• Title/Summary/Keyword: opening and closing operation

Search Result 76, Processing Time 0.272 seconds

Improvement of detecting speed of small target using SAD algorithm (SAD 알고리즘을 이용한 소형표적 검출속도 개선)

  • Son, Jung-Min;Ahn, Sang-Ho;Kim, Jong-Ho;Kim, Sang-Kyoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.4
    • /
    • pp.53-60
    • /
    • 2013
  • We propose a method for improving detection speed of small target detection system using SAD algorithm. First, the proposed method deletes clutters using a median filter. Next, it does closing and opening operation using various size of structure elements, and extracts candidate pixels for a target with subtraction operation between the results of closing and opening operation. It finally detects a small target using a gaussian distance function from the candidate pixels. To improve detection speed, it detects a target performing SAD algorithm only for the predicted target areas for next every 7 frames. The proposed method not only enables a real time process because it considers only predicted area but also shows detecting rate of 97%.

Current Status and Reasons for the Location Change of Primary Medical Institutions in Korea (일차의료기관의 이동 현황과 이에 영향을 미치는 요인에 대한 연구)

  • Shin, Soon-Ae;Lee, Jin-Seok;Kim, Chang-Yup;Kim, Yong-Ik;Ha, Beom-Man
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.219-227
    • /
    • 2001
  • Objectives : To understand the current status of the opening, closing and relocation of primary medical institutes in Korea and identify the underlying decision factors. Methods : Sources of analyzed data included the medical institutional master file at the National Health Insurance Corporation(1998, 2000) and Regional Statistic Annual Bulletins. To investigate changes including the opening, closing and relocation, a total of primary medicalinstitutions(16,757 in 1998, 19,267 in 2000) were analysed. Results : Between 1998 and 2000, there was a 15.0%(2,510) increase in the number of primary medical institutions and the rate of increase in the rural area was higher than the urban area, and higher for specialty clinics than primary practice. However, these findings did not suggestany improvement in the maldistribution of primary medical institutions. During the time period studied, newly opened and closed primary medical institutions numbered 4,085 and 1,573, respectively. Additionally, institutions thatrelocated numbered 2,729, or 16.3% of all primary medical institutions in operation in 1998. These openings and closings were more frequent among young doctors. As a result of our analysis on the underlying regional factors forrelocation, the factors that were statistically significant were local per capita tax burden and the number of schools per ten thousand persons. !n, the case of institutional factors, movements were significantly associated with gender and the location of primary medical institutions. Conclusions : In order to establish effective long-term intervention for primary medical institutions, further study and monitoring of primary medical institutions and the identification of factors influencing opening location and relocation is necessary.

  • PDF

The Interface Scheme and Application Between Rolling Stock System and PSD (철도차량시스템과 PSD간 인터페이스 방안 및 적용 현황)

  • Lee Jong-Seong;Min Young-Ki;Kim Kyoung-Shik;Choi Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1510-1512
    • /
    • 2004
  • Platform Screen Door System is a facility on platform to separate platform from track, having automatic sliding door structures interlocked to opening and closing of train door with integrated control unit. When a train comes to a stop at a designed position at a station, onboard ATC/ATO system transmits train berth signal to wayside signaling system. In case of automatic/driverless operation, opening and closing of the Platform Screen Door will be controlled by wayside signaling system. Unfortunately, we often see the case in news that passengers fall into track and their contact with train lead to critical accidents. However, passengers will be free from such accidents on the platform with the Platform Screen Door System. Especially during the rush hours, to ensure passenger's safety and smooth getting on & off, it is necessary to arrange. some station staffs on the platform without the Platform Screen Door System. On the other hand, the Platform Screen Door System will realize such operation by fewer staffs. Due to the above reasons, the Platform Screen Door System is becoming more popular in subway system recently.

