• Title/Summary/Keyword: on-line measurement

Search Result 1,883, Processing Time 0.028 seconds

Research on Broadband Millimeter-wave Cascode Amplifier using MHEMT (MHEMT를 이용한 광대역 특성의 밀리미터파 Cascode 증폭기 연구)

  • Baek, Yong-Hyun;Lee, Sang-Jin;Baek, Tae-Jong;Choi, Seok-Gyu;Yoon, Jin-Seob;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.4
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, millimeter-wave broadband MHEMT (Metamorphic High Electron Mobility Transistor) cascode amplifiers were designed and fabricated. The $0.1{\mu}m$ InGaAs/InAlAs/GaAs MHEMT was fabricated for cascode amplifiers. The DC characteristics of MHEMT are 670 mA/mm of drain current density, 588 mS/mm of maximum transconductance. The current gain cut-off frequency($f_T$) is 139 GHz and the maximum oscillation frequency($f_{max}$) is 266 GHz. To prevent oscillation of the designed cascode amplifiers, a parallel resistor and capacitor were connected to the drain of common gate device. By using the CPW (Coplanar Waveguide) transmission line, the cascode amplifier was designed and matched for the broadband characteristics. The designed amplifier was fabricated by the MHEMT MMIC process that was developed through this research. As the results of measurement, the amplifier was obtained 3 dB bandwidth of 50.37 GHz between 20.76 to 71.13 GHz. Also, this amplifier represents the S21 gain with the average 7.07 dB gain in bandwidth and the maximum gain of 10.3 dB at 30 GHz.

Microstructure Evolution and Properties of Silicides Prepared by dc-sputtering (스퍼터링으로 제조된 니켈실리사이드의 미세구조 및 물성 연구)

  • An, Yeong-Suk;Song, O-Seong;Lee, Jin-U
    • Korean Journal of Materials Research
    • /
    • v.10 no.9
    • /
    • pp.601-606
    • /
    • 2000
  • Nickel mono-silicide(NiSi) shows no increase of resistivity as the line width decreases below 0.15$\mu\textrm{m}$. Furthermore, thin silicide can be made easily and restrain the redistribution of dopants, because NiSi in created through the reaction of one nickel atom and one silicon atom. Therefore, we investigated the deposition condition of Ni films, heat treatment condition and basic properties of NiSi films which are expected to be employed for sub-0.15$\mu\textrm{m}$ class devices. The nickel silicide film was deposited on the Si wafer by using a dc-magnetron sputter, then annealed at the temperature range of $150~1000^{\circ}C$. Surface roughness of each specimen was measured by using a SPM (scanning probe microscope). Microstructure and qualitative composition analysis were executed by a TEM-EDS(transmission electron microscope-energy dispersive x-ray spectroscope). Electrical properties of the materials at each annealing temperature were measured by a four-point probe. As the results of our study, we may conclude that; 1. SPM can be employed as a non-destructive process to monitor NiSi/NiSi$_2$ transformation. 2. For annealing temperature over $800^{\circ}C$, oxygen pressure $Po_2$ should be kept below $1.5{\times}10^{-11}torr$ to avoid oxidation of residual Ni. 3. NiSi to $NiSi_2$ transformation temperature in our study was $700^{\circ}C$ from the four-point probe measurement.

  • PDF

Design and Performance Evaluation of Two-Layered Microwave Absorbers(Dielectric/Magnetic) for Wide Oblique Incidence Angles Used for ITS (ITS용 2층형 전파 흡수체(유전체/자성체) 설계 및 경사 입사 흡수 특성 해석)

  • Kim, Jae-Woong;Kim, Sung-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1217-1223
    • /
    • 2007
  • Advanced microwave absorbers for wide oblique incidence angles are required in many applications including wireless communication or vehicle identification in ITS(Intelligent Transport System) where 5.8 GHz DSRC(Dedicated Short Range Communication) system is applied. In this study, two-layered microwave absorber(with a laminate structure of dielectric/magnetic composites) has been designed for the achievement of low reflection coefficient over wide incidence angles at 5.8 GHz. Iron flake particles are used as the filler in the absorbing layer, and the magnetic composite sheet exhibits high magnetic loss due to ferromagnetic resonance in gigahertz frequencies. The surface layer of low dielectric constant containing small amount of carbon black is used as the impedance transformer. On the basis of transmission line theory, the reflection loss has been calculated for the two-layer structure with variation of incident angles for both TE(Transverse Electric) and TM(Transverse Magnetic) polarizations. At the optimum thickness of the composite layers, a low value of reflection loss(less than -10 dB) has been predicted for wide incidence angles up to $55^{\circ}$ which is in good agreement with the measured value determined by free-space measurement.

