• Title/Summary/Keyword: opening ratio

Search Result 620, Processing Time 0.028 seconds

Survey on the Physical Environment of Welfare Facilities for the Aged of the Jeju Province -Focused on the free home for the aged and free nursing home- (제주도 노인복지시설의 물리적 환경에 대한 실태조사 -무료 노인홈과 무료 요양원을 중심으로-)

  • 김봉애
    • Journal of the Korean housing association
    • /
    • v.11 no.4
    • /
    • pp.35-42
    • /
    • 2000
  • The purpose of this study is to prepare desirable elderly housing facilities system in compliance with various characteristics of each region and to help establish policies regarding elderly housing facilities. Present realities and problems of the eight free welfare facilities of two sorts, a free home for the aged and free nursing home in Jeju Province have been studied. In Jeju Province, the average life span and the ratio of the aged people older than 65 are longer and higher than other provinces and the mentality of self-reliance is more widespread. The results are as follows : 1) The average age of the aged is 70 or older and more facilities are located in rural districts. 2) Some facilities are located in the places where are not adequate for life of the aged, and not even suitable as welfare facilities for the aged. 3) Housing environmental conditions of the facilities are relatively good, while indoor facilities for recreation and social life were not well equipped. 4) Life in the facilities can be assessed relatively free, while individual privacy is not well protected. 5) Major community contacting activities included home help service, participation in regional activities, opening facilities to the community.

  • PDF

Reducing the Effects of Noise Light in an Wireless Optical Communication Using Optoelectronic Feedback (무선 광통신에서 광전 궤환을 이용한 잡음 광의 영향 감소)

  • Hwang, Da-Hyun;Lee, Seong-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1136-1142
    • /
    • 2010
  • In this paper, we reduced the optical noise interference using the ASK modulation with optoelectronic feedback in a wireless optical system in which a lighting LED is used as a light source. The carrier frequency of 70 kHz was generated internally by the oscillation in the optoelectronic feedback circuit, and the output light was ASK modulated at a data rate of 9.6 kbps by opening and shortening the feedback loop with the input signal. In an environment with adjacent noise lights, the ASK modulation with optoelectronic feedback improved the signal to noise ratio by about 25 dB.

A Study on Corrosion Fatigye Crack Propagation Behaviors due to a Single Overload (단일과대하중하의 부식피로균열진전거동에 관한 연구)

  • 강동명;이하성;우창기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.481-485
    • /
    • 1997
  • 6063-T5 alloys are tested in laboratory air, water and 3% NaCl solution to investigate the effects of corrosive environment on the retardation behavior through single overload fatigue test. Also, the fatigue crack propagation and the crack closure behavior are studied. The results obtained in this experimental study are summarized as follows: 1) Behaviors of fatigue crack growth retardation are observed in water and 3% NaCl solution as they do in air. The number of delay cycles and the size of affected region by single overload decrease greatly in water and 3% NaCl compared with those in air. 2) In fractographic results, the overload marking by single overload appear remarkably in air, but indistinctly in water and 3% NaCl solution. 3) The effect of crack closure on crack propagation is most remarkable in the beginning of crack propagation. With crack propagation, the crack closure level and its effect decrease greatly.

  • PDF

An Empirical Analysis on the Service Quality of the National Library of Korea and Its Effect (국립중앙도서관의 서비스품질과 그 효과에 대한 실증적 분석)

  • Han, Sang-Il;Kim, Young-Jea;Yu, Pyeong-Jun;Bae, Deuk-Jong
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.42 no.1
    • /
    • pp.295-311
    • /
    • 2008
  • The authors examine the service quality of the National Library of Korea and its effects on the customer satisfaction and the annual number of visit. In particular this article tests the actual effects of the extension of opening hour that has been famous for increasing ratio of library operation and employing more librarians. A survey of 332 customers was conducted to measure individual perceptions on the customer service and satisfactions and estimate structural equation models across two time slots: the daytime, and night hour. The major findings of this study are that the service quality tends to increase customer satisfaction.

