's correlation coefficient, and multiple regression with IBM SPSS/WIN 26.0 program. Results: Typically, 39.8% of nurses in the operating room and 24.0% of ward nurses experienced injuries such as needles and sharp instruments used by the patient. The awareness of patient safety culture was identified to be higher for the ward nurses. Factors influencing the awareness of blood-borne infection prevention in operating room nurses were patient safety culture and wearing protective equipment for infection prevention while nursing infected patients. Moreover, the explanatory power of these variables was 19.4%. In general ward nurses, the patient safety culture was identified as a significant predictor, which accounted for 16.5% of awareness of blood-borne infection prevention. Conclusion: To prevent hospital infection, a strategy is needed to improve the level of awareness of blood-borne infection prevention and patient safety culture of operating room nurses. To this end, the difference in infection-related characteristics and influencing factors between the operating room nurses and the general ward nurses should be considered and planned.

A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent (노후화된 누전차단기의 과전류 동작 특성에 관한 연구)

  • Ye Jin Park;Sin Dong Kang;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

The Underpricing and The Long-run Performance of IPO Firms (IPO기업의 장기성과와 저가발행)

  • 황동섭;이재범
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.57
    • /
    • pp.41-49
    • /
    • 2000
  • This paper investigates the relation between operating performance and initial underpricing of companies that go public. A significant decline in operating performance subsequent to the initial public offering(IPO) is found. Additionally there is a significant positive relation between post-IPO operating performance and the level of initial underpricing.

  • PDF

A Study on the Criteria for Setting the Dynamic Control Mode of Battery Energy Storage System in Power Systems (전력계통 적용을 위한 배터리 에너지저장장치의 동적 제어모드 판단기준에 관한 연구)

  • Han, Jun Bum;U, Garam;Kook, Kyung Soo;Chang, Byunghoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.444-450
    • /
    • 2013
  • This paper presents the criteria for setting the dynamic operating mode of BESS(Battery Energy Storage System) in the bulk power systems. ESS has been expected to improve the degraded dynamic performance of the power system with high penetration of the renewable resources. While ESS is controlled in steady state or dynamic operating mode for its better effectiveness depending on the operating conditions of power systems, the criteria for setting the dynamic operating mode for the transient period needs to be robust enough to cover all the different conditions. The proposed criteria consider the varying conditions and the operating practices of the bulk power systems.

Design of Field Coil for High Temperature Superconducting motor considering Operating Current (운전전류를 고려한 고온초전도 모터용 계자코일의 설계)

  • 조영식;서무교;백승규;김석환;손명환;권영길;홍정표
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.315-317
    • /
    • 2002
  • The value of I$_{c}$(critical current) in HTS (High Temperature Superconducting) tape has a great influence on B(equation omitted) (magnetic field amplitude applied perpendicular to the tape surface). Therefore, I$_{c}$ of HTS magnet is determined by not only operating temperature but also the B(equation omitted). In shape design of field coil for the HTS motor, a method to reduce the B(equation omitted) and to determine operating current should be considered in order to optimal design. On the basis of the magnetic field analysis, this paper deals with various field coil shape to obtain operating current of HTS motor by using analytical method. And also this paper discusses the operating current of 100hp class HTS motor by using I$_{c}$-B(equation omitted) curve.curve.

  • PDF

A New Linearized Equation for Modelling a Servovalve in Hydraulic Control Systems (유압 제어계에서 서보밸브 모델링을 위한 새로운 선형화 방정식의 제안)

  • Kim, Tae-Hyung;Lee, Ill-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.789-797
    • /
    • 2003
  • In the procedure of the hydraulic control system design, a linearized approximate equation described by the first order terms of Taylor series has been widely used. Such a linearized equation is effective just near the operating point, However, pressure and flowrate in actual hydraulic systems are usually not confined near an operating point. This study suggests a new linearized flow equation for a servovalve as a modified form of the conventional linearized flow equation. Subsequently, a procedure to determine effective operating point for the new linearized equation is proposed. From the evaluations of time responses and frequency responses obtained from simulations for a hydraulic control system, the effectiveness of the new linearized equation and the procedure to determine effective operating point is confirmed.

Comparative Evaluation of Multipurpose Reservoir Operating Rules Using Multicriterion Decision Analysis Techniques

  • Ko, Seok-Ku;Lee, Kwang-Man;Ko, luk-Hwan
    • Korean Journal of Hydrosciences
    • /
    • v.4
    • /
    • pp.65-79
    • /
    • 1993
  • Selection of the best operating rule among a set of alternatives for a multipurpose reservoir system operation requires to evaluate many minor criteria in addition to the major objectives assessed to the system. These problems are sufficiently complex and difficult that they are beyond heuristic decision rules and experiences in case several noncommensurable multiple criteria are included in the evaluation. With the assistance of multicriterion decision analysis techniques, it is possible to select the best one among various alternatives by systematically comparing and ranking the alternatives with respect to the criteria of choice. Evaluation criteria for multipurpose reservoir system operating rules were identified and defined, and the multicriterion decision analysis techniques were applied to evaluate the four existing operating rules of the Chungju multipurpose project according to the identified nine multiple criteria. The application results show that the methodology is very efficient to select the best operation alternative among a finite number of operating rules with many evaluation criteria for a large-scale reservoir system operation.

  • PDF

Application of Air-Borne Noise Path Analysis to a real vehicle (실차에 대한 공기기인 소음경로분석법 적응)

  • Kim, Yoon-Jae;Jeong, Won-Tae;Song, Moon-Seong;Kang, Yeon-June;Kim, Hong-Bin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.699-702
    • /
    • 2006
  • Noise Path Analysis is commonly used method to analysis noise transmission characteristics of a system. To analysis transfer paths of a system, it is necessary to know operating forces at each transfer path. The method to find out operating forces is divided into two methods. The one is a direct method which measures operating forces directly and the other is an indirect method which estimates operating forces mathematically. However, the indirect method is more commonly used because of the difficulty of measurement. This paper is focused on the indirect method and air-borne noise of a vehicle. Noise Path Analysis for Air-Borne Noise is applied to a real vehicle.

  • PDF