Two-dimensional Velocity Measurements of Uvêrsbreen Glacier in Svalbard Using TerraSAR-X Offset Tracking Approach (TerraSAR-X 위성레이더 오프셋 트래킹 기법을 활용한 스발바르 Uvêrsbreen 빙하의 2차원 속도)

  • Baek, Won-Kyung;Jung, Hyung-Sup;Chae, Sung-Ho;Lee, Won-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.495-506
    • /
    • 2018
  • Global interest in climate change and sea level rise has led to active research on the velocities of glaciers. In studies about the velocity of glaciers, in-situ measurements can obtain the most accurate data but have limitations to acquire periodical or long-term data. Offset tracking using SAR is actively being used as an alternative of in-situ measurements. Offset tracking has a limitation in that the accuracy of observation is lower than that of other observational techniques, but it has been improved by recent studies. Recent studies in the $Uv{\hat{e}}rsbreen$ glacier area have shown that glacier altitudes decrease at a rate of 1.5 m/year. The glacier displacement velocities in this region are heavily influenced by climate change and can be important in monitoring and forecasting long-term climate change. However, there are few concrete examples of research in this area. In this study, we applied the improved offset tracking method to observe the two-dimensional velocity in the $Uv{\hat{e}}rsbreen$ glacier. As a result, it was confirmed that the glacier moved at a maximum rate of 133.7 m/year. The measruement precisions for azimuth and line-of-sight directions were 5.4 and 3.3 m/year respectively. These results will be utilized to study long-term changes in elevation of glaciers and to study environmental impacts due to climate change.

INTEGRATED RAY TRACING MODEL FOR END-TO-END PERFORMANCE VERIFICATION OF AMON-RA INSTRUMENT (AMON-RA 광학계를 활용한 통합적 광선 추적 기법의 지구 반사율 측정 성능 검증)

  • Lee, Jae-Min;Park, Won-Hyun;Ham, Sun-Jeong;Yi, Hyun-Su;Yoon, Jee-Yeon;Kim, Sug-Whan;Choi, Ki-Hyuk;Kim, Zeen-Chul;Lockwood, Mike
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • The international EARTHSHINE mission is to measure 1% anomaly of the Earth global albedo and total solar irradiance using Amon-Ra instrument around Lagrange point 1. We developed a new ray truing based integrated end-to-end simulation tool that overcomes the shortcomings of the existing end-to-end performance simulation techniques. We then studied the in-orbit radiometric performance of the breadboard Anon-Ra visible channel optical system. The TSI variation and the Earth albedo anomaly, reported elsewhere, were used as the key input variables in the simulation. The output flux at the instrument focal plane confirms that the integrated ray tracing based end-to-end science simulation delivers the correct level of incident power to the Amon-Ra instrument well within the required measurement error budget of better than ${\pm}0.28%$. Using the global angular distribution model (ADM), the incident flux is then used to estimate the Earth global albedo and the TSI variation, confirming the validity of the primary science cases at the L1 halo orbit. These results imply that the integrated end-to-end ray tracing technique, reported here, can serve as an effective and powerful building block of the on-line science analysis tool in support of the international EARTHSHINE mission currently being developed.

Solvent-Polymer Interactions for Stable Non-Aqueous Graphene Dispersions in the Presence of PVK-b-PVP Block Copolymer (PVK-b-PVP 블록 공중합체의 존재 하에서 안정한 비 수계 그래핀 분산액을 위한 용매-고분자 상호작용에 관한 연구)

