• Title/Summary/Keyword: open fracture

Search Result 634, Processing Time 0.021 seconds

Two Part Triplane Fracture with Extention through Medial Malleolus (Four Cases Report) (족관절 내과를 침범한 두 부분 삼면 골절(4예 보고))

  • Cha, Seung-Do;Kim, Hyung-Soo;Chung, Soo-Tae;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Kim, Yong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • The triplane fracture has been described as a fracture of the distal tibial epiphysis occurring across three planes-sagittal, transverse and coronal. The characteristic pattern of fusion of distal tibial epiphysis explains the special configuration of the fragments in the triplane fracture. According to Dias-Tachdjian classification, triplane fracture is classified two part fracture, three part fracture, four part fracture and two part fracture with extension to the medial malleolus. Among four types, two part triplane fracture with extension to the medial malleolus is a relatively rare injury and generally is not treated by closed reduction. Such fractures should have an anatomic reduction and adequate fixation to restore the joint congruity and obtain an anatomic reduction of the growth plate to prevent a future growth deformity. This is usually best accomplished with an open reduction and screw fixation or k-wire fixation. We experienced two part triplane fracture with extension to medial malleolus and check the CT to define the extent of the injury completely. And then we underwent open reduction and screw fixation for the fracture. As a result, we present four cases of two part triplane fracture with extension with review of related literatures.

  • PDF

The Communited Fracture of Larynx (후두 분쇄 골절의 치료)

  • 김형태;조승호;김민식;선동일;최재혁
    • Korean Journal of Bronchoesophagology
    • /
    • v.3 no.1
    • /
    • pp.174-180
    • /
    • 1997
  • Acute laryngeal trauma is a rare injury, but it threatens both the quality and maintenance of life. The optimal goal of treatment for acute communited laryngeal fracture is restoration of the skeletal framework and epithelial lining of endolarynx. But though the diagnostic skill has been developed, decision making for treatment of laryngeal trauma such as operating tim, open exploration versus closed reduction and stenting is very difficult and controversial. Recently, the authors experienced two cases with severe communited fractures of laryngeal framework and endolaryngeal avulsion injuries who were treated successfully with open surgical repair without stenting. So we report these two cases with review of the literatures.

  • PDF

Usefulness of indirect open reduction via a transconjunctival approach for the treatment of nasal bone fracture associated with orbital blowout fracture

  • Kim, Tae Ho;Kang, Seok Joo;Jeon, Seong Pin;Yun, Ji Young;Sun, Hook
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.102-107
    • /
    • 2018
  • Background: Nasal fracture and orbital blowout fracture often occur concurrently in cases of midface blunt trauma. Generally, these multiple fractures treatment is surgery, and typically, the nasal bone and orbit are operated on separately. However, we have found that utilizing a transconjunctival approach in patients with concurrent nasal bone fracture and orbital blowout fracture is a useful method. Methods: The participants in the present study included 33 patients who visited the Plastic Surgery outpatient department between March 2014 and March 2017 and underwent surgery for nasal fracture and orbital blowout fracture. We assessed patients' and doctors' satisfaction with surgical outcomes after indirect open reduction via a transconjunctival approach for the treatment of nasal bone fracture with associated orbital blowout fracture. Results: According to the satisfaction scores, both patients and doctors were satisfied with transconjunctival approach. Conclusion: We presented here that our method enables simultaneous operation of nasal fracture accompanied by orbital blowout fracture, rather than treating the two fractures separately, and it allows precise reduction of the nasal fracture by direct visualization of the fracture site without any additional incisions or difficult surgical techniques. Also, by preventing the use of excessive force during reduction, this method can minimize damage to the nasal mucosa, thereby reducing the incidence of nasal bleeding.

