• Title/Summary/Keyword: open technique

Search Result 1,380, Processing Time 0.04 seconds

Analysis of Formal Aesthetics of Fashion Designer's Works -Focused on Madeleine Vionnet & Christian Dior- (패션디자인 작품에 나타난 형태미 분석 -비요네와 디올의 작품을 중심으로-)

  • Yun, Ji-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1582-1594
    • /
    • 2005
  • The purpose of this study is to rediscover the value of form in fashion design by developing a new perspective of design appreciation. By examining and modifying the theories of Wolfflin and Belong, this paper tries to of for a new perspective for analyzing the characteristics of form in fashion designers' works. The three new perspective, Flat & Rounded, Closed & Opened and Part & Whole, can be used to analyze the formative aesthetic character of Vionnet's and Dior's works. Ten of Vionnet's and eleven of Dior's representative works selected and applied Delong's visual priority diagram to analyze their character. Vionnet and Dior, emphasized form and construction in their design and applied geometric shapes in their works. The main differences between Vionnet and Dior is that Vionnet's work transforms from geometric shapes in 2-dimentional space to drapery shapes in 3-dimensional space, Dior's work displays geometric shapes in 3-dimensional space. Vionnet created new formative art through the relationship between the clothes and human body. Vionnet's work has distinctively different qualities depending on whether the space is 2-dimensional or 3-dimensional showing transposition of form. In 2-dimensional space, Vionnet's works consist of triangles, rectangles and circles which are 'flat' and 'closed' in quality. These transform to solid forms by draping bias fabrics, which have a 'rounded' and 'open' quality. Dior tended to show artificial form rather than the natural lines of the body which is very different with Vionnet. Dior created clothes by using solid geometric form such as spheres, prisms, cylinders, pyramids and cubes in 3-dimensional space, which were visualized through constructive technique such as dart manipulation, boning, gathering, tucking, pleating, shirring and layering. Dior's works have their own form which does not relate with body shape. So his Works have a 'rounded' and 'closed' quality.

Subbrow Approach as a Minimally Invasive Reduction Technique in the Management of Frontal Sinus Fractures

  • Lee, Yewon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.679-685
    • /
    • 2014
  • Background Frontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are still controversial. In this article, we suggest a simple reduction method using a subbrow incision as a treatment for isolated anterior sinus fractures. Methods Between March 2011 and March 2014, 13 patients with isolated frontal sinus fractures were treated by open reduction and internal fixation through a subbrow incision. The subbrow incision line was designed to be precisely at the lower margin of the brow in order to obtain an inconspicuous scar. A periosteal incision was made at 3 mm above the superior orbital rim. The fracture site of the frontal bone was reduced, and bone fixation was performed using an absorbable plate and screws. Results Contour deformities were completely restored in all patients, and all patients were satisfied with the results. Scars were barely visible in the long-term follow-up. No complications related to the procedure, such as infection, uncontrolled sinus bleeding, hematoma, paresthesia, mucocele, or posterior wall and brain injury were observed. Conclusions The subbrow approach allowed for an accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by providing a direct visualization of the fracture. Considering the surgical success of the reduction and the rigid fixation, patient satisfaction, and aesthetic problems, this transcutaneous approach through a subbrow incision is concluded to be superior to the other reduction techniques used in the case of an anterior table frontal sinus fracture.

The Effect of Additives in the Cardioplegic Solution on the Recovery of Myocardium, Compariosn Among Albumin, Mannitol, and Glucose (심마비용액의 삼투압을 유지하기위한 첨가 물질들의 차이가 심근보호에 미치는 영향)