  • PDF

Extraction of Characteristics of Concrete Surface Cracks

  • Ahn, Sang-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.126-130
    • /
    • 2007
  • This paper proposes a method that automatically extracts characteristics of cracks such as length, thickness and direction, etc., from a concrete surface image with image processing techniques. This paper, first, uses the closing morphologic operation to adjust the effect of light extending over the whole concrete surface image. After applying the high-pass filtering operation to sharpen boundaries of cracks, we classify intensity values of the image into 8 groups and remove intensity values belong to the highest frequency group among them for the removal of background. Then, we binarize the preprocessed image. The auxiliary lines used to measure cracks of concrete surface are removed from the binarized image with position information extracted by the histogram operation. Then, cracks broken by the removal of background are extended to reconstruct an original crack with the $5{\times}5$ masking operation. We remove unnecessary information by applying three types of noise removal operations successively and extracts areas of cracks from the binarized image. At last, the opening morphologic operation is applied to compensate extracted cracks and characteristics of cracks are measured on the compensated ones. Experiments using real images of concrete surface showed that the proposed method extracts cracks well and precisely measures characteristics of cracks.

Small Target Detection using Morphology and Gaussian Distance Function in Infrared Images (적외선 영상에서 모폴로지와 가우시안 거리함수를 이용한 소형표적 검출)

  • Park, Jun-Jae;Ahn, Sang-Ho;Kim, Jong-Ho;Kim, Sang-Kyoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.4
    • /
    • pp.61-70
    • /
    • 2012
  • We propose a method that finds candidate targets based on morphology and detects a small target from them using modified gaussian distance function. The existing small target detection methods use predictive filters or morphology. The methods using predictive filters take long to approach least errors. The methods using morphology are weak at clutters and need to consider size of a small target when selecting size of structure elements. We propose a robust method for small target detection to complete the existing methods. First, the proposed method deletes clutters using a median filter. Next, it does closing and opening operation using various size of structure elements, and figures target candidate pixels with subtraction operation between the results of closing and opening operation. It detects an exact small target using a gaussian distance function from the candidates target areas. The proposed method is less sensitive to clutters, and shows a detection rate of 98%.

EFFICIENT IMPLEMENTATION OF GRAYSCALE MORPHOLOGICAL OPERATORS (형태학 필터의 효과적 구현 방안에 관한 연구)

  • 고성제;이경훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1861-1871
    • /
    • 1994
  • This paper presents efficient real time software implementation methods for the grayscale morphological composite function processing (FP) system. The proposed method is based on a matrix representation of the composite FP system using a basis matrix composed of structuring elements. We propose a procedure to derive the basis matrix for composite FP systems with any grayscale structuring element (GSE). It is shown that composite FP operations including morphological opening and closing are more efficiently accomplished by a local matrix operation with the basis matrix rather than cascade operations, eliminating delays and requiring less memory storage. In the second part of this paper, a VLSI implementation architecture for grayscale morphological operators is presented. The proposed implementation architecture employs a bit-serial approach which allows grayscale morphological operations to be decomposed into bit-level binary operation unit for the p-bit grayscale singnal. It is shown that this realization is simple and modular structure and thus is suitable for VLSI implementation.

  • PDF

Roof Ventilation Structure for Single Span Greenhouses of Arch Shape (아치형 단동 온실의 지붕 환기 구조)

  • Nam, Sang-Woon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.267-270
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouse of arch shape. Investigation on the roof ventilation structure for those greenhouses was conducted. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing roof vent and having controlled side vent only. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the roof and side vent.

