• Title/Summary/Keyword: oneM2M 표준

Search Result 265, Processing Time 0.029 seconds

Study on IoT Controller for Smart Home Service (스마트홈 서비스를 위한 사물인터넷 컨트롤러에 관한 연구)

  • Kwon, Dong-hyun;Lim, Ji-yong;Heo, Sung-uk;Oh, Am-suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.590-591
    • /
    • 2017
  • In the existing smart home, a separate platform was set up for each manufacturer to provide services through terminals. However, due to the development of Internet technology, various Internet devices and services have been launched, and there is a limit to the existing closed platforms for each manufacturer. Therefore, in this paper, we propose an object internet controller that integrates control of Internet devices in a smart home environment and provides various services through IFTTT. The proposed Internet controller is connected to the server via WiFi, and can control the Internet device and service of objects through the button input event. In addition, we expect to be able to provide a service environment that can create various smart home services by registering DIY products through open platform of oneM2M standard method.

  • PDF

Design and Implementation of IoT Platform-based Digital Twin Prototype (IoT 플랫폼 기반 디지털 트윈 프로토타입 설계 및 구현)

  • Kim, Jeehyeong;Choi, Wongi;Song, Minhwan;Lee, Sangshin
    • Journal of Broadcast Engineering
    • /
    • v.26 no.4
    • /
    • pp.356-367
    • /
    • 2021
  • With the recent development of IoT and artificial intelligence technology, research and applications for optimization of real-world problems by collecting and analyzing data in real-time have increased in various fields such as manufacturing and smart city. Representatively, the digital twin platform that supports real-time synchronization in both directions with the virtual world digitized from the real world has been drawing attention. In this paper, we define a digital twin concept and propose a digital twin platform prototype that links real objects and predicted results from the virtual world in real-time by utilizing the oneM2M-based IoT platform. In addition, we implement an application that can predict accidents from object collisions in advance with the prototype. By performing predefined test cases, we present that the proposed digital twin platform could predict the crane's motion in advance, detect the collision risk, perform optimal controls, and that it can be applied in the real environment.

Extraction of Ground Control Points from TerraSAR-X Data (TerraSAR-X를 이용한 지상기준점 추출)

  • Park, Jeong-Won;Hong, Sang-Hoon;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.299-307
    • /
    • 2008
  • It is possible to extract qualified ground control points (GCPs) from SAR data itself without published maps. TerraSAR-X data that are one of highest spatial resolution among civilian SAR systems is now available. In this study, a sophisticated method for GCP extraction from TerraSAR-X data was tested and the quality of the extracted GCPs was evaluated. Mean values of the distance errors were 0.11m and -3.96 m with standard deviations of 6.52 m and 5.11 m in easting and northing, respectively. The result is one of the best among GCPs possibly extracted from any civilian remote sensing systems. The extracted GCPs were used for geo-rectification of IKONOS image. The method used in this study can be applied to KOMPSAT-5 for geo-rectification of high-resolution optic images acquired by KOMPSAT-2 or follow-up missions.

Design and Implementation of Arduino-based Lightweight Vibration Monitoring System (아두이노 기반의 경량 진동 모니터링 시스템 설계 및 구현)

  • Kwon, Dong-hyun;Lim, Ji-yong;Heo, Sung-uk;Oh, Am-suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.586-589
    • /
    • 2017
  • The vibration monitoring system using the sensor network is used in various fields. However, in case of the vibration of the existing products, the size of the monitoring system is increased due to the separation of the sensor data collection function and the communication function. In this paper, we design and implement a lightweight vibration monitoring system using the MQTT protocol, which is oneM2M device standard protocol for the Arduino and Ethernet modules, to monitor frequent earthquakes and vibrations in narrow places.

  • PDF

IoT 상호운용성 및 서비스 개발

  • Go, Yeong-Jun;Kim, Yong-Jin
    • Information and Communications Magazine
    • /
    • v.32 no.5
    • /
    • pp.31-35
    • /
    • 2015
  • IoT 서비스 사업자, IoT 기기 공급업체 또는 산업분야별로 구축한 IoT 서비스가 파편화돼 가는 상황에서 IoT 플랫폼간 상호운용성(Interoperability) 관련 기술 개발의 필요성이 증대되고 있다. 본 논문에서는 IoT 서비스 플랫폼간의 상호운용성 및 IoT 디바이스간의 상호운용성을 개선하기 위한 플랫폼간 연동(Interworking) 기술 및 개방형 표준 플랫폼 기술 적용 방안을 제시하였으며 사용 편의를 위한 상황인식(Context-Awareness) 기술 구현안을 제시하였다. 본 논문에서는 모다정보통신이 개발한 oneM2M 국제표준 기반의 지능형 IoT 플랫폼인 OMNIPASS와 다양한 IoT 플랫폼 간의 상호연동성을 지원하는 IoT Gateway장치로서 Smart Brain을 소개하고 이를 통해 IoT 서비스의 발굴과 다양한 산업 응용 분야의 확산을 도모하고자 한다.

