• 제목/요약/키워드: operability

검색결과 407건 처리시간 0.038초

하나로 2 차 냉각탑의 공장분해수리 (Cooling Tower Overhaul of Secondary Cooling System in HANARO)

  • 박용철;이용섭;김양곤;정환성;임인철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2714-2719
    • /
    • 2007
  • HANARO, an open-tank-in-pool type research reactor of 30 MWth power in Korea, has been operating normally since its initial criticality in February, 1995. For the last about ten years, A cooling tower of a secondary cooling system has been operated normally in HANARO. Last year, the cooling tower has been overhauled for preservative maintenance including fills, eliminators, wood support, water distribution system, motors, driving shafts, gear reducers, basements, blades and etc. This paper describes the results of the overhaul. As results, it is confirmed that the cooling tower maintains a good operability through a filed test. And a cooling capability will be tested when a wet bulb temperature is maintained about 28 $^{\circ}C$ in summer and the reactor is operated with the full power.

  • PDF

열차제어시스템(ETCS Level 2)개발 현황과 향후 과제 (Train Control System (ETCS Level 2) Development Status and Future Challenges)

  • 이시빈;김철환;이승철;김범곤;강병욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1066-1076
    • /
    • 2011
  • The subsystems of HSR train control system in each country has developed and operated till early 2000, however 2001/16/EC ERTMS is issued for inter-operability among European train control systems in 2001. So it is trend that ERTMS/ETCS has been applied to not only low-speed train system but high-speed train system over 300km/h in many countries of Europe. According to the government policies of the Honam HSR, metropolitan HSR and test lines, incoming on-board signal control system has been required caused by speed limit to 160km/h on the ground signal system. As ETCS-Level 1 system has applied in our railways from 2003, so our train control system has depended on foreign technologies. In this paper, we analyzed to localize train control system for being ready to protect foreign policies and obtaining core technologies of HSR train control system for instance ETCS-Level2.

  • PDF

마이크로가스터빈용 환형연소기 설계 기법 (Design Methodology of an Annular Combustor for Micro Gas Turbines)

  • 조주형
    • 한국연소학회지
    • /
    • 제19권4호
    • /
    • pp.21-27
    • /
    • 2014
  • MGT (micro gas turbines) have been gaining particular attentions with a variety of commercial and military applications due to their advantages such as compact size, simple operability, easy maintenance, and low emissions. This study deals with development processes of an annular combustor applied to MGT. Preliminary design methodologies are used to size the main components of the combustor. Key design features such as liner temperatures and pressure losses are evaluated. Results show that the estimated liner temperatures are within acceptable range. Dominant factors for pressure losses are estimated to be air admission holes and burner swirlers.

석탄 IGCC 다이내믹 시뮬레이션에 관한 연구 (Study on the Dynamic Simulation for an Integrated Coal Gasification Combined Cycle)

  • 주용진;김시문;이민철;김미영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.106.2-106.2
    • /
    • 2010
  • IGCC (Integrated Gasification Combined Cycle) plants are among the most advanced and effective systems for electric energy generation. From a control perspective, IGCC plants represent a significant challenge: complex reactions, highly integrated control to simultaneously satisfy production, controllability, operability and environmental objectives. While all these requirements seem clearly to demand a multivatiable, model predictive approach, not many applications can be easily found in the literature. This paper describes the IGCC dynamic simulation that is capable of simulating plant startup, shutdown, normal, and abnormal operation and engineering studies. This high fidelity dynamic models contain the detailed process design data to produce realistic responses to process operation and upset. And the simulation is used by engineers to evaluate the transient performance and produce graphical information indicating the response of the process under study conditions.

  • PDF

원자력발전소 보호시스템 캐비넷의 내진검증 (Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant)

  • 정명조;황원걸
    • 전산구조공학
    • /
    • 제6권2호
    • /
    • pp.79-86
    • /
    • 1993
  • 원자력발전소중 안전과 관련된 구조물은 지진의 가능성에 대비하여 그의 구조적 안전성과 가용성이 검증되어야 한다. 본 논문은 원자력발전소 보호시스템 캐비넷을 예를 들어 그에 대한 내진검증 방법을 보였다 캐비넷의 유한요소모델을 작성하여 동특성을 구하였고 그 모우드값을 입력지진스펙트럼과 비교한 결과 구조물의 1차 모우드가 입력 스펙트럼의 peak와 일치함으로써 설계변경의 필요성이 대두되었다. 이 peak값을 피하기 위하여 캐비넷의 구조를 변경하였고 변경된 구조물에 대하여 응답스펙트럼해석과 시간이력해석을 수행하여 구조적 건전성과 가용성을 보임으로써 설계변경된 캐비넷의 내진검증을 확인하였다.

