• 제목/요약/키워드: on-off control

검색결과 2,539건 처리시간 0.034초

입력 불일치 해소에 의한 개선형 무충돌전환 (An Improved Bumpless Transfer by Solving the Input Discrepancy Problem)

  • 김태신;양지혁;권태완;권오규
    • 제어로봇시스템학회논문지
    • /
    • 제15권10호
    • /
    • pp.982-987
    • /
    • 2009
  • On the controller switching time, even though on-line/off-line controller outputs are the same, a problem which deteriorates the performance of bumpless transfer can happen in case that any discrepancy between the two controller inputs is transferred directly to the controller output. In this paper, we analyze the cause of that phenomenon in existing research results and propose a new method which improves that problem. In order to solve this problem, the off-line controller is augmented to an anti-windup structure and an improved bumpless transfer method is derived by using the changed input of the off-line controller instead of the plant input. We exemplify the performance of the proposed method by comparing with the performance of the existing method via numerical examples.

High-Power-Factor Boost Rectifier with a Passive Energy Recovery Snubber

  • Kim, Marn-Go;Baek, Seung-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.668-676
    • /
    • 1998
  • A passive energy recovery snubber for high-power-factor boost rectifier, in which the main switch is described in terms of the equivalent circuits that are operational during turn-on and turn-off sequences. These equivalent circuits are analyzed so that the overshoot voltage across the main switch, the snubber current, and the turn-off transition time can be predicted analytically. The main switch combined with proposed snubber can be turned on with zero current and turned off at limited voltage stress. The high-power-factor boost rectifier with proposed snubber is implemented, and the experimental results are presented to confirm the validity of proposed snubber.

  • PDF

Optimal Excitation Angles of a Switched Reluctance Generator for Maximum Output Power

  • Thongprasri, Pairote;Kittiratsatcha, Supat
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1527-1536
    • /
    • 2014
  • This paper investigates the optimal values of turn-on and turn-off angles, and ratio of flux linkage at turn-off angle and peak phase current positions of optimal control for accomplishing maximum output power in an 8/6 Switched Reluctance Generator (8/6 SRG). Phase current waveform is analyzed to determine optimal excitation angles (optimal turn-on and turn-off angles) of the SRG for maximum output power which is applied from a nonlinear magnetization curve in terms of control variables (dc bus voltage, shaft speed, and excitation angles). The optimal excitation angles in single pulse mode of operation are proposed via the analytical model. Simulated and experimental results have verified the accuracy of the analytical model.

개선된 소프트 스위칭 Two-transistor forward converter (An Improved Soft Switching Two-transistor Forward Converter)

  • Kim, Marn-Go
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.137-140
    • /
    • 2000
  • This paper proposes an improved soft switching two-transistor forward converter which uses a novel lossless snubber circuit to effectively control the turn-off dv/dt rate of the main transistors. In the proposed soft switching implementation the turn-off voltage traces across the main two transistors are almost the same contributing to reduce the total capacitive turn-on loss and the snubber current is divided into the two transistors resulting in distributed thermal stresses

  • PDF

시간지연이 큰 미지의 시스템에 대한 최적 P.I.D 제어기 설계 (Design of optimal P.I.D controller for unknwon long time delayed system)

  • 박익수;문병희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.164-167
    • /
    • 1996
  • This paper presents an off-line P.I.D parameter estimation method during normal operation in power plant. The process parameters are estimated using the recursive least square method. The controller parameters are estimated on the basis of desired characteristics of the dynamic model of the closed-loop control.

  • PDF

농도구배가 삼지화염의 부상특성에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Lift-off Characteristics of the Triple Flame with Concentration Gradient)

  • 서정일;김남일;오광철;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.7-14
    • /
    • 2004
  • The lift-off characteristics of the triple flame have been studied experimentally with various mean velocities and concentration gradients using a multi-slot burner, which can control the concentration gradient and the mean velocity independently, Lift-off height, axial maximum velocity, flame temperature, and some other characteristics were examined for methane and propane flame, It was found that minimum values of the lift-off heights exist at a certain concentration gradient for constant mean velocity, and this result implies that the propagation velocity has a maximum value at this condition, OH radical distribution was measured with LIF method and velocity variation along streamline was measured with PlV system. In addition maximum temperature along streamline was measured with CARS system. The intensity of the diffusion flame affects on the propagation velocity of triple flame in the region of very weak concentration gradient.