A Clinical Study of Mandibular Angle Fracture

  • Yoon, Wook-Jae;Kim, Su-Gwan;Oh, Ji-Su;You, Jae-Seek;Lim, Kyung-Seop;Shin, Seung-Min;Kim, Cheol-Man
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.5
    • /
    • pp.201-206
    • /
    • 2014
  • Purpose: To establish management protocol for mandibular angle fracture, we describe pertinent factors including cause, impacted third molar and recent treatment tendency. Methods: We examined the records of 62 patients who had unilateral mandibular angle fracture. Sixty patients who had open reduction surgery were examined at postoperative weeks 1, 4, 8, 12, and 28. Results: Left mandibular angle fracture is frequent in younger males. Presence of the mandibular third molar can increase fracture risk. Because of attached muscle, favorable fractures occurred primarily in the mandibular angle area. Conclusion: Extracting the mandibular third molar can prevent angle fractures, and open reduction with only one plate adaptation is generally the proper treatment method for mandibular angle fracture.

Open Reduction and Internal Fixation (ORIF) of Trapdoor Orbital Floor Blowout Fracture with Absorbable Mesh Plate (뚜껑문 안와저 골절에 있어서 망상 흡수성 판을 이용한 관혈적 정복술 및 내고정술)

  • Kwon, Yu-Jin;Kim, Ji-Hoon;Hwang, Jae-Ha;Kim, Kwang-Seog;Lee, Sam-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.619-625
    • /
    • 2010
  • Purpose: Trapdoor orbital blowout fracture is most common in orbital blowout fracture. Various materials have been used to reconstruct orbital floor blowout fracture. Absorbable alloplastic implants are needed because of disadvantages of nonabsorbable alloplastic materials and donor morbidity of autogenous tissue. The aim of the study is to evaluate usefulness of absorbable mesh plate as a reconstructive material for orbital blowout fractures. Methods: From December 2008 to October 2009, 18 trapdoor orbital floor blowout fracture patients were treated using elevator fixation, depressor fixation, or elevatordepressor fixation techniques with absorbable mesh plates and screw, depending on degree of orbital floor reduction, because absorbable mesh plates are less rigid than titanium plates and other artificial substitutes. Results: Among 18 patients, 5 elevator fixation, 4 depressor fixation, and 9 elevator and depressor fixation technique were performed. In all patients, postoperative computed tomographic (CT) scan showed complete reduction of orbital contents and orbital floor, and no displacement of bony fragment and mesh plate. Mean follow-up was 10 months. There were no significant intraoperative or postoperative complications. Conclusion: Three different techniques depending on the degree of orbital floor reduction are useful for open reduction and internal fixation of trapdoor orbital floor blowout fracture with absorbable mesh plates.

STRESS ANALYSIS OF A HUMAN MANDIBLE UNDER VARIOUS LOADS USING FINITE ELEMENT METHOD (하악골의 부위별 충격시 발생되는 응력에 대한 유한 요소법적 연구)

  • Kim Sung-Rae;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.7-22
    • /
    • 1992
  • The stress distributions on a human mandible for 18 load cases under two different boundary conditions (mouth open and closed), using the three dimensional finite element modeling were studied. Also, the expected fracture loads for each load cases were calculated by using the Von-Mises yield criterion. The model of a mandible with all teeth was composed of 2402 hexahedron elements and 3698 nodes. CAD techniques were used to analyze the 3-dimensional results. The conclusions of this study were as follows: 1. In the mouth open state, the maximum stress occured at the condyle neck; when the lateral load was exerted, the maximum stress occured at the load side condyle. 2. In the mouth closed state, when the loads were exerted on the mandibular body and chin, the maximum stress occured at the loaded area, and when the loads were exerted on the angle and ramus, the maximum stress occured at the condyle neck. 3. The expected fracture loads in each load case were calculated using the Von-Mises yield criterion, and it was confirmed that the mandible in the mouth open state was more easily fractured than that in the mouth closed state, and the expected fracture loads are lesser in the cases that load direction is parallel at mandibular plane than 45°. 4. The magnitudes of the expected fracture loads increased in the order of angle, ramus, body and chin in case of the mouth closed state, while chin, body, angle and ramus in case of the mouth open state. 5. The Von-Mises stress concentration regions analyzed by F.E.M. corresponded well with the results of clinical studies.