  • PDF

이종 무선 메쉬 네트워크 설계 및 성능평가 (Design and Evaluation of Hybrid Wireless Mesh Networks)

  • 김태우;곽정남;강남희;김영한
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.257-260
    • /
    • 2005
  • In this paper we design and evaluate Hybrid Wireless Mesh Networks on IEEE 802.11-based network. So we analysis the CWMNs and BWMNs to integrate them. The CWMNs of Ad hoc Mode cannot be directly connected to the BWMNs of Infrastructure Mode because they have different frame types. We propose the new effective HWMNs scheme using DYMO than OLSR protocol for the inter-operability and the mobility

  • PDF

Circuit card inspection method through digital circuit design based AITS

  • Han, Ji-Hoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권8호
    • /
    • pp.1-7
    • /
    • 2018
  • Previous test equipment was bulky, took a long time to check, and was somewhat less economical. Since most of the checks were about analog signals, we preferred to check them using reference equipments. In this paper, a digital circuit design based on AITS is used to implement signals that can not utilize commercial measurement resources, and also designed and manufactured equipment that can inspect SRU. These test equipments were tested and evaluated by development, operation, and field evaluation, and they were installed to the Korean Field Force. This contributed to the improvement of operability by shortening the inspection time from 83.2 minutes to 7.8 minutes on average In addition, it did not utilize the reference equipment, so it could play a big role in lowering the mass production cost.

Experimental assessment of slamming coefficients for subsea equipment installations

  • de Oliveira, Allan C;Pestana, Rafael G
    • Ocean Systems Engineering
    • /
    • 제10권2호
    • /
    • pp.163-179
    • /
    • 2020
  • Considering the huge demand of several types of subsea equipment, as Christmas Trees, PLEMs (Pipeline End Manifolds), PLETs (Pipeline End Terminations) and manifolds for instance, a critical phase is its installation, especially when the equipment goes down through the water, crossing the splash zone. In this phase, the equipment is subject to slamming loads, which can induce impulsive loads in the installation wires and lead to their rupture. Slamming loads assessment formulation can be found in many references, like the Recommended Practice RP-N103 from DNV-GL (2011), a useful guide to evaluate installation loads. Regarding to the slamming loads, RP-N103 adopt some simplifying assumptions, as considering small dimensions for the equipment in relation to wave length, in order to estimate the slamming coefficient CS used in load estimation. In this article, an experimental investigation based on typical subsea structure dimensions was performed to assess the slamming coefficient evaluation, considering a more specific scenario in terms of application, and some reduction of the slamming coefficient is achieved for higher velocities, with positive impact on operability.

원자력 발전소 모터구동밸브의 쓰러스트/토크 신호 분석 (Analysis of Thrust/Torque Signature of MOV)

  • 류호근;박성근;김대웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.613-618
    • /
    • 2001
  • For the evaluation of operability of MOV(Motor Operated Valve), the precision prediction of thrust/torque acting on the valve is important. In this paper, the analytical prediction method of thrust/torque was proposed. The design basis stem thrust calculation typically considers the followings: Packing thrust, Stem rejection load, design basis differential pressure load. In general, test results show that temperature, pressure, fluid type, and differential pressure, independently and combination, all have an effect on the friction factor. The prediction results of thrust/torque are well agrement with dynamic test results.

  • PDF

피동형 원자로의 Hydraulic Valve 특성 실험 (The Characteristics of Hydraulic Valve for a Passive Reactor)

  • 김상녕;김융석
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1083-1090
    • /
    • 1998
  • A kind of three-way check valve, so called hydraulic calve was proposed for the substitute of the density lock of passive reactor such as SPWR (System-Integrated Pressurized Water Reactor). The function of the valve are the separation of the borated water from main coolant loop for normal operation and the insurge of the water into the loop for shutdown and the removal of the decay power when the main coolant flow rate is not enough. To verify the operability and the characteristics of the valve, experimental works were executed with 1/3 scale model calve. Also a diffuser model was proposed for the theoretical analysis of the valve.