• Title/Summary/Keyword: opening operator

Search Result 35, Processing Time 0.029 seconds

Shape Extraction of Near Target Using Opening Operator with Adaptive Structure Element in Infrared hnages (적응적 구조요소를 이용한 열림 연산자에 의한 적외선 영상표적 추출)

  • Kwon, Hyuk-Ju;Bae, Tae-Wuk;Kim, Byoung-Ik;Lee, Sung-Hak;Kim, Young-Choon;Ahn, Sang-Ho;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.9C
    • /
    • pp.546-554
    • /
    • 2011
  • Near targets in the infrared (IR) images have the steady feature for inner region and the transient feature for the boundary region. Based on these features, this paper proposes a new method to extract the fine target shape of near targets in the IR images. First, we detect the boundary region of the candidate targets using the local variance weighted information entropy (WIE) of the original images. And then, a coarse target region can be estimated based on the labeling of the boundary region. For the coarse target region, we use the opening filter with an adaptive structure element to extract the fine target shape. The decision of the adaptive structure element size is optimized for the width information of target boundary by calculating the average WIE in the enlarged windows. The experimental results show that a proposed method has better extraction performance than the previous threshold algorithms.

Minimal clinically important difference of mouth opening in oral submucous fibrosis patients: a retrospective study

  • Kaur, Amanjot;Rustagi, Neeti;Ganesan, Aparna;PM, Nihadha;Kumar, Pravin;Chaudhry, Kirti
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.3
    • /
    • pp.167-173
    • /
    • 2022
  • Objectives: The purpose of this study was to estimate the minimal clinically important difference (MCID) of mouth opening (MO) and patient satisfaction in surgically treated oral submucous fibrosis (OSMF) patients. Materials and Methods: The status of MO was collected preoperatively (T0), postoperatively at 3 months (T1), and at a minimum of 6 months postoperatively (T2). MCID was determined through the anchor-based approach with the change difference method, mean change method, and receiver operator characteristic curve (ROC) method. Results: In this study, 35 patients enrolled and completed postoperative follow-up (T2) averaging a duration of 18.1 months. At T1, using the change difference method, MO was 14.89 mm and the ROC curve exhibited a 11.5 gain in MO (sensitivity 81.8% and specificity 100%, area under the curve [AUC] of 0.902) and was classified as MCID as reported by patients. At T2, MCID of MO was 9.75 mm using the change difference method and 11.75 mm by the mean change method. The ROC curve revealed that the MCID of MO at T2 was 10.5 mm with 73.9% sensitivity and 83.3% specificity (AUC of 0.873). The kappa value was 0.91, confirming reliability of the data. Conclusion: This study demonstrated MCID values that indicate the clinical relevance of surgical treatment of OSMF if the minimum possible gain in MO is approximately 10 mm.

Concerning the Constitution Court's constitutional decision and the direction of supplemental legislation concerning Article 33 paragraph 8 of the Medical Service Act - With a focus on legitimacy of a system that prohibits multiple opening of medical instituion, in the content of 2014Hun-Ba212, August 29, 2019, 2014Hun-Ga15, 2015Hun-Ma561, 2016Hun-Ba21(amalgamation), Constitutional Court of Korea - ('의료법 제33조 제8항 관련 헌법재판소의 합헌결정'에 대한 평가 및 보완 입법 방향에 대하여 -헌법재판소 2019. 8. 29. 2014헌바212, 2014헌가15, 2015헌마561, 2016헌바21(병합) 결정의 내용 중 의료기관 복수 개설금지 제도의 당위성 및 필요성을 중심으로-)

