• Title/Summary/Keyword: oneM2M Standard

Search Result 653, Processing Time 0.027 seconds

TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments (신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응)

  • Choi Yoon-Jung;An Hye-Jung;Kang Mi-Ra;Lee Hye-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

A Study on Application Test of Cut-slope Revegetation Measures with Organic Soil Amendment Materials (유기질계 토양개량재를 이용한 절토비탈면 녹화공법 적용시험 연구)

  • Jeon, Gi-Seong;Woo, Kyung-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.3
    • /
    • pp.13-20
    • /
    • 2005
  • This study was conducted to suggest the ecological restoration methods of the decomposed granite cut-slope by organic soil amendment materials. Field test carried out for the cut-slope with organic soil amendment materials method and other three revegetation methods in Cheongwon. Test revegetation plants were Festuca arundinacea, Lolium perenne, Dactylis glomerata, Lespedeza cyrtobotrya, and Arundinella hirta. The result of this study can be summarized as follows; 1. The soil hardness, the soil acidity, and the soil humidity of organic soil amendment materials method were at a suitable value for plants growth. And it was better as compared with other three revegetation methods of cutting-rock slopes. 2. The result of toxic substance investigation, all items were at a suitable for standard law. 3. During one year after seeding, most plants germinated and especially Festuca arundinacea and Dactylis glomerata grows well. Seedling numbers were 336.7 per $m^2$(after 6 months), 183.3 per $m^2$(after 10 months), and 353.3 per $m^2$(after 6 months). Ten months later after seeding, plants showed 80% ground coverage. Visual rate, plant height, and growth rate were excellence, Also, high plant growth in spring better than autumn.

An Assessment Study for Design Load of a Small Wind Turbine (소형풍력발전기의 설계하중 평가 연구)

  • Hyun, Seung-Gun;Kim, Keon-Hoon;Huh, Jong-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.48-53
    • /
    • 2011
  • In this study, it is to verify the applicability for a simplified model(IEC61400-2, Design Require-ments for Small Wind Turbines, 2006-03) is the international standard is used to the structural design. In the design process of a wind turbine, the safety of a designed wind turbine is one of the most important factors. The simplified model can be used to determine the design load for small wind turbines. So, this paper has been re-evaluated a small wind turbine design loads that produced already. As a result, the material characteristic value(Rchar) of Blade, Rotor shaft and the tower are $90E6[N/m^2]$, $441E6[N/m^2]$ and $94E6[N/m^2]$. Therefore, the value of the applied safety factor to each part of the survival probability of 95% are satisfied.

  • PDF

A Study on Epitrochoidal Tooth Profile in A Two Teeth Difference Cycloidal Reducer (2치수차 사이클로이드 감속기의 형상설계에 관한 연구)

  • Shin J.H.;Kwon S.M.;Kim B.J.;Kim J.C.;Kim M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.389-390
    • /
    • 2006
  • The cycloidal reducer is one of the velocity controlling equipments in machinery. It has advantages of the higher reduction ratio, the higher accuracy, the easier adjustment of the transmission ratio and the smaller workspace than any other kinds of the reducers. This paper proposes a simple and exact approach for the lobe profile design of the two teeth difference cycloidal plate gear, which is different from the standard cycloidal reducer, by means of the principle of the instant velocity center in the general contact mechanism and the homogeneous coordinate transformation.

  • PDF

"Dust, Ice, and Gas In Time" (DIGIT) Herschel Observations of GSS30-IRS1 in Ophiuchus