Deep Learning and IoT Standards based High Rise Fieldworker's Behavior Analysis System (딥러닝과 IoT 표준을 이용한 고소 작업자 행동분석 시스템)

  • Lee, Se-hoon;Kang, Gun-ha;Sim, Gun-wu;Tak, Jin-hyun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.247-248
    • /
    • 2019
  • 본 논문에서는 블루투스 비콘을 이용해 고소 작업장 등의 위험지역에서 작업자 추적 및 확인과 안전 벨트고리를 체결했는지 여부와 작업자의 행동에 따른 데이터를 추가로 수집하여 작업자의 행동 패턴을 분석하였다. IoT 국제 표준인 oneM2M을 기반으로 IoT Device와 Application을 연결하는 중간 매개체로 모비우스 플랫폼을 사용해 시스템을 구축하였다. 또한, 본 연구팀의 선행 연구에서 작업자 위험 행동분류 시스템을 개선할 수 있는 연구 결과를 비교하였다.

  • PDF

우리나라의 천문측지 지오이드에 관한 연구

  • 조규전;이영진
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.2
    • /
    • pp.1-8
    • /
    • 1991
  • The geoid is the one of major suject in Geophysics and Geodesy. The iregularities of the geoid will affect the computation of precise geodetic coordinates and moreover will cause an errors in trajectory computations and reference directions for inertial guidance system. The aim of this study is to develope the best local geoid model for Korea. For this purpose, an astrogeodetic levelling and surface fitting techniques have been applied in determination of the geoid as a first trials. As a result of it, a local geoid has been obtained with the standard errors of $\pm$0.49m and $\pm$0.66m respectively and the maximum geoid undulation in Korea is found as 22m~23m approximately.

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

Development of Line Standards Measurement System Using an Optical Microscope (광학 현미경을 이용한 선표준물 측정 시스템 개발)

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.8
    • /
    • pp.72-78
    • /
    • 2009
  • We developed a line standards measurement system using an optical microscope and measured two kinds of line standards. It consists of three main parts: an optical microscope module including a CCD camera, a stage system with a linear encoder, and a measurement program for a microscopic image processing. The magnification of microscope part was calibrated using one-dimensional gratings and the angular motion of stage was measured to estimate the Abbe error. The threshold level in line width measurement was determined by comparing with certified values of a line width reference specimen, and its validity was proved through the measurement of another line width specimen. The expanded uncertainty (k=2) was about 100 nm in the measurements of $1{\mu}m{\sim}10{\mu}m$ line width. In the comparison results of line spacing measurement, two kinds of values were coincide within the expanded uncertainty, which were obtained by the one-dimensional measuring machine in KRISS and the line standards measurement system. The expanded uncertainty (k=2) in the line spacing measurement was estimated as $\sqrt{(0.098{\mu}m)^2+(1.8{\times}10^{-4}{\times}L)^2}$. Therefore, it will be applied effectively to the calibration of line standards, such as line width and line spacing, with the expanded uncertainty of several hundreds nanometer.

Development of chemical ionization method in a GC-TOF mass spectrometer for accurate mass and isotope ratio measurement (Accurate mass 및 isotope ratio 측정을 위한 GC-TOF 질량분석기에서의 화학적 이온화방법)

  • Chung, Joo-Hee;Na, Yun-Cheol;Hwang, Geum-Sook;Shin, Jeoung-Hwa;Ahn, Yun-Gyong
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • An accurate mass and isotope ratio were determined using a gas chromatography/time of flight mass spectrometer in CI positive mode for the identification of unknown metabolites. High mass tune was used to improve the ion intensity of $[M+H]^+$. Chromatographic resolution and dynamic range enhancement were performed to obtain more reliable accurate masses and correct isotope abundance ratios. Average absolute errors of mass and isotope ratios for 24 reference metabolite -TMS (trimethylsilyl) derivatives were 6.8 ppm, 1.5% of (M+1/M ratio) and 1.7% of (M+2/M ratio), respectively. The correct formulas of twenty one compound were retrieved within top-2 hit from the heuristic algorithm for elemental composition using each accurate mass and isotope abundance ratio.