Mechanical and fracture properties of glass fiber reinforced geopolymer concrete

  • Midhuna, M.S.;Gunneswara Rao, T.D.;Chaitanya Srikrishna, T.
    • Advances in concrete construction
    • /
    • v.6 no.1
    • /
    • pp.29-45
    • /
    • 2018
  • This paper investigates the effect of inclusion of glass fibers on mechanical and fracture properties of binary blend geopolymer concrete produced by using fly ash and ground granulated blast furnace slag. To study the effect of glass fibers, the mix design parameters like binder content, alkaline solution/binder ratio, sodium hydroxide concentration and aggregate grading were kept constant. Four different volume fractions (0.1%, 0.2%, 0.3% and 0.4%) and two different lengths (6 mm, 13 mm) of glass fibers were considered in the present study. Three different notch-depth ratios (0.1, 0.2, and 0.3) were considered for determining the fracture properties. The test results indicated that the addition of glass fibers improved the flexural strength, split tensile strength, fracture energy, critical stress intensity factor and critical crack mouth opening displacement of geopolymer concrete. 13 mm fibers are found to be more effective than 6 mm fibers and the optimum dosage of glass fibers was found to be 0.3% (by volume of concrete). The study shows the enormous potential of glass fiber reinforced geopolymer concrete in structural applications.

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

Study on Statistical Analysis of Measured Fluid Leakage Data and Estimation of the Leakage Rate for Power Plant Valve (발전용 밸브 유체누설 측정 데이터의 통계적 평가 및 누설량 예측 연구)

  • Lee, S.G.;Kim, D.W.;Kim, Y.S.;Park, J.H;Jeong, H.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2009
  • High temperature and pressure valves in power plant have been used for fluid flowing and leakage occurred owing to valve internal damage such as disc wear, crack and inserting of foreign objects etc. in these valves. Recently, multi-measuring technique applied both ultrasonic and acoustic method have been used for evaluation of valve internal leakage in order to raise measurement reliability. Therefore, we have performed various leakage tests using ultrasonic and acoustic measuring system and acquired leakage data for the various leakage conditions. In this study, we developed the estimation method of regression model through leakage data, and expectation method for valve opening ratio, which is directly proportion to leakage rate, using the established estimation model from the measured data, valve size and fluid pressure so as to enhance data reliability. As a result of this study, it was founded that expectation method of leakage rate by statistical analysis method is appropriate to valve leakage evaluation.

  • PDF

Operation characteristics of SFCLs combined with a transformer in three-phase power system

  • Jung, B.I.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.30-33
    • /
    • 2013
  • The studies of superconducting fault current limiter (SFCL) for reduction of the fault current are actively underway in the worldwide. In this paper, we analyzed the characteristics of a new type SFCL using the conventional transformer and superconducting elements combined mutually. The secondary and third windings of this SFCL were connected the load and the superconducting element, respectively. The electric power was provided to load connected to secondary windings of the transformer in normal state of power system. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the ripple phenomenon of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the CT(current transformer) and then turn-on and turn-off switching behavior of the SFCL was performed by the SCR(silicon-controlled rectifier). As a result, the proposed SFCL limited the fault current within a half-cycle efficiently. We confirmed that the fault current limitation rate was changed according to the winding ratio of a transformer.

A Parametric Study for the Design of Gas-Liquid Centrifugal Separator (기체-액체 원심분리기의 설계를 위한 매개변수 연구)

  • Nagdewe, Suryakant;Lee, S.J.;Kim, H.D.;Kim, D.S.;Kwak, K.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.218-219
    • /
    • 2008
  • A gas-liquid centrifugal separator is widely used in industry because of its simple geometry and little maintenance. Also, these separators have considerable advantages over filters, scrubbers or precipitators in term of compact design, low pressure drop and higher capacity. A gas-liquid centrifugal separator is a device that utilizes centrifugal force and low pressure to separate liquid from gas by density difference. Design parameters such as length of separation space, swirl vane exit angle, inlet to outlet pipe diameter ratio, models for separation efficiency and low pressure drop as a function of physical dimension are not available in literature. In present study, length of separation space (from vane to gas exit opening) has been studied using CFD. The 3-D Navier-Stokes equations are numerically solved using a fully implicit finite volume scheme. Based upon the obtained solutions, tangential velocities, centrifugal forces, vortices and total pressure losses are analyzed to find the best design parameters.

  • PDF

An Investigation on the Shot Peening on the Low.High Temperature Fatigue Crack Propagation (쇼트피이닝 가공된 스프링강의 저.고온 피로균열진전 평가)

  • 박경동;정찬기
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.65-70
    • /
    • 2001
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature, low temperature and high temperature experiment. And we got the following characteristics from fatigue crack growth test carried out in the environment of room, low temperature and high temperature at $25^{\circ}C$, -3$0^{\circ}C$, -5$0^{\circ}C$, -7$0^{\circ}C$, -10$0^{\circ}C$ and 5$0^{\circ}C$, 10$0^{\circ}C$ , 15$0^{\circ}C$, 18$0^{\circ}C$ and in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range $\DeltaK_{th}$ in the early stage of fatigue crack growth (Region I ) and stress intensity factor range ΔK in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

  • PDF