  • KIM, JOON RAE
    • The Korean Society of Law and Medicine
    • /
    • v.20 no.3
    • /
    • pp.143-174
    • /
    • 2019
  • Our Constitution obliges the state to protect the health of the people, and the Medical Law, which embodied Constitution, sets out in detail the matters related to open the medical institution, and one of them is to prohibit the operation of multiple medical institutions. By the way, virtually multiple medical institutions could be opened and operated because the Supreme Court had interpreted that several medical institutions could be opened if medical activities were not performed directly at the additional medical institution which was opened under the another doctor's license. However, some health care providers opened the several medical institutions with another doctor's license for the purpose of the maximization of profit, and did illegal medical cares like the unfair luring of patients, over-treatment, and commission treatment. Also, realistic problems such as the infringed health rights have arisen. Accordingly, lawmakers had come to amend the Medical Law to readjust the system of opening for medical institution so that medical personnel could not open or operate more than one medical institution for any reason. For this reason, the Constitutional Court recently declared a constitutional decision through a long period of in-depth deliberation because the constitutional petition and the adjudication on the constitutionality of statutes had been filed on whether Article 33 paragraph 8 of the revised medical law is unconstitutional. The Constitutional Court acknowledged the "justice of purpose" in view of the importance of public medical institutions, of the prevention from seduction of for-profit patients and from over-treatment, and of the fact that health care should not be the object of commercial transactions. Given the risk that medical personnel might be subject to outside capital, the concern that the holder of the medical institution's opening certificate and the actual operator may be separated, the principle that the human body and life should not be just a means, and the current system's inability to identify over-treatment, it also acknowledged the 'minimum infringement'. Furthermore, The Constitutional Court judged it is constitutional in compliance with the principle of restricting fundamental rights, such as 'balance of legal interests'. In this regard, legislative complements are needed in order to effectively prevent the for-profit management and the over-treatment the Constitutional Court is concerned about. In this regard, consumer groups actively support the need for legislation, and health care providers groups also agree on the need for legislation. Therefore, the legislators should respect the recent Constitutional Court's decision and in the near future complete the complementary legislation to reflect the people's interests.

Evaluating Reverse Logistics Networks with Centralized Centers : Hybrid Genetic Algorithm Approach (집중형센터를 가진 역물류네트워크 평가 : 혼합형 유전알고리즘 접근법)

  • Yun, YoungSu
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.4
    • /
    • pp.55-79
    • /
    • 2013
  • In this paper, we propose a hybrid genetic algorithm (HGA) approach to effectively solve the reverse logistics network with centralized centers (RLNCC). For the proposed HGA approach, genetic algorithm (GA) is used as a main algorithm. For implementing GA, a new bit-string representation scheme using 0 and 1 values is suggested, which can easily make initial population of GA. As genetic operators, the elitist strategy in enlarged sampling space developed by Gen and Chang (1997), a new two-point crossover operator, and a new random mutation operator are used for selection, crossover and mutation, respectively. For hybrid concept of GA, an iterative hill climbing method (IHCM) developed by Michalewicz (1994) is inserted into HGA search loop. The IHCM is one of local search techniques and precisely explores the space converged by GA search. The RLNCC is composed of collection centers, remanufacturing centers, redistribution centers, and secondary markets in reverse logistics networks. Of the centers and secondary markets, only one collection center, remanufacturing center, redistribution center, and secondary market should be opened in reverse logistics networks. Some assumptions are considered for effectively implementing the RLNCC The RLNCC is represented by a mixed integer programming (MIP) model using indexes, parameters and decision variables. The objective function of the MIP model is to minimize the total cost which is consisted of transportation cost, fixed cost, and handling cost. The transportation cost is obtained by transporting the returned products between each centers and secondary markets. The fixed cost is calculated by opening or closing decision at each center and secondary markets. That is, if there are three collection centers (the opening costs of collection center 1 2, and 3 are 10.5, 12.1, 8.9, respectively), and the collection center 1 is opened and the remainders are all closed, then the fixed cost is 10.5. The handling cost means the cost of treating the products returned from customers at each center and secondary markets which are opened at each RLNCC stage. The RLNCC is solved by the proposed HGA approach. In numerical experiment, the proposed HGA and a conventional competing approach is compared with each other using various measures of performance. For the conventional competing approach, the GA approach by Yun (2013) is used. The GA approach has not any local search technique such as the IHCM proposed the HGA approach. As measures of performance, CPU time, optimal solution, and optimal setting are used. Two types of the RLNCC with different numbers of customers, collection centers, remanufacturing centers, redistribution centers and secondary markets are presented for comparing the performances of the HGA and GA approaches. The MIP models using the two types of the RLNCC are programmed by Visual Basic Version 6.0, and the computer implementing environment is the IBM compatible PC with 3.06Ghz CPU speed and 1GB RAM on Windows XP. The parameters used in the HGA and GA approaches are that the total number of generations is 10,000, population size 20, crossover rate 0.5, mutation rate 0.1, and the search range for the IHCM is 2.0. Total 20 iterations are made for eliminating the randomness of the searches of the HGA and GA approaches. With performance comparisons, network representations by opening/closing decision, and convergence processes using two types of the RLNCCs, the experimental result shows that the HGA has significantly better performance in terms of the optimal solution than the GA, though the GA is slightly quicker than the HGA in terms of the CPU time. Finally, it has been proved that the proposed HGA approach is more efficient than conventional GA approach in two types of the RLNCC since the former has a GA search process as well as a local search process for additional search scheme, while the latter has a GA search process alone. For a future study, much more large-sized RLNCCs will be tested for robustness of our approach.

