• Title/Summary/Keyword: opacity

Search Result 488, Processing Time 0.027 seconds

Clinical investigation of lipoid pneumonia in adults (성인에서 발생한 지방성 폐렴의 임상적 고찰)

  • Hyun, Jae Geun;Rhee, Chong H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.965-975
    • /
    • 1996
  • Background : Exogenous lipoid pneumonia is caused by inhalation or aspiration of animal, vegetable or mineral oil. Most cases are ascribed to aspiration of oil in laxatives or nose drops Petroleum, another pure hydrocarbon used as a base in various medications, is occasionally involved. Especially animal oil produces severe tissue inflammatory reaction, but most patients present with only abnormal chest X-ray and no specific clinical symptoms or signs. Method: Seven patients, 3 males and 4 females, with exogenous lipoid pneumonia, who was hospitalized or referred to pulmonary division at Samsung Medical Center from December 1994 10 July 1996, were included. They hadn a history of laking shark liver oil(so-called "squalene") for varying period of time. We reviewed clinical, radioloic and pathologic findings. Result: Patients look 7 to 30 capsules of "squalene" a day for at least one month to 5 years. Six cases had chronic disease such as diabetes, hypertension, or cerebrovascular accident. Respiratory symptoms of mild fever, cough and sputum were present in 3 cases and in 3 cases there was no clinical symptoms and signs but abnormal findings by chest X - ray. The major radiologic findings by simple chest X - ray and computed tomography consisted of consolidation, infiltration involving mainly right middle and both lower lobes, and ground-glass opacity. Five of six bronchoscopic examinations demonstrated both lipid droplets floating on the surface of bronchoalveolar lavage fluid and Lipid-laden macrophages in bronchoalveolar lavage fluid or lung tissue. Follow-up chest X -ray showed improvement in 4 cases but no marked interval change in 3 cases after removal of exposure to "squalene". Conclusion: Shark liver oil can induce lipoid pneumonia in adults. In case of high clinical suspicion, confirmation of "squalene" use by careful history taking is required and bronchoscopy is helpful in diagnosis.

  • PDF

Comparison of Clinical Characteristics of Pneumocystis Carinii Pneumonia Between HIV Infected and Non-infected Persons (인간 면역결핍 바이러스 감염자와 비감염자에서 발생한 주폐포자충 폐렴의 임상 양상 비교)

  • Choi, Jun Yong;Lee, Kkot Sil;Park, Yoon Soo;Cho, Cheong Ho;Han, Sang Hoon;Choi, Suk Hoon;Chin, Bum Sik;Park, Yoon Seon;Chang, Kyung Hee;Song, Young Goo;Kim, June Myung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.4
    • /
    • pp.370-377
    • /
    • 2003
  • Background : Pneumocystis carinii pneumonia (PCP) is one of the most common cause of infection in patients with HIV infection. Recently, the incidence of PCP have been increasing in immunocompromised hosts without HIV infection. We compared the clinical characteristics of PCP between HIV infected and non-infected persons. Patients and Methods : We retrospectively reviewed the charts of 25 patients diagnosed as PCP from 1996 to 2002. Age, sex, underlying conditions, use of immunosuppressants, clinical courses, laboratory findings, treatment and prognosis were compared between HIV infected and non-infected persons. Results : Twenty-five patients with PCP were identified. 16 were HIV infected, and 9 were HIV non-infected. The mean age of overall patients was $43.4{\pm}13.2$ years. Underlying conditions in HIV non-infected persons were hematologic malignancy (7 cases), solid organ transplant (1 case), and autoimmune disease (1 case). Seven cases (77.8%) of HIV non-infected persons had a history of steroid use. Mean duration of symptoms was longer in HIV infected persons than in HIV non-infected persons, but it was not statistically significant. PaO2 was lower in HIV infected persons ($61.2{\pm}16.9$ mmHg vs. $65.4{\pm}15.4$), but it was not statistically significant. Chest X ray showed typical ground glass opacity in 12 cases (75%) of HIV infected persons and in 4 cases (44.4%) of HIV non-infected persons. Twelve cases (75%) of HIV infected persons were treated with steroid, as were 6 cases (66.7%) of HIV non-infected persons. Ventilator care was needed in 6 cases (37.5%) of HIV infected persons and in 2 cases (22.2%) of HIV non-infected persons. Mortality of HIV infected persons was 50%, and that of HIV non-infected persons was 11.1%. Conclusions : PCP showed some different clinical characteristics between HIV infected and non-infected persons. Prospective studies regarding the risk factors of PCP, prophylaxis, treatment and prognosis in HIV infected and non-infected persons are warranted.