  • PDF

ANALYSIS OF $PGE_2$ CONCENTRATION IN SYNOVIAL FLUID ASPIRATES FROM TMJS OF PATIENTS WITH MANDIBULAR FRACTURE (하악골절 환자에서 악관절강내 활액의 $PGE_2$ 농도 분석)

  • Lee, Gi-Hyug;Kim, Su-Gwan;Kim, Myung-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.204-208
    • /
    • 2001
  • The purpose of this study is to examine the change of enzymeimmuno-assay for $prostaglandinE_2$ in the synovial fluid lavage specimen of patients with mandibular fracture patients without condylar fracture. For this study, fourteen patients (eight males, six females) with mandibular fractures without condylar fracture was investigated to analyse the synovial fluid from upper temporomandibular joint cavities. Synovial fluid was collected from TMJ cavities of mandibular fracture patients before open reduction and after one week of open reduction, and then stored in liquid nitrogen tank after centrifuge. Two synovial fluid lavage samples of TMJs of 2 asymptomatic served as normal controls referred from other data. The concentrations of $PGE_2$ were measured by use of $PGE_2$ EIA System ($Amersham^{(R)}$). The following results were obtained: 1) In nine patients, the concentrations of $PGE_2$ are lower after open reduction than before. 2) In three patients, the concentrations of $PGE_2$ are higher after open reduction than before. 3) There was no statistical significant between the preoperative group and postoperative 7 days (p>0.05), but there was some difference between the two groups. In conclusion, the results suggest that $PGE_2$ probably does not play as important role in the harm of TMJ.

  • PDF

Treatment of a naso-orbito-ethmoid fracture using open reduction and suspension sutures: a case report

  • Youngsu, Na;Chaneol, Seo;Yongseok, Kwon;Jeenam, Kim;Hyungon, Choi;Donghyeok, Shin;Myungchul, Lee
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.6
    • /
    • pp.269-273
    • /
    • 2022
  • Naso-orbito-ethmoidal (NOE) fractures are complicated fractures of the mid-face. The treatment of NOE fractures is challenging and a comprehensive treatment strategy is required. We introduce a case of NOE fracture treated with open reduction and suspension sutures. A 28-year-old woman presented with a unilateral NOE fracture. To reduce the frontal process of the maxilla, a suspension suture was made by pulling the fragment using a double arm suture via a transcaruncular incision. The suture thread was placed in the horizontal plane. Another suspension suture on the inferior orbital rim assisted reduction procedure, and they passed through the overlying skin. The reduction alignment could be finely adjusted by tightening the transcutaneous suture threads while checking the degree of bone alignment through the subciliary incision. The two suture threads were suspended using a thermoplastic nasal splint. An additional skin incision on the medial canthal area, which would have resulted in a scar, could be avoided. Four months postoperatively, computed tomography showed an accurate and stable reduction. The patient was satisfied with her aesthetic appearance, and functional deficits were not present.

Surgical Treatment of Distal Tibia Fractures (원위 경골 골절의 수술적 치료)

  • Jeong, Jae-Jung;Kang, Do-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.174-181
    • /
    • 2013
  • Distal tibia fractures were mainly caused by high energy trauma and the lower legs were enveloped in poor soft tissue. Therefore, there are many open fractures and concomitant soft tissue injuries in distal tibia fractures. For the restoration of ankle function, the surgical treatment was performed in distal tibia fractures. However, it is difficult to treat the distal tibia fracture surgically. There are many complications in distal tibia fracture due to highly comminuted fracture and poor soft tissue condition. There are many surgical methods for distal tibia fractures, such as, external fixator, intramedulary nailling, open reduction & internal fixation, and minimally invasive plate osteosynthesis. We reviewed the surgical treatments of distal tibia fractures.

Stress Fracture in Medial Malleolus in Ankle (A Case Report) (족근관절 내과에 발생한 피로골절(1예보고))

  • Lee, Kyung-Tai;Young, Ki-Won;Park, Shin-Yi;Lee, Young-Koo;Na, Sang-Eun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.224-226
    • /
    • 2008
  • Although stress fracture of lower extremity is a relatively common, stress fracture of medial malleolus is rare. So we report one case. He is a 17 year old soccer player and successfully treated with surgical treatment (open reduction and internal fixation with one screw.

  • PDF