Trajectory Control of Excavator Actuators Using IMV (IMV를 이용한 굴착기 작업장치 궤적제어)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.45-54
    • /
    • 2020
  • The IMV is a combination of four two-way valve systems which replace a conventional four-way spool valve to improve efficiency mostly in excavator hydraulics. As the environmental regulations for construction equipment have tightened, some overseas advanced companies have released commercial excavators in which the MCV is implemented with the IMVs. Development of the IMV type MCV relies on the control algorithm as well as the robust performance of proportional flow control valves. In this study, the IMV controller was designed and verified with experiments for the excavator working unit, which determines the IMV mode of operation and the extent of the valve opening in consideration of the load conditions on hydraulic actuators. First, the open-loop controller was designed with a joystick command vs. a PSV reference current map comprising several control parameters in to compensate for the different flow characteristics and non-linearities of two-way flow control valves. Second, the closed-loop controller was designed with the PI control fed by the actuator displacement and outputs actuator percent effort equivalent to the operator's joystick command. Finally, the performance of the IMV type MCV was verified with the trajectory control of position references derived from the energy consumption test standard. Experimental results showed the control performance of the IMV developed in this study, and suggest that future studies to be conducted to advance technical progress.

Study of International trend for AUGT(Automated Urban Guided Transport) safe requirements (AUGT 안전요구사항의 국제적 동향 연구)

  • Lee, Hoon-Goo;Choi, Kwon-Hee;Jo, Yong-Gyun;Lee, Young-Ho;Hwang, Hyeon-Chyeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.195-197
    • /
    • 2009
  • It is a proven fact with the opening of the Seoul metro line number 1 in 1974 traffic congestion on the roads has decreased and the efficiency of people transportation in general has greatly been enhanced in the downtown and surrounding areas of Seoul. Even today construction of new subway lines are under way and many more are being planned due to the easy access to stations, short waiting and average travel times, compared with personal vehicles, contributing to the efficiency of the public transportation systems that are linking the downtown areas and also the intercity systems in moving passengers during rush hour and times of special event. Since the labour costs of the train operator in any large city based subway system accounts for a major part of the operating costs per kilometer and to ensure cost efficient operations, especially during non-peak hours, it is necessary to implement an unmanned(auto-driven) subway system. In order to implement such a system it is imperative that the on-board and wayside signalling control systems be fully automated as well. Only through proper examination of safety procedures not only by the AUGT(Automated Urban Guided Transport)system but also by ail the international standards organizations involved can safely and stability be ensured.