  • Je, Hyerin;Lee, Jeong-Eun;Green, Joel D.;Evans, Neal J. II
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.63.2-63.2
    • /
    • 2014
  • As a part of the "Dust, Ice, and Gas In Time" (DIGIT) key program on Herschel, we observed GSS30-IRS1, a Class I protostar located in Ophiuchus (d =125 pc), with Herschel/Photodetector Array Camera and Spectrometer (PACS). More than 70 lines were detected within a wavelength range from 50 ${\mu}m$ to 200 ${\mu}m$: CO lines from J = 14-13 to 41-40, several $H_2O$ lines of Eup = 100 K to 1500 K, 16 transitions of OH rotational lines, and two atomic [O I] lines at 63 and 145 ${\mu}m$. The [C II] line, known as a tracer of externally heated gas by the interstellar radiation field, is also detected at 158 ${\mu}m$. All lines, except [O I] and [C II], are detected only at the central spaxel of $9^{\prime\prime}.4{\times}9^{\prime\prime}.4$. The [O I] emission is extended along a NE-SW orientation, which is consistent with the known outflow direction, while the [C II] line is detected over all spaxels. One possible explanation of the detection of the [C II] line and no correlation of its spatial distribution with any other molecular emission is the existence of the enhanced ISRF nearby GSS30-IRS1. One interesting feature of GSS30-IRS1 is that the continuum emission is extended beyond the point-spread function (PSF), unlike the molecular line emission, indicative of significant external heating. The best-fit continuum model of GSS30-IRS1 with the physical structure including flared disk, envelope, and outflow shows that the internal luminosity is 11 $L_{\odot}$, and the region is also externally heated by a radiation field enhanced by a factor of 25 compared to the local standard interstellar field.

  • PDF

Counting and Localizing Occupants using IR-UWB Radar and Machine Learning

  • Ji, Geonwoo;Lee, Changwon;Yun, Jaeseok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.5
    • /
    • pp.1-9
    • /
    • 2022
  • Localization systems can be used with various circumstances like measuring population movement and rescue technology, even in security technology (like infiltration detection system). Vision sensors such as camera often used for localization is susceptible with light and temperature, and can cause invasion of privacy. In this paper, we used ultra-wideband radar technology (which is not limited by aforementioned problems) and machine learning techniques to measure the number and location of occupants in other indoor spaces behind the wall. We used four different algorithms and compared their results, including extremely randomized tree for four different situations; detect the number of occupants in a classroom, split the classroom into 28 locations and check the position of occupant, select one out of the 28 locations, divide it into 16 fine-grained locations, and check the position of occupant, and checking the positions of two occupants (existing in different locations). Overall, four algorithms showed good results and we verified that detecting the number and location of occupants are possible with high accuracy using machine learning. Also we have considered the possibility of service expansion using the oneM2M standard platform and expect to develop more service and products if this technology is used in various fields.

Current Composition Table of Foods in Japan and Future Trends

  • Watanabe, Tomoko
    • Journal of Community Nutrition
    • /
    • v.5 no.2
    • /
    • pp.65-71
    • /
    • 2003
  • In Current Standard Tables of Food Composition in Japan (Fifth Revised Edition), standard composition values of food used regularly in Japan are shown by values per 100g of their edible portion, with one value of standard composition per one foodstuff as a rule. In the Explanation (Chapter 1) and Reference Data (Chapter 4) of the original table, the most important matters are mentioned, including the table of the weight change rate by cooking, the table of the outline of the cookery, and the formula of the actual amount of intake nutrition. These are helpful for an understanding of the actual amount of intake nutrition. The formula for the amount of purchase in consideration of the amount of refuse is also shown. Information concerning foodstuffs and composition items in the table as well as important points in the reference column are concurrently written in English. As related studies, the composition tables by values per 100m1 or considered loss, the table or the formula for estimation of the amount of sucrose, and the list of the composition extant rate after cooking, among others, are also provided. Users should understand the original composition table, and then suggest how to utilize it. (J Community Nutrition 5(2) : 65∼71, 2003)

Development and evaluation of standard samples for quality control of automated total bacterial counter in raw milk (원유 세균수 검사장비의 정도관리를 위한 표준시료의 개발 및 평가)