  • Kim, Eun-Gi;Lee, Jong-Guk;Lee, Sang-Heon
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1058-1067
    • /
    • 1991
  • High potassium cardioplegia is a widely accepted procedure to enhance myocardial protection from ischemic injuries associated with open heart surgery. Maintaining optimum osmolarity of the cardioplegic solution is one of the required conditions for an ideal cardioplegic solution Albumin is an frequently added component for maintaining optimum osmolarity of clinically used cardioplegic solutions. But the source of albumin is human blood so that the supply is limited and the cost of manufacturing is relatively high. Recently there are moves to minimized the use of blood product for fear of blood-associated infections or immunological disorders. In this experiment, we substituted mannitol or glucose for albumin added to the cardioplegic solution which has been used at the Wonju Medical College, To determine whether addition of mannitol or glucose instead of albumin in the cardioplegic solution can produce satisfactory myocardial protection during ischemia, three different groups of isolated rat heart perfused by modified Langendorff technique were studied. Wonju Cardioplegic Solution was selected as a standard high potassium[18mEq/L of K+] cardioplegic solution. Three kinds of cardioplegic solution were made by modifying the composition maintaining the same osmolarity[339$\pm$1mOsm/Kg] Isolated rat heart were perfused initially with retrograde nonworking mode and then changed to working mode. After measuring the heart rate, systolic aortic pressure, aortic flow, coronary flow, ischemic arrest by aorta cross clamp and cardioplegia was made maintaining the temperature of water jacket at 10oC. The heart was rewarmed and reperfused after 60min of ischemic arrest with intermittent cardioplegia at the 30min interval. The time to return of heart beat and the time required to get. Regular heart beat were observed after reperfusion. The recovery rate of the functional variables-heart rate, systolic aortic pressure, aortic flow, coronary flow and cardiac output were calculated and compared among the three groups of different cardioplegia-albumin, mannitol, and glucose. The wet weight and dry weight was measured and the water content of the heart as figured out for comparison. The time to return of heart beat was fastest in the albumin group, The functional recovery rates were best in the albumin group also. In the above conditions, albumin was the best additive to the cardioplegic solution compared to the mannitol or glucose.

  • PDF

Arthroscopic Reconstrucion in Megafrequency of Recurrent Anterior Shoulder Dislocations (관절경을 이용한 고 빈도 재발성 전방 견관절 탈구의 재건술)

  • Ko, Sang-Hun;You, Chong-Il;Cho, Sung-Do;Choi, Chang-Hyuk;Cheon, In-Ho;Woo, Jong-Keun;Kwag, Chang-Yul;Yun, Dong-Jin;Choe, Seong-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.194-200
    • /
    • 2005
  • Purpose: To evaluate the short-term follow up outcome and the effectiveness of arthroscopic vertical shift of anteroinferior capsulolabral complex, plication of AIGHLC (anterior band of inferior glenohumeral ligament complex) and thermal capulorraphy, posteroinferior suture plication, rotator interval closure as an adjuncts in recurrent instability of megafrequency with night time dislocation. Materials & Methods: From March 1998 to February 2004, we have had 18 shoulders out of 156. All of the cases have been night time dislocation above more one time. The age were average 29.4$(21{\sim}37)$ year old. The average follow up were 21.1 $(12{\sim}45)$months We checked Rowe score and ROM at pre-operation, post-operation 6 months,1 year & last follow up period. Results: Above good results were 16 cases(88.9%). The excellent were 6 cases, good were 10, fair 1, poor 1. Conclusions: In recurrent anterior shoulder dislocation in greater than 50 frequency, arthroscopic stabilization can be an alternative technique for selected patients against open inferior capsular shift. But more long ter n follow up and large materials will be needed in the future study.

  • PDF

Efficacy of Temporal Fixation Using Threaded Trans-Calcaneal Pin in Patients with Ankle Fracture-Dislocation or Tibia Pilon Fractures (발목 골절 및 탈구 혹은 경골 천정 골절 환자들의 수술에 있어 경종골핀을 이용한 발목 외고정 장치를 적용했을 때의 임상적 효용성)

  • Park, Dae-Hyun;Gwak, Heui-Chul;Kim, Jung-Han;Lee, Chang-Rak;Kwon, Yong-Uk;Choo, Hye-Jung;Park, Chul-Soon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2020
  • Purpose: Ankle fractures with dislocations and pilon fractures at the distal tibia are usually associated with soft tissue damage caused by high-energy damage. Recently, a two-stage operation to perform internal fixation after the application of external fixation devices for stabilizing soft tissues has been accepted as the treatment of choice. This paper reports the clinical result of these injuries treated with threaded trans-calcaneal pin external fixation devices. Materials and Methods: Thirty-three patients diagnosed with ankle fractures with dislocations or tibial pilon fractures without open wounds. They underwent surgical treatment with threaded trans-calcaneal pin external fixation from January 2008 to February were enrolled in this study. This study evaluated the visual analogue scale (VAS), foot function index (FFI), and Olerud & Molander score as well as whether complications occurred. Results: The average VAS showed a meaningful decrease (p<0.001) from 7.4 before surgery to 2.6 after application of the external fixation device, and 1.4 at 12 months after surgery. The FFI also decreased significantly from 84.3 preoperatively to 20.3 at 12 months postoperatively (p<0.001). The Olerud & Molander score averaged 71.4 points, showing good clinical results. Complete bone union was observed in all patients. One patient each underwent debridement due to wound necrosis and infection in the pin insertion site. At the final follow-up, seven patients had posttraumatic ankle joint arthritis, according to a radiological examination. Conclusion: Manual reduction and external fixation using a threaded trans-calcaneal pin is a suitable surgical technique that is easy to perform and shows good clinical outcomes in stabilizing soft tissue damage in fractures and dislocations of ankle fracture or tibia pilon fractures in foot and ankle injury.