  • Park, Kyung Tae;Perumal, Suguna;Lee, Hyang Moo;Kim, Young Hyun;Cheong, In Woo
    • Journal of Adhesion and Interface
    • /
    • v.18 no.3
    • /
    • pp.109-117
    • /
    • 2017
  • Poly(N-vinyl carbazole) (PVK) homopolymer, poly(4-vinylpyridine) (PVP) homopolymer, and PVK-b-PVP block copolymer were synthesized by reversible addition-fragmentation chain transfer (RAFT) polymerization and the polymers were used to prepare non-aqueous graphene dispersions with four different solvents, ethanol, N-methyl-2-pyrrolidone (NMP), dichloromethane (DCM), and tetrahydrofuran (THF). $^1H-$ and $^{13}C-NMR$ spectroscopy, size exclusion chromatography (SEC), and differential scanning calorimetry (DSC) were carried out to confirm the chemical structure of the polymers. Stability of graphene dispersions was measured by on-line turbidity measurement. Time-dependent Turbiscan Stability Index (TSI) values were interpreted in terms of surface tension (${\sigma}$) and solubility parameter (${\delta}$) among solvents, polymers, and graphene. It was confirmed that the solubilities of polymer and surface tension between solvent and graphene affected the dispersion stability of graphene. PVK-b-PVP block copolymer could effectively maintain the low TSI values of graphene dispersions in ethanol and THF, which have been known as poor solvents for graphene dispersions. It can also be noted that DCM shows good dispersion stability comparable to NMP, which has been known as the best solvent for graphene dispersion.

THE EFFECT OF THE LENGTH OF THE LINGUAL FRENUM AND THE TONGUE MOTION ON SPEECH (설소대의 크기와 운동이 발음에 미치는 영향)

  • Park, Seong-Hee;Son, Woo-Sung;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu;Chung, In-Kyo;Kwon, Soon-Bok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.6
    • /
    • pp.526-534
    • /
    • 2001
  • Purpose : The objective of this study is to ascertain whether the positive exists among the frenum length, the tongue movement and the speech and to present the normal range of tongue movement and guidelines for the choice of surgery, observation if necessary. Materials and Methods : 180 patients were evaluated. We divided 180 patients into 6 group by age. Each group was separated as follows; the age of 2.5-4, 5-6, 7-9, 10-12, 16-18. We measured the frenal length, the range of tongue motion and evaluated the speech so that we really questioned about the positive relationship between the tongue-tie and speech. We let the patient exercise the protrusive both(right, left) laterotrusive superior movement of the tongue. During these movements, we measured the distance between the vermilion border and the tongue tip. We also measured the distance from the tongue tip to the point contacting the upper lip with dorsum of the tongue during the maximal protrusive movement of the tongue. Three linear measurement of the anterior, inferior segment of the tongue including the lingual frenum, are made. These measurements are as follows: 1. Distance A. Free anterior portion of the tongue from the point of frenular insertion to the tongue tip. 2. Distance B. The distance from the initiating point of the lingual frenum to the point connecting the two sublingual carundcles to the lingual frenum perpendicularly. 3. Distance C. The distance from the point contacting the line crossing the sublingual caruncles with the lingual frenum to the terminating point of the lingual frenum. We transform three linear measures into a statistical ratio, A/(A-B+C), representing the length of the free portion of the tongue compared with the total sublingual dimensions. In addition, we assessed the speech through Picture Consonant Articulation Test(PCAT) and tried to find out the relationship between the length of the lingual frenum and speech. Conclusion : As people are born, they have small and restricted tongue. As people grow old, tongue motions are more liberate, and unrestricted and they can speak so freely. Therefore we suggest that until age 5, oral and maxillofacial surgeons postpone the surgery if not urgent, evaluate the maximal lingual motions and PCAT according to this article and observe their changes.

  • PDF

Korean Strategies for Establishing New MRV Schemes Applicable to Post-2020 Regime (Post-2020의 MRV 체계 수립을 위한 우리나라 대응 방향)

  • Kim, Seungdo;Ryu, SeungYun;Jung, Jaehyuk;Yoo, Beom-Sik
    • Journal of Environmental Policy
    • /
    • v.14 no.4
    • /
    • pp.3-21
    • /
    • 2015
  • This paper attempts to determine the most reasonable and agreeable option for new MRV framework in Post-2020 Climate Regime as well as to develop South Korea strategies to reflect our national circumstances and capacities appropriately. The options for MRV framework considered here are 1) Dual MRV and 2) Unified MRV. We reached the conclusion that the Unified MRV framework may be the most reasonable option in the 2015 agreement in line with the objectives of MRