• Title/Summary/Keyword: open-ended probe

Search Result 28, Processing Time 0.022 seconds

Open-Ended Coaxial Probe with Protruding Inner Conductor (내심이 돌출된 개방단말 동축선 프로브)

  • Jung Ji-Hyun;Jo Yu-Sun;Kim Se-Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.26-32
    • /
    • 2005
  • Open-ended coaxial probe is used to measure complex permittivities of materials in a wide bandwidth. Complex permittivity measured by a conventional coaxial probe suffers from severe fluctuation due to instrumental uncertainty when the difference between reflection coeffcients of reference and measuring materials is small. In this paper, open-ended coaxial probe with protruding inner conductor is suggested to increase the difference between reflection coefficients of reference and measuring materials. Its validity is assured by FDTD simulation and actual measurement.

The Effect of Finite Flange of Open-Ended Coaxial Probe on the Converted Complex Permittivity of PCB Substrate (개방 단말 동축선 프로브의 유한한 접지판이 PCB 기판의 복소 유전율 환산에 미치는 영향)

  • Jung Ji-Hyun;Kim Young-Sik;Kim Se-Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.52-59
    • /
    • 2006
  • To construct its complex permittivity from the reflection coefficient of a thin film such as PCB substrate measured by open-ended coaxial probe, an integral equation is formulated using modal analysis and equivalent source. The accuracy of the conversion model based on the integral equation is confirmed in both cases of converted complex permittivities calculated from numerically computed and actually measured reflection coefficients. And the maximum valid frequency of open-ended coaxial probe is limited by the size of its flange.

FDTD Simulation on the Effect of Manufacturing Error of an Open-Ended Coaxial Probe for Measuring Complex Permittivity (복소유전율 측정용 개방단말 동축선 프로브 제작오차의 영향에 관한 FDTD 모의계산)

  • Shin, Hyun;Hyun, Seung-Yeup;Kim, Sang-Wook;Kim, Se-Yun
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.8
    • /
    • pp.19-26
    • /
    • 1999
  • umerical simulations are performed to estimate how strongly the manufacturing error of an open-ended coaxial probe affects its measured complex permittivity of a contacted medium. The reflection coefficients of several dielectric materials contacted with an open-ended coaxial probe are calculated by employing the FDTD method. And then those complex permittivities are reconstructed by applying the calculated reflection coefficients into a new imaginary transmission-line model, which reveals more physically meaningful than the conventional model. It is found that the reconstructed complex permittivities suffer from significant error in spite of a slight imperfection of open-ended coaxial probe.

  • PDF

Stability and Accuracy of the Conversion Model of Open-Ended Coaxial Probe (개방 단말 동축선 프로브의 환산모델에 대한 안정성과 정확성)

  • Kim Yee-Jung;Jo Yu-Sun;Kim Se-Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.33-39
    • /
    • 2005
  • Complex permittivities of material in a wide bandwidth are measured by using an open-ended coaxial probe. To obtain a confident complex permittivity profile, the accuracy of measured reflection coefficients and the stability of the conversion model should be guaranteed in advance. In this paper, the sensitivity of our conversion model is analyzed by employing two instruments with different uncertainties. And various factors effected on the accuracy of measured reflection coefficients are investigated in experiment.

Analysis of Wave Reflection from an Open-Ended Coaxial Probe Using the FDTD Method (FDTD 방법을 이용한 동축선로 끝단에서의 전파반사 분석)

  • 박기억;손병문;오이석;구연건
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.10
    • /
    • pp.7-12
    • /
    • 1998
  • The wave reflections from several types of open-ended coaxial probes contacted on the various materials have been analyzed precisely by using the finite-difference time-domain(FDTD) technique in this paper. Due to the coordinate transformation from three-dimension to two-dimension, the computation was performed very efficiently. It was found that the reflection from an open-ended coaxial probe reduces as frequency or diameter of a coaxial line increases. The reflections from multi-layered media were also analyzed by the FDTD method. This analysis technique was verified by comparison with measurements and theoretical computations.