  • PDF

The Modernization of Automatic Control facilities of Hydro Power Plant (수력발전소 자동제어설비의 현대화)

  • Kwon, O-Geuk;Kwon, Young-June;Song, Young-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.69-70
    • /
    • 2008
  • Automatic control systems(AVR, Governor, Synchronizer) installed $1970{\sim}1980$ in K-water were considered to be rehabilitated around 2000. Moreover, Korea Power Exchange market system was changed from PPA (Power Purchase Agreement) to a bidding system. Therefore, depending on the power quality, the power provider could achieve additional profits. It is the excitation system and governor that have the functions of enhancing power necessities. During the 20 to 30 years of generator operation, there were many major and minor problems. Examples are SCR burnout (Andong: Excitation system), hunting (Imha: governor), field circuit breaker failure (Chungju 1st: excitation system), the rise of leakage current (Chungju 2nd: excitation system), power supply burnout (Chungju 2nd: governor). These are the typical examples of malfunction which hindered the generator operation and, consequently, diminished the profit of power business. In order to satisfy the needs of the power market and prevent malfunctions mentioned above, the rehabilitation of AVRs and governors were executed. A new system was made to have the flexibility of ancillary service (GF, AGC, etc.), PSS function. With user friendly HMI software, it is more convenient for the operator to fulfill suitable maintenance. It was possible to connect SCADA system by opening protocol of AVR, governor for the efficiency of operation and maintenance.

  • PDF

Simulation of Multiple Steam Generator Tube Rupture (SGTR) Event Scenario

  • Seul Kwang Won;Bang Young Seok;Kim In Goo;Yonomoto Taisuke;Anoda Yoshinari
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.179-190
    • /
    • 2003
  • The multiple steam generator tube rupture (SGTR) event scenario with available safety systems was experimentally and analytically evaluated. The experiment was conducted on the large scaled test facility to simulate the multiple SGTR event and investigate the effectiveness of operator actions. As a result, it indicated that the opening of pressurizer power operated relief valve was significantly effective in quickly terminating the primary-to-secondary break flow even for the 6.5 tubes rupture. In the analysis, the recent version of RELAP5 code was assessed with the test data. It indicated that the calculations agreed well with the measured data and that the plant responses such as the water level and relief valve cycling in the damaged steam generator were reasonably predicted. Finally, sensitivity study on the number of ruptured tubes up to 10 tubes was performed to investigate the coolant release into atmosphere. It indicated that the integrated steam mass released was not significantly varied with the number of ruptured tubes although the damaged steam generator was overfilled for more than 3 tubes rupture. These findings are expected to provide useful information in understanding and evaluating the plant ability to mitigate the consequence of multiple SGTR event.

A study on an improvement of indoor cooling tower efficiency (지하역사 실내형 냉각탑 성능개선 연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun;Pyo, Soo-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1726-1735
    • /
    • 2008
  • Seoulmetro has operated the air cooling equipment for 57 stations to improve services focused on our customers who use Seoulmetro during the summer season and has established every year. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. The most important matter is loss of efficiency in the cooling tower. The leading cause of this problem is that we use an indoor type. As the cooling tower room is located in the underground of the city because of the residents near the station. Therefore It is difficult to establish the cooling tower on the ground. But it is unsuitable for the location requirements of the underground type because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. To prevent this situation, the operator tend to reduce refrigerant. Accordingly, the efficiency of the air conditioning is getting lower and lower. Study wishes to analyze the matter to improve indoor cooling tower efficiency and recommend a best practice for a person who manage the establishment.

  • PDF

Multi-scale Crack Detection Using Scaling (스케일링을 이용한 다중 스케일 균열 검출)

  • Kim, Young-Ro;Oh, Tae-Myung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.194-200
    • /
    • 2013
  • In this paper, we propose a multi-scale crack detection method using scaling. It is based on morphology algorithm, crack features, and scaling. We use a morphology operator which extracts patterns of crack. It segments cracks and background using opening and closing operations. Morphology based segmentation is better than existing integration methods using subtraction in detecting a crack it has small width. However, morphology methods using only one structure element could detect only fixed width crack. Thus, we use a scaling method. We use bilinear interpolation for scaling. Our method calculates values of properties such as the number of pixels and the maximum length of the segmented region. We decide whether the segmented region belongs to cracks according to those data. Experimental results show that our proposed multi-scale crack detection method has better results than those of existing detection methods.