• Title/Summary/Keyword: on-line monitoring of drinking water

Search Result 7, Processing Time 0.032 seconds

A study on the application of water safety plans for the hazard risk management of tap water (수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구)

  • Kim, Jinkeun;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

Optimum Coagulation of Water Treatment Plant using On-line Floc Monitoring System (정수장 응집제주입 최적화를 위한 플럭 모니터링)

  • Hwang, Hwando;Lim, Sangho;Sung, Kyujong;Han, Youngjin;Kim, Youngbeom;Kwak, Jongwoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.397-406
    • /
    • 2009
  • This study was conducted to monitor the floc sizes forming in the mixing zone in the water treatment plant. The dosing amount of poly aluminium chloride(PAC) was determined by particle dispersion analyzer(iPDA) in the lab and field scale test. During a field test period, PAC coagulant was used and the raw water was taken from Nakdong river. PAC wad diluted to activate the coagulant, leading to bring the more homogeneous dispersion in the shorter time. To monitor the floc sizes, the unit of floc size index(FSI) was used. With increasing of raw water turbidity, FSI value was increased. Also, the increased dosing amount of PAC brought the increased FSI and with overdosing of coagulant was in turn decreased. When the PAC was fed into the raw water after dilution in a field scale test, the width of FSI was narrower compared with the feeding of the mother liquor of PAC, implying that the formed flocs are denser and more uniform sizes. The width of FSI in average was varied on depending on the basicity of coagulant. Also, dF value, fractal dimension was evalued with the different coagulants, showing from 2.01 to 2.03. On-line floc monitor was effective for the optimal dosing in the drinking water plant.

Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water (음용수 중 수은 연속자동측정시스템의 개발에 관한 연구)

  • Chang, Soo-Hyun;Kim, Hyo-Jin;Kim, Sun-Tae;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.299-305
    • /
    • 1999
  • The electrolyte cathode atomic glow discharge (ELCAD) is a new plasma source for direct determination of trace heavy metals in drinking and waste water. ELCAD has been successfully developed for on-line monitoring of heavy metals, however, shows difficulty to measure mercury. In this study, ELCAD has been modified to apply the atomic absorption spectrometry (AAS) for the direct determination of trace elements of mercury in flowing water.The fundamental characteristics of this new types of plasma source have been investigated and found that the pH of the solution, discharge voltage, and current are most important factors.The absorbance of 1.0 ppm Hg standard solution increases as pH of the solution increases from pH 1.0 to 3.0.However, % RSD of the absorbance also increases as the pH of solution increasesdue to plasma unstability.The detection limits of the standard solution of pH 1.5 and pH 3.0 are about 40 ppb and 10 ppb level, respectively.

  • PDF

Evaluation of Biological Activated Carbon Using Particle Counter (입자계수기를 이용한 생물활성탄 공정의 효율평가)

  • Kim, Hee gune;Ryon, Dong choon;Kim, Hyun sil;Ryu, Byung soon;Moon, Seong yong;Kim, Seung Hyun;Kim, Won Kyong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.823-828
    • /
    • 2006
  • For this study, an online particle counter was installed before and after the activated carbon filtration process of D water treatment plant where has advanced water treatment processes, produces average 900,000ton/day of drinking water and supply the produced drinking water to Busan citizens. We collected and analyzed particle count data for about 1 year. We inspected particle breakthrough in three out of sixteen filter processes operated at same conditions, i.e. 5th filter, 6th filter and 7th filter. According to the monitoring results, 6th and 7th filters showed similar results while 5th filter showed different results. When compared seasonal effect, the particle count for dry season was below 10 particles/ml while the particle count for August when monthly average rainfall is over 200mm was much higher than for dry season. In January and August, there was a difference in breakthrough particle size. In January, small particles in 2~3um were mainly detected while in August 10um particles were mainly detected and the size distribution was 40% of total count.

