• Title/Summary/Keyword: on-site testing

Search Result 452, Processing Time 0.029 seconds

Effects of Wearing between Respirators and Glasses Simultaneously on Physical and Visual Discomforts and Quantitative Fit Factors (안면부 여과식 방진마스크와 안경 동시 착용 시 불편감과 밀착계수 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.52-60
    • /
    • 2018
  • This study compares the differences of the fit factor by the order of wearing preference between Particulate filtering facepiece respirators(PFFR) and glasses when participants wore simultaneously and a survey of physical and visual complaint. Recognition level about fit of respirators was investigated and the educational (before- and after-) effect of the fit factor. When participants wore PFFR and glasses, physical complaints were nose pressure, slipping, nose and ear pressure, ear pressure and rim loosen, the most highly physical complaints were nose pressure. Visual complaints were demister, blurry vision, dizziness, visual field, and lens dirty, the most highly visual complaints were demister. But, there was significant difference in physical complaint such as nose pressure(10.3%), slipping (23.0%), nose and ear pressure(14.3%), and rim loosen(16.2%), visual complaint such as visual field(13.8%) and lens dirty(32.4%). For the recognition of fit of respirators, respirators fitness, leak site, an initial point and an object, faulty factor, recognition level was higher. Fit factor was increased after education of proper wearing of respirator. Change of the fit factor was smaller compared to the normal breathing and after 6 actions in case of after education. Questionnaire consisted of general characteristics and physical/visual complaint, recognition of fit. Complaints were measured after the QNFT with multiple choices. Quantitative fit factor was measured by device and compared the result of (before- and after-) educational effect. Also, we selected to 6 actions (Normal breathing, Deep breathing, Bending over, Turning head side to side, Moving head up and down, Normal breathing) among 8 actions OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The fit factor was higher after the training (p=0.000). Descriptive statistics, paired t-test, and Wilcoxon analysis were performed to describe the result of questionnaire and fit test. (P=0.05) Therefore, it is necessary to investigate the quantitative research such as training program and glasses fitting factor about the wearing of PFFR and glasses simultaneously.

Measurement of Streambed Hydraulic Conductivity in Stream Sections in the Anseongcheon Watershed, Korea (안성천 수계 국가하천구간 하상 수리전도도 측정 시험)

  • Jeon, Seon-Keum;Lee, Il Hoon;Lee, Jeongwoo;Chung, Il-Moon;Hong, Sung Hun
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.377-382
    • /
    • 2017
  • Field experiments were conducted to estimate streambed hydraulic conductivity at 15 sites in the Anseongcheon watershed, Korea. Seepage meters and piezometers were installed in the streambed at each site to measure the amount of stream water-groundwater exchange and the hydraulic gradient. The vertical hydraulic conductivity was then calculated using Darcy's formula. The measured stream water-groundwater exchange rates were $4.08{\times}10^{-6}$ to $1.49{\times}10^{-5}m/s$, and the vertical hydraulic gradients were 0.005 to 0.145. The data suggest the streambed hydraulic conductivity to be $7.80{\times}10^{-5}$ to $1.58{\times}10^{-3}m/s$. The results show significant differences in connectivity between stream and aquifer. Quantification of the hydraulic interconnection between stream and aquifer, and evaluation of the effects of groundwater development and utilization on the streamflow require hydrogeological investigations of the connection between stream and aquifer, including the hydraulic conductivity of the streambed. Various field testing and analysis methods for hydrogeological assessment also require further improvement.

Proposal of Design Method for Landslides Considering Antecedent Rainfall and In-situ Matric Suction (선행강우와 현장 모관흡수력을 고려한 산사태 해석 방법 제안)

  • Kim, Jung-Hwan;Jeong, Sang-Seom;Kim, Yong-Min;Lee, Kwang-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.12
    • /
    • pp.11-24
    • /
    • 2013
  • This study presents a design method for typical rainfall-induced landslide considering in-situ matric suction. Actual landslide data are used to validate the proposed method. The soil-water characteristic curve (SWCC) and unsaturated permeability are experimentally determined to estimate hydraulic properties of testing site. The field measurement of matric suction is carried out to monitor in-situ matric suction in a natural slope subjected to rainfall infiltration, which is incorporated in the landslide analysis. The wetting band depth and safety factor of the slope are assessed to clarify the effect of domestic rainfall pattern. Especially, the effect of antecedent rainfall on the slope stability is investigated and discussed in terms of wetting band depth using parametric study. It is found from the result of this study that proposed design method can consider the characteristic of unsaturated soil and effect of antecedent rainfall. The location of the scarp zone is fairly well predicted by proposed design method. Moreover, heavy rainfall, concentrated in the backward part with time, causes the lowest safety factor of the slope. These results demonstrate that decrease in matric suction due to antecedent rainfall may trigger slope instability. After the antecedent rainfall, additional rainfall may cause the slope failure due to increasing wetting band depth.

Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect (전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향)

  • Shim, Jae-Chang;Kim, Young-Jun;Chung, Hyun-Ju;Kim, Ok-Su
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

The Development of Traffic Queue Length Estimation Algorithm Using the Occupancy Rates (점유율을 이용한 대기행렬길이 추정 알고리즘 개발)

  • Kang Jihoon;Oh Young-Tae;Kang Jeung-Sik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.2 s.7
    • /
    • pp.13-22
    • /
    • 2005
  • The purpose of this research is how to estimate the traffic queue length in the signal intersection accurately. The current traffic queue length algorithm in COSMOS has been using the congestion diagram which comes from the speed of an average separated vehicle - using average vehicle length and the occupancy time from loop detectors. So some errors were occurred by the speed estimation method using average vehicle lengths. And Operators had been difficult to optimize some variables for measuring the traffic queue length estimation algorithm in COSMOS. Therefore the traffic queue length estimation algorithm on the basis of the relation between distances and occupancy rates from loop detectors was developed in this thesis. This thesis had the advantage of using occupancy rates which came out from loop detectors easily and no need to optimize some variables for the established algorithm in COSMOS. And the results of testing this algorithm in some sites which had installed COSMOS system showed better results than COSMOS system's results. But it was noted that further studies which carry it out in various sites and under various cases are necessary for applying to actual intersections.

  • PDF

Carrying Capacity Behavior of Instrumented PC Piles (시험 콘크리트 말뚝의 지지력 거동)

  • 이영남;이종섭
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.163-172
    • /
    • 1998
  • To study the carrying capacity behavior of pile, dynamic pile testis and static load tests were carried out on two instrumented piles during and some time after pile driving. Cone Penetration Test( CPT) and Standard Penetration Test(SPT) were also performed at the test site before pile tests to investigate the relationship between unit skin friction of piles and cone tip resistance values and SPT N values. Total static capacity of pile reached the ultimate stage at the pile head settlement of about 0.055D (D : Pile diameter), at which skin friction of Pile already Passed the maximum value, but the end bearing was still increasing with the pile head settlement. The carrying capacity of pile increased in the form of natural logarithmic function with the time after pile driving. The increase in skin friction with time was very substantial the increase in skin friction 40 days after pile driving was 4.6 times of that determined during pile driving. The contribution of skin friction to the total capacity twas insignificant in the beginning, but became substantial 40 days after pile driving. This implies that the tested pile initially responded as an end bearing pile and later behaved as a friction pile. It was also noted that unit skin friction of pile might be ielated to cone tip resistance values(q.) and SPT N values, though the coefficient of this relationship might differ from one soil group to another and was somewhat greater than the value used in the design practice of Korea.

  • PDF

Development of Thinning Effect Analysis Model (TEAM) Using Individual-Tree Distance-Independent Growth Model of Pinus koraiensis Stands (잣나무 임분의 개체목 거리독립생장모델을 이용한 간벌효과 분석모델 개발)

  • Kwon, Soonduk;Kim, Seonyoung;Chung, Joosang;Kim, Hyung-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.6
    • /
    • pp.742-749
    • /
    • 2007
  • The objective of this study was to develop thinning effect analysis model (TEAM) using individual-tree distance-independent growth model of Pinus koraiensis Stands. The TEAM was designed to analyze thinning effects associated with such thinning prescriptions as the number, timing, intensity, and method of thinnings. To testing TEAM application, stand growth effects were compared with seven scenarios according to thinning prescription plan. In the results, it was possible to estimate the number of trees, height, volume with diameter (DBH) class of individual trees, and average diameter growth, height growth, the number of trees and volume growth per ha of stands. The result of sensitivity analysis on one Pinus koraiensis stand, it was not sure to expect the much more volume at the rotation age by stand density control applying thinning prescription. In the case of thinning, total yield volume has much more $40{\sim}75m^3$ per ha, within 5 cm in average diameter growth and within 1 m in average height growth than thats of non-thinning over increasing stand age. TEAM, as decision making support system, can be used for selecting the thinning prescription trial and determining one of some thinning prescription plan in different site specific stand environments.

A Decade's Experiences on the Hydrofracturing In-Situ Stress Measurement for Tunnel Construction in Korea (암반터널 설계를 위한 수압파쇄 초기지압 측정의 10여년 간의 경험)