  • Kang, Hye Jeong;Kim, Jin Hwan;Byun, Yeong Seob;Lee, Hana;Lee, Hye Young;Kim, Jihyeon;Hong, Serim;Kim, Ha-Young;Yoon, Soon-Seek;Moon, Jin-San
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.3
    • /
    • pp.147-154
    • /
    • 2020
  • Standard samples were prepared for this study, and applied for BactoScanTM and BactoCountTM in order for quality control evaluation for total bacterial count in raw milk. Accordingly, the preparation of two lots of standard samples for quality control were lyophilized, which contain Lactobacillus lactis. The standard samples were prepared into three different levels of bacterial counts, those were Low 30,000~40,000, Medium 70,000~90,000, High 150,000~220,000 CFU/mL, respectively. Then, the proficiency tests were performed in total 19 laboratories for measuring total bacterial counts. The total bacterial counts in the standard samples showed 37~42, 82~105, 214~240 CFU/mL in the first lot, and it showed 30~36, 67~75, 131~163 CFU/mL in the second lot in low, medium and high levels, respectively. Based on these results, the absolute values of z-scores of six standard samples in 18 laboratories were ≤2, which means the samples are satisfactory. However, z-score in one laboratory was ≤3, which means the sample is questionable. Using two standard samples, the correlation between BactoScanTM and BactoCountTM was 0.9982, which means the results of total bacterial count measurement of both equipment were equivalent. Therefore, the standard samples manufactured in this study for quality control of total bacterial count using BactoScanTM and BactoCountTM in the raw milk could be applied to proficiency tests.

Ground-motion prediction equation for South Korea based on recent earthquake records

  • Jeong, Ki-Hyun;Lee, Han-Seon
    • Earthquakes and Structures
    • /
    • v.15 no.1
    • /
    • pp.29-44
    • /
    • 2018
  • A ground-motion prediction equation (GMPE) for the Korean Peninsula, especially for South Korea, is developed based on synthetic ground motions generated using a ground motion model derived from instrumental records from 11 recent earthquakes of $M_L$>4.5 in Korea, including the Gyeongju earthquake of Sept. 12. 2016 ($M_L$5.8). PSAs of one standard deviation from the developed GMPE with $M_W$ 6.5 at hypocentral distances of 15 km and 25 km are compared to the design spectrum (soil condition, $S_B$) of the Korean Building Code 2016 (KBC), indicating that: (1) PSAs at short periods around 0.2 sec can be 1.5 times larger than the corresponding KBC PSA, and (2) SD's at periods longer than 2 sec do not exceed 8 cm. Although this comparison of the design spectrum with those of the GMPE developed herein intends to identify the characteristics of the scenario earthquake in a lower-seismicity region such as South Korea, it does not mean that the current design spectrum should be modified accordingly. To develop a design spectrum compatible with the Korean Peninsula, more systematic research using probabilistic seismic hazard analysis is necessary in the future.

Activities of Daily Living of The Elderly with a Chronic Disease and Burden on Family Care-givers (노인 만성 질환자의 일상생활 수행정도와 가족간호자의 부담감)

  • Bang, Su-Hyang;Jang, Hee-Jeong
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.1
    • /
    • pp.135-144
    • /
    • 2007
  • Propose: The purpose of this study was to help families decrease and alleviate the burden on family care-givers taking care of elderly patients. Method: Data was collected by a questionnaire from 100 family members who were registered in the department of home health care nursing at 4 hospitals of H University Medical Center from September 20 to October 25, 2005. The collected data was analyzed using Mean and Standard Deviation, Pearson Correlation Coefficient, t-test and One-Way ANOVA with the Duncan's test, and Stepwise multiple regression. Result: The average burden on family care-givers of elderly patients with chronic diseases was 3.31. The social burden was the highest(M=3.68), the lowest was the emotional burden(M=2.95). In ADL of elderly patients with chronic diseases, all 10 questions showed an average point above 2.50. The dependency level of going up and down the stairs was the highest(M=2.88). Conclusion: This research is necessary for the application of a plan in the social support system in order to reduce the burden on family care-givers who are taking care of elderly patients with a chronic disease.