Correlation between Corrosion Rate and Red Water on Application of Corrosion Inhibitor in Drinking Water Distribution System (배급수 계통에서 부식억제제 적용에 따른 부식과 적수와의 상관관계)

  • Woo, Dal-Sik;Ku, Sung-Eun;Lee, Byung-Doo;Kim, Ju-Hwan;Moon, Kwang-Soon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • This study was performed to evaluate the application of corrosion inhibitor and to examine the correlation between corrosion rate and red water in a series of batch tests and a test using auto corrosion monitoring system at A water treatment plant in Gyeonggido. The corrosion study in the auto corrosion monitoring system indicated that Fe concentration decreased by 30~50% and corrosion rate also reduced remarkably with corrosion inhibitor at $1.8mg\;PO_4/L$. After addition of corrosion inhibitor, it was indicated the effective adsorption of the inhibitor on the surface of the pipe line forming a protective film. The corrosion rate increases with the increase in Fe concentration. With $1.8mg\;PO_4/L$ of corrosion inhibitor, the corrosion rate decreased remarkably. Fe concentration had correlation to not only red water problems but also the corrosion rate that actually dissolved into the water, primarily due to the deposition of oxidized iron or other compounds as a scale, which serves as a large reservoir of corrosion by-product. Therefore, corrosion rate can be estimated by Fe concentration. For these reasons, an effective corrosion inhibitor is also an effective red water control reagent. The effect of the corrosion inhibition can last for some time even the application the corrosion inhibitor is discontinued. For the cost effective and efficient corrosion control, the concentration and timing of corrosion inhibitor addition must be determined properly.

On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant (정수장 응집혼화공정에서의 응집플럭 연속 모니터링)

  • Ga, Gil-Hyun;Jang, Hyun-Sung;Kim, Young-Beom;Kwak, Jong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.263-271
    • /
    • 2009
  • This study evaluated the flocs forming characteristics in the mixing zone to increase the coagulation effect in the drinking water plant. As a measuring tool of formed flocs, on-line particle dispersion analyzer (iPDA) was used in Y drinking water plant. To evaluate the forming flocs, many parameters such as poly amine, coagulant dosing amount, raw water turbidity, and pH was applied in this study. During the periods of field test, poly aluminium chloride (PACl) as a coagulant was used. With the increase of the raw water turbidities, poly amine was also added as one of aids for increasing in coagulation efficiency. The turbidity and pH of raw water was ranged from 7 to 9 and from 25 to 140 NTU, respectively. The increasing of raw water turbidity brought the bigger floc sizes accordingly. From a regression analysis, $R^2$ value was 0.8040 as a function of T, raw water turbidity. Floc size index (FSI) was obtained from a correlation equation as follows; FSI = 0.9388logT - 0.3214 Also, polyamine gave the bigger flocs the moment it is added to the coagulated water in the rapid mixing zone. One of parameters influencing the floc sizes was the addition of powdered active carbon(PAC) in the mixing zone. In case of higher turbidity of raw water, $R^2$ value was 0.9050 in the parameters of [PACl] and [PAC]; FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ On-line floc monitor was beneficial to evaluate the flocs sizes depending on the many parameters consisting raw water properties, bring the profitable basic data to control the mixing zone more effectively.

Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment (막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자)

  • Lee, Yong-Soo;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2017
  • Pressurized membrane module systems, including hollow fiber type of Microfiltration (MF) and Ultrafiltration (UF) membranes are being increasingly used in drinking water treatment due to their high removal efficiency of pathogen. However, when fibers are damaged in pressurized membrane system, the pathogen will be able to penetrate the membrane. Therefore, it is essential to guarantee the regulatory requirements for water quality by an effective on-line or off-line condition integrity monitoring methods. Recently, pressure decay test (PDT) which is one of membrane integrity tests has been reflected to drinking water treatment plants using pressurized membrane module. In this paper, three different method were used to perform PDT and three different sensitivity values were analyzed through experiments. Three types of direct integrity test methods were applied to pressure feed side, filtrate side and bidirectional pressure decay test. The results of these experiments show that the sensitivity was increasing when the volume of pressurized gas was decreasing. The sensitivity is inversely proportional to the gas volume. Furthermore, it is desirable to increase pressure difference between feed side and permeate side in order to achieve higher sensitivity in the PDT by membrane damage.