  • Choe, Seong-Ung;Park, Chan;Sin, Jung-Ho;Sin, Hui-Sun
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.03a
    • /
    • pp.79-88
    • /
    • 2008
  • Since the hydraulic fracturing field testing method was introduced first to Korean geotechnical engineers in 1994, there have been lots of progresses in a hardware system as well as an interpretation tool. The hydrofracturing system of first generation was the pipe-line type, so it was not easy to handle. It had been modified to a wire-line system at their second generation. It was more compact one but it also needed an additional air-compressor. Our current system is much more compact and operated by all-in-one system, so it doesn't need an additional air-compressor. With a progress in a hardware system, the software for analyzing the in-situ stress regime has also been progressed. For example, the shut-in pressure, which is the most ambiguous parameter to be obtained from hydrofracturing pressure curves, can now be acquired automatically from the various methods. While the hardware and software for hydrofracturing tests are being developed during the last decade, the author could accumulate the field test results which can cover the almost whole area of South Korea. Currently these field data are used widely in a feasibility study or a preliminary design step for tunnel construction in Korea. Regarding the difficulties in a site selection and a test performance for the in-situ stress measurement at an off-shore area, the in-situ stress regime obtained from the field experiences in the land area can be used indirectly for the design of a sub-sea tunnel. From the hydrofracturing stress measurements, the trend of magnitude and direction of in-situ stress field was shown identically with the geological information in Korea.

  • PDF

Identification of process generating formaldehyde in a furniture manufacturer (특정 가구 제조 공장의 포름알데히드 발생 공정 노출 평가)

  • Yoo, Kye-Mook;Lee, Mi-Young
    • Analytical Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.243-247
    • /
    • 2014
  • Formaldehyde is defined as carcinogen causing leukaemia, lymphoma or nasopharyngeal carcinoma at high level of exposure. Furniture-manufacturing workers can be exposed to formaldehyde, which implies serious impact on health of the workers. The authors carried out ambient monitoring of formaldehyde in the field, and identified the source of formaldehyde generated during the working process by testing the condition in the laboratory settings. After sampling formaldehyde in the air with 2,4-DNPH (2,4-dinitrophenylhydrazine) coated silica gel, we extracted formaldehyde derivative with acetonitrile and analyzed the extract using HPLC with UV detector at 360 nm. Formaldehyde was separated by ACQUITY UPLC BEH $C_{18}$ column at a flow rate of 0.5 mL/min using 45% acetonitrile as mobile phase. The workers were exposed to higher level of formaldehyde than normal air. Formaldehyde up to 0.31 ppm was detected in the process of veneer attachment, which exceeded 0.3 ppm, the ceiling value of ACGIH standard. The laboratory test of measuring formaldehyde generated from the glue and veneer used in the attachment process resulted in more formaldehyde generation as the temperature increased, and more from the veneer. Heating the veneer to $100-150^{\circ}C$ following the real condition of the manufacturing site generated 1.14-2.70 ppm of formaldehyde from the sample, which was 2-5 times higher level than Korean limit of exposure (0.5 ppm). As the workers handling and processing the veneer which was produced by wet process had high possibility to be exposed to formaldehyde, urgent improvement and management of working environment of furniture manufacturer is demanded.

A COMPARATIVE STUDY ON THE FRACTURE STRENGTH AND MARGINAL FITNESS OF FIBER-REINFORCED COMPOSITE BRIDGE (섬유강화형 복합레진브릿지의 파절강도 및 변연적합도에 관한 연구)

  • Choi Ho-Kuen;Shin Sang-Wan;Lim Ho-Nam;Suh Kuyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.526-546
    • /
    • 2001
  • Fiber-reinforced composite(FRC) was developed as a structural component for dental appliances such as prosthodontic framework. FRC provides the potential for fabrication of a metal-free, excellent esthetic prostheses. It has demonstrated success as a result of its simple fabrication, natural colour, and marginal integrity, and fracture resistance of veneering composite resin and the FRC material. Although it has lots of merits, clinical and objective data are insufficient. The purpose of this study was to evaluate the fracture strength and the marginal fitness of fiber reinforced composite bridge in the posterior region for clinical application. Sixteen bridges of each group. $Targis/Vectris^{(R)}$, $Sculpture-Fibrekor^{(R)}$, and In-Ceram, were fabricated. All specimens were cemented with Panavia 21 to the master dies. Strength evaluation was accomplished by a universal testing machine (Instron). The marginal fitness was measured by using the stereoscope (${\times}50$). The results were as follows. : 1. The fracture strength according to the materials was significantly decreased in order In-Ceram($238.81{\pm}82$), Targis Vectris($176.25{\pm}18.93$), Sculpture-Fibrekor($120.35{\pm}20.08$) bridges. 2. FRC resin bridges were not completely fractured, while In-Ceram bridges were completely fractured in the pontic joint. 3. The marginal accuracy was significantly decreased in order Targis/Vectris ($60.71{\mu}m$), Sculpture-Fibrekor($73.10{\mu}m$) In-ceram Bridge ($83.81{\mu}m$). 4. The fitness of occlusal sites had a lower value than the marginal sites(P<0.001), and the marginal gaps of inner site of the pontic were greater than that of outer sites of the pontic. Fiber reinforced composite bridges are new, esthetic prosthesis and can be clinically used in anterior regions and short span bridges. However, caution must be exercised when extrapolating laboratory data to the clinical situation because there are no long term clinical data regarding the overall success of the FRC.

  • PDF