A Technique to Recommend Appropriate Developers for Reported Bugs Based on Term Similarity and Bug Resolution History (개발자 별 버그 해결 유형을 고려한 자동적 개발자 추천 접근법)

  • Park, Seong Hun;Kim, Jung Il;Lee, Eun Joo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.12
    • /
    • pp.511-522
    • /
    • 2014
  • During the development of the software, a variety of bugs are reported. Several bug tracking systems, such as, Bugzilla, MantisBT, Trac, JIRA, are used to deal with reported bug information in many open source development projects. Bug reports in bug tracking system would be triaged to manage bugs and determine developer who is responsible for resolving the bug report. As the size of the software is increasingly growing and bug reports tend to be duplicated, bug triage becomes more and more complex and difficult. In this paper, we present an approach to assign bug reports to appropriate developers, which is a main part of bug triage task. At first, words which have been included the resolved bug reports are classified according to each developer. Second, words in newly bug reports are selected. After first and second steps, vectors whose items are the selected words are generated. At the third step, TF-IDF(Term frequency - Inverse document frequency) of the each selected words are computed, which is the weight value of each vector item. Finally, the developers are recommended based on the similarity between the developer's word vector and the vector of new bug report. We conducted an experiment on Eclipse JDT and CDT project to show the applicability of the proposed approach. We also compared the proposed approach with an existing study which is based on machine learning. The experimental results show that the proposed approach is superior to existing method.

An Analysis of the Effectiveness of Social Path Using the Space Syntax Technique (Space syntax 기법을 활용한 Social Path 효과분석)

  • Choi, Sung Taek;Lee, Hyang Sook;Choo, Sang Ho;Jang, Jin Young;Kim, Su Jae
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.2
    • /
    • pp.192-203
    • /
    • 2015
  • Pedestrians not only walk along pedestrian pathways, but also choose unusual routes such as passing through buildings or crossing large scale open spaces. This study defines these unusual paths as social path, and includes them into one of the pedestrian road categories. Previous pedestrian accessibility and route choice studies could not evaluate correctly the space connectivity or optimal route because the social path was not considered properly. Therefore, this study analyzes the effectiveness of the social path in view of space connectivity focused on Coex and Seoul stations in Seoul, which are representative transit oriented development(TOD) areas. Global integration, which is widely used in network analysis, is selected (as performance index) to identify the space hierarchy and define new pedestrian links. The study results show that the network connectivity is improved especially in the main streets and social paths. This study demonstrated that the social path should be considered in finding the pedestrian optimal route from the practical perspective.

Aesthetic Rhinoplasty for the Improvement of the Lateral Facial Profile; Image-up Rhinoplasty (얼굴의 측면 윤곽선 개선을 위한 미용 코성형술)