  • PDF

Effects of Variable Valve Timing Operation Modes on Engine Performance (가변 밸브개폐시기 기구 운전의 엔진 성능에의 영향)

  • 구준모;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.24-29
    • /
    • 2001
  • Adaptive valve timing control is one of the promising techniques to accomplish the optimized mixture formation and combustion depending on the load and speed, which is needed to meet the future challenges in reducing fuel consumption and exhaust emissions. The behavior and the effect of adaptive valve timing control system has been investigated by computer simulation, which simulates the gas dynamics in engines. Improved fuel economy can be achieved by reduction of pumping loss under low and mid load conditions. EIVC(Early Intake Valve Closing) strategy turns out to be superior to LIVC(Late Intake Valve Closing) strategy in reducing fuel consumption. Deterioration of combustion quality can be overcome by introducing LIVO(Late Intake Valve Opening) strategy, which increases turbulent intensity in cylinders. Furthermore, LIVO can reduce HC emission by decreasing the required amount of fuel to be injected during cold start.

  • PDF

Significance of Intraoperative BAEPs Monitoring during Microvascular Decompression Surgery (미세혈관 감압술중 뇌간청각유발전위 감시장치의 유용성)

  • Kim, Tae Joon;Ko, Yong;Kim, Young Soo;Oh, Seong Hoon;Kim, Kwang Myung;Kim, Nam Kyu;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.635-639
    • /
    • 2000
  • Objective : Surgery for the microvascular decompression is mostly concerned with injury to the cranial nerves or brain stem by cerebellar retraction. Intraopeartive brain stem auditory evoked potentials(BAEPs) has been continuously monitored on surgery to evaluate the extent of injury, recovery of the nerves and prognosis. Methods : Of the 161 cases of CP angle surgery from Feb. 1996 to Apr. 1998, 103 cases were monitored during operation. Thirty five patients who had undergone similar surgery were selected and evaluated ; 23 patients were monitored and 12 were not during surgery. If monitor showed more than 0.5 mSec delay of latency, surgeon was given a warning not to retract brain any more. If more than 1mSec delay, surgeon was informed to stop surgery and wait for the returning of evoked potentials. The level of amplitudes and delay of latencies during the initial stage of operation, opening the dura, insertion of teflon patches, and closing the dura and recovery were then compared. Resuls : Twenty patients were male and 15 were female. Their average age was 50.26 years. Mean amplitude during the initial stage of operation was $0.60{\pm}0.25mV$, at opening the dura $0.56{\pm}0.26$, after teflon patches insertion $0.49{\pm}0.20$, and after closure of dura $0.47{\pm}0.28mV$. Mean latency during the early stage of operation was $6.08{\pm}0.67mSec$, at opening of dura $6.38{\pm}0.55$, insertion of teflon $6.97{\pm}0.59$, and closing the dura $6.17{\pm}0.54$. There was statistical significance in the difference of amplitudes between each procedures, and in the difference of latencies. For the complete recovery of amplitude and latency, it usually took average 5.65 minutes(0-20 min). In monitored group, only one patient required more than 20 minutes to recover and suffered from hearing disturbance after surgery. Others were recovered within 10 minutes without complications. However, 4 out of 12 patients who were not monitored showed hearing disturbance, and 1 patient had temporary facial palsy and dizziness(p=0.000). Conclusion : The results indicate that continuous intraoperative monitoring of BAEPs during CP angle surgery is seen mandatory procedure to prevent operative complications.

  • PDF

The study for function and operation of the excitation equipment for short circuit generator (단락발전기 용 여자장치의 조작과 기능에 대한 고찰)

  • Kim, Sun-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.735-736
    • /
    • 2008
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, CLR, Back Up Breaker, Making Switch and Excitation Equipment etc. Gradually an allowable tolerance of the short circuit test voltage is become smaller by the standards for short circuit test. The excitation equipment of short circuit generator is very important for test voltage is adjusted by the excitation equipment. Especially the excitation equipment must be possessed character of exactitude, durability and inalterability because some times around 10,000 times opening and closing short circuit test is requested by clint, which must be done within one minute. The purpose of this study for function and operation of the excitation equipment which rated DC voltage is 1,000V, rated DC current is 300A, rated out put is 30kW and type is YNEX 97S-441/609, is to help operation of short circuit generator.

  • PDF