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease

  • Hye Jeon Hwang;Hyunjong Kim;Joon Beom Seo;Jong Chul Ye;Gyutaek Oh;Sang Min Lee;Ryoungwoo Jang;Jihye Yun;Namkug Kim;Hee Jun Park;Ho Yun Lee;Soon Ho Yoon;Kyung Eun Shin;Jae Wook Lee;Woocheol Kwon;Joo Sung Sun;Seulgi You;Myung Hee Chung;Bo Mi Gil;Jae-Kwang Lim;Youkyung Lee;Su Jin Hong;Yo Won Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.807-820
    • /
    • 2023
  • Objective: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software. Materials and Methods: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system. Results: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT. Conclusion: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.

A Case Study on the Processing of Siji(試紙) in the Mid-19th Century - Focusing on Lee Mangi's Sigwon(試卷) - (19세기 중반 시지(試紙)의 가공 사례 연구 - 이만기(李晩耆) 시권(試卷)을 중심으로 -)

  • CHUN Jiyoun;OH Joonsuk
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.3
    • /
    • pp.90-101
    • /
    • 2024
  • The test answer sheets submitted by examinees in the Joseon Dynasty were called Sigwon (test papers with answers, 試卷), and Siji (blank test papers, 試紙) were generally prepared by the examinees themselves. At that time, paper was not produced as a standard product, so there was no uniformity in size or manufacturing method. Mulberry paper in the Joseon Dynasty was basically transparent, so various paper processing methods were applied for examinees to write answers on both sides. In order for ink lines to be written smoothly, Dochim (hitting paper with a wooden bat on the stone, 搗砧) or surface processing was treated. We found a 19th-century Siji (試紙) that was processed in a unique way, which led to this study. An unusual Sigwon (試卷) is one by Lee Mangi (李晩耆) from 1848 owned by the National Folk Museum of Korea. We found that an opaque white substance was thickly applied between the papers of this Siji (試紙). Through component analysis using infrared spectrophotometry, fluorescence X-ray spectroscopy, optical and polarizing microscopy, and electron microscopy, this white substance was proved to be rice starch. From these analyses, it is presumed that this Siji (試紙) was made by soaking rice flour in water to remove a significant amount of protein, and then applying wet starch containing a small amount of protein between sheets of paper. In addition, with a Siji (試紙) reproduction experiment, we found that the paper reproduced by this processing method was thick and high in whiteness and opacity. This is believed to be a production method designed to produce double-sided paper without using multiple sheets of paper, which was difficult to obtain at that time. In this study, the material processed between the sheets of paper was disclosed only from < Lee Mangi (李晩耆)'s Sigwon (試卷)(Minsok 71745)>, but this appears to be one of several processing methods to treat the paper during the Joseon Dynasty. We hope that more similar Sigwons will be discovered in the future and that extensive research on processing methods will be conducted.

Productivity Evaluation of Rosemary Shoots using Artificial Light Sources in Multi-layer Cultivation (다단재배에서 인공광원을 이용한 로즈마리 어린순의 생산성 평가)

  • Myeong Suk Kim;Jung Seob Moon;Song Hee Ahn;Dong Chun Cheong;Min Sil Ahn;So Ra Choi
    • Journal of Bio-Environment Control
    • /
    • v.33 no.3
    • /
    • pp.163-171
    • /
    • 2024
  • This study was aimed to investigate the effects of layer-by-floor environmental conditions and lower shelf supplemental lighting on the productivity of fresh shoots when growing rosemary in multi-layer cultivation. The 10-cm cuttings from stock plants of common rosemary (Rosemarinus officinalis) were planted in a 128-hole tray, rooted, and then transplanted into pots of 750, 1,300, and 2,000 mL. Afterwards, they were placed on multi-layer shelves (width × length × height: 149 × 60 × 57 cm, 3-layer) in a two-linked greenhouse and cultivated using the sub-irrigation. The productivity of young shoots by layer of the multi-layer shelf was the highest on the third floor (top floor), but productivity decreased sharply after September due to stem lignification caused by excessive light during the summer. Conversely, the lower two layers exhibited faster growth rate of young shoots until the late cultivation period, but the quality decreased due to stem softening and leaf epinasty. To address the excessive light problem on the third floor during the summer, shading was implemented at 30% opacity in July and August, resulting in a 210% increase in rosemary young shoots count and a 162% increase in fresh weight per unit area compared to the unshaded control. To improve the lighting deficiency on the lower layer, supplemental lighting with LED at 30 W increased rosemary young shoot harvest by 168% from June to September compared to no supplemental lighting, but it decreased productivity after September. Therefore, when growing rosemary in multi-layer, it is judged that intensive production of young shoots is possible if the third floor (top layer) is shaded with 30% of light from July to August to prevent stem lignification, and the lower layer is temporarily supplemented with LED 30 W from June to September to increase young shoot growth.