  • Min Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.205-213
    • /
    • 2005
  • There are several characteristics of the nose of orientals. The dorsum of nose is flat and low, the skin is thick with severe tension, the nasal tip is bulbous, the nostril is wide, and the projection of the nose is limited due to a poorly developed alar cartilage with a short columella. In order to improve these untoward characteristics of the nose of Orientals aesthetically, plain augmentation of the dorsum and tip-plasty with conventional methods has been performed by many plastic surgeons. However these conventional rhinoplasty is not enough to obtain satisfactory results when transforming into a more beautiful and aesthetically charming appearance. In order to produce the optimal nasal shape and profile, it is extremely important to consider the aesthetic surgical factors, which are; the position of the nasion, the optimal nasolabial angle(95-100 degree in Orientals), the natural exposure of infra-tip lobule with and columella, the position of the tip defining point in harmony with the dorsal profile and the smooth and natural silhouette of the lateral nasal profile as it descends into the inferior portion of the nose. From April, 2003 to August, 2004, a total of 52 patients underwent open rhinoplasty, adhering to the strict aesthetic principles considered and described priorly. Surgical approach was done through a transcolumella incision and an alar rim incision. The nasal dorsum was augmented with a silicone implant and the shape of the columella and the nasolabial angle were finessed with a silicone strut implant which was placed in between the medial crurae in a manner of a non-visible graft. The nasal tip was corrected by alar cartilage suture technique and onlay graft of shield shaped Alloderm and Gore-Tex. Author obtained the optimal nasal shape and profile aesthetically, and the results, considered satisfactory in all patients without any complications, are as follows; 1. the average increase in nasal length was 2.5 mm, 2. the average decrease in nasal width was 2.1 mm, 3. the average increase in nasal tip projection was 3.2 mm, 4. the changes of nasolabial angles were from 85.5 degree to 94.7 degree, 5. the changes of the angle between the long axis of the external naris was from 101.3 degree to 89.5 degree. In conclusion, this surgical procedure is an effective, reliable and a valuable method in improving the nasal shape, tip projection, nasolabial angle and especially, the lateral facial profile of Orientals aesthetically.

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

In Situ Monitoring of the MBE Growth of AlSb by Spectroscopic Ellipsometry

  • Kim, Jun-Yeong;Yun, Jae-Jin;Lee, Eun-Hye;Bae, Min-Hwan;Song, Jin-Dong;Kim, Yeong-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.342-343
    • /
    • 2013
  • AlSb is a promising material for optical devices, particularly for high-frequency and nonlinear-optical applications. And AlSb offers significant potential for devices such as quantum-well lasers, laser diodes, and heterojunction bipolar transistors. In this work we study molecular beam epitaxy (MBE) growth of an unstrained AISb film on a GaAs substrate and identify the real-time monitoring capabilities of in situ spectroscopic ellipsometry (SE). The samples were fabricated on semi-insulating (0 0 1) GaAs substrates using MBE system. A rotating sample stage ensured uniform film growth. The substrate was first heated to $620^{\circ}C$ under As2 to remove surface oxides. A GaAs buffer layer approximately 200 nm- thick was then grown at $580^{\circ}C$. During the temperature changing process from $580^{\circ}C$ to $530^{\circ}C$, As2 flux is maintained with the shutter for Ga being closed and the reflection high-energy electron diffraction (RHEED) pattern remaining at ($2{\times}4$). Upon reaching the preset temperature of $530^{\circ}C$, As shutter was promptly closed with Sb shutter open, resulting in the change of RHEED pattern from ($2{\times}4$) to ($1{\times}3$). This was followed by the growth of AlSb while using a rotating-compensator SE with a charge-coupled-device (CCD) detector to obtain real-time SE spectra from 0.74 to 6.48 eV. Fig. 1 shows the real time measured SE spectra of AlSb on GaAs in growth process. In the Fig. 1 (a), a change of ellipsometric parameter ${\Delta}$ is observed. The ${\Delta}$ is the parameter which contains thickness information of the sample, and it changes in a periodic from 0 to 180o with growth. The significant change of ${\Delta}$ at~0.4 min means that the growth of AlSb on GaAs has been started. Fig. 1b shows the changes of dielectric function with time over the range 0.74~6.48 eV. These changes mean phase transition from pseudodielectric function of GaAs to AlSb at~0.44 min. Fig. 2 shows the observed RHEED patterns in the growth process. The observed RHEED pattern of GaAs is ($2{\times}4$), and the pattern changes into ($1{\times}3$) with starting the growth of AlSb. This means that the RHEED pattern is in agreement with the result of SE measurements. These data show the importance and sensitivity of SE for real-time monitoring for materials growth by MBE. We performed the real-time monitoring of AlSb growth by using SE measurements, and it is good agreement with the results of RHEED pattern. This fact proves the importance and the sensitivity of SE technique for the real-time monitoring of film growth by using ellipsometry. We believe that these results will be useful in a number of contexts including more accurate optical properties for high speed device engineering.

  • PDF