  • PDF

Simple Technique for Measurement of Complex Permittivity and Detection of Small Permittivity Change Using Partially Open Cavity

  • Park, Sangbok;Chung, Young-Seek;Cheon, Changyul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.268-272
    • /
    • 2014
  • This letter presents a measurement methodology of the complex permittivity of liquid using a partially open cavity in narrow band. The partially open cavity (POC) can measure dielectric small changes caused by the temperature variation of the liquid inside the cavity as well. Using the resonance frequency and unloaded quality factor of the proposed POC, the complex permittivity is evaluated. The apertures on the walls of the cavity are designed to circulate the liquid inside to outside of the POC and located at the corner area of the cavity to minimize the disturbance of field distribution at the dominant mode. The results measured by the proposed POC were compared with those by the conventional open-ended probe and Cole-Cole equation. The POC showed better performance in measuring small dielectric constant changes than the open-ended probe.

Measurement of Electromagnetic Properties of Concrete for Nondestructive Testing (비파괴 시험을 위한 콘크리트의 전자기적 특성의 측정)

  • 임홍철;정성훈
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.115-123
    • /
    • 2000
  • Characterizing the electromagnetic properties of concrete is essential to the enhancement of accuracy and reliability in nondestructive testing of concrete structures using electromagnetic techniques. To establish a data base for the properties of concrete, a measurement technique has been developed and a set of data has been obtained for the frequency range of 1~6 GHz. As moisture content is one of major contributing factors to determine permittivity of dielectric material, moisture content is varied during the measurement. An application of a measurement system which consists of open-ended coaxial probe and automatic network analyzer to concrete and mortar specimens is studied. For this, calibration techniques, size of specimens, and number of measurements necessary to obtain reliable data are investigated. From the measured data, it is shown that moisture content plays an important role to determine the permittivity of specimens. As the moisture content increases. The permittivity of specimens show tendency to approach the permittivity of water.

Dielectric Properties of Fresh Ginseng Determined by an Open-Ended Coaxial Probe Technique (수삼의 마이크로파 유전특성)

  • Hong, Seok-In;Lee, Boo-Yong;Park, Dong-June;Oh, Seung-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.470-474
    • /
    • 1996
  • The dielectric properties, dielectric constant (${\varepsilon}‘$) and loss factor (${\varepsilon}’$), of skin and pulp of fresh ginseng were measured from $25^{\circ}C$ to $67^{\circ}C$ using an open-ended coaxial probe technique for 915 MHz and 2450 MHz. Pulp and skin had dielectric constant of $30{\sim}64$ and loss factor between 10 and 20, each variable having a respective frequency dependence typical of materials with high water content. Although the loss factor was nearly constant, the dielectric constant increased as moisture content increased. The dielectric constant of ginseng pulp increased as temperature increased (temperature ${\leq}56^{\circ}C$), but any significant differences were not found in skin dielectric properties. Penetration depth for fresh ginseng were about 2 cm at 91.5 MHz and 1cm at 2450 MHz.

  • PDF

Comparison of the Measured Electrical Properties of Pig Internal Organs with the Given Values for Human Organs

  • Jung, Ji-Hyun;Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.161-165
    • /
    • 2012
  • The electrical properties of pig internal organs including lung, liver, heart, kidney, blood, stomach, and small intestine are measured using an open-ended coaxial probe and an improved virtual transmission-line model. The measured complex permittivities of the pig organs are compared with the given values of the corresponding human organs. A similarity between these values is confirmed. For organs such as lung, liver, heart, and kidney that have regular texture and contents, the complex permittivities are almost identical to those of the corresponding human organs. The complex permittivities of human and pig blood are also very close in value. However, relatively large deviations are observed for the cases of stomach and small intestine because the internal contents of these organs significantly affect the measured electrical properties.

Measurements of dielectric constants of soil to develop a landslide prediction system

  • Rhim, Hong Chul
    • Smart Structures and Systems
    • /
    • v.7 no.4
    • /
    • pp.319-328
    • /
    • 2011
  • In this study, the measurements of the dielectric constants of soil at 900 MHz and 1 GHz were made to relate those properties to the moisture content of the soil. This study's intention was to use the relationship between the dielectric constant and the moisture content to develop a landslide prediction system. By monitoring the change of the moisture content within the soil using ground penetrating radar (GPR) systems in the field, the possibility of a landslide is expected to be detected. To establish a database for the dielectric constants and the moisture content, the measurements of soil samples were made using both an open-ended dielectric coaxial probe and the GPR. Based on the measurement results, correlations between the GPR and reflector for each frequency at 900 MHz and 1 GHz were found for the dielectric constants and the moisture content. Finally, the mechanism of the measurement device to be implemented in the field is suggested.