  • PDF

연료량 변조법에 의한 연료분사식 가솔린엔진의 공연비 제어 (Modulated Fuel Feedback Control of a Fuel Injection SI Engine)

  • 박경석;박진일;고상근;노승탁;이종화
    • 한국자동차공학회논문집
    • /
    • 제4권3호
    • /
    • pp.102-111
    • /
    • 1996
  • For the air-fuel ratio control in a fuel injection SI engine, the Jump-Ramp control algorithm has been widely adopted by using the on/off type oxygen sensor. But the Jump-Ramp control method has limitation on treating the frequency and amplitude of the air-fuel ratio oscillation. This study suggests another feedback control logic named modulated fuel feedback control, which has a concept of pre-tuned air-fuel ratio oscillation. In the modulation method, the oxygen sensor output is not treated as on/off signal but as analog signal for feedback. By using the modulation method, the frequency and the amplitude of air-fuel ratio oscillation can be adjustable to some extent for improving the conversion efficiency of the Three-Way Catalyst. The result shows that the performance of the modulation method is better than that Jump-Ramp control method in reducing the amplitude of the air-fuel ratio oscillation as well as in increasing the frequency of the air-fuel ratio oscillation.

  • PDF

PRT 시스템의 역수용 용량결정에 관한 연구 (A Study on the Capacity of the Off-line Station for PRT System)

  • 이준호;정락교
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1070-1074
    • /
    • 2010
  • In this study we deal with a simple computer simulation algorithm to decide the PRT station capacity. PRT system is different from the conventional rail traffic system in such point that the station is off-line so as to guarantee a very short headway. This characteristic has correlation with the accurate prediction of the line capacity and with the scale of the off-line station. In this paper physical factors and vehicles per hour that are necessary to decide the off-line station scale and the off-line station capacity, respectively, are shown through a simple compter simulations.

Voltage Distortion Suppression for Off-grid Inverters with an Improved Load Current Feedforward Control

  • Geng, Yiwen;Zhang, Xue;Li, Xiaoqiang;Wang, Kai;Yuan, Xibo
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.716-724
    • /
    • 2017
  • The output voltage of an off-grid inverter is influenced by load current, and the voltage harmonics especially the 5th and 7th are increased with nonlinear loads. In this paper, to attenuate the output voltage harmonics of off-grid inverters with nonlinear loads nearby, a load current feedforward is proposed. It is introduced to a voltage control loop based on the Positive and Negative Sequence Harmonic Regulator (PNSHR) compensation to modify the output impedance at selective frequencies. The parameters of the PNSHR are revised with the output impedance of the off-grid inverter, which minimizes the output impedance of the off-grid inverter. Experimental results verify the proposed method, showing that the output voltage harmonics caused by nonlinear loads can be effectively suppressed.

인터넷 기반의 온실 환경 제어 시스템에 관한 연구 (A Study on System for Environmental Control in the Greenhouse using Internet)

  • 김대업;박흥복
    • 정보처리학회논문지D
    • /
    • 제8D권4호
    • /
    • pp.427-438
    • /
    • 2001
  • 현재 국내에 보급되어 있는 시설 원예를 위한 온실 환경 제어 시스템은 노동 집약적 시설에 타이머를 이용하여 각 장치를 제어하는 on/off 식 제어반으로 구성되어 있다. 이러한 시스템은 하드웨어적인 결함, 야간이나 원격지에 있을 경우에는 오류 발생 등에 대한 온실의 상태 파악이 어렵다. 따라서, 본 논문에서는 기존의 on/off식 제어 방식을 현장에서는 액정 패널로 제어하도록 하였고, 온실의 각 장치를 제어하는 클라이언트 컴퓨터를 통하여 인터넷상에서 원격지의 데이터 획득과 온실의 상황을 모니터링할 수 있는 시스템을 개발하였다. 또한 각 지역별 온실과도 통신이 가능하며 오류 발생시에도 실시간으로 대처하는 경보 메시지 전송, 그리고 효율적인 온실 환경 제어 및 작물 재배 정보들을 관리할 수 있는 Web 서버를 구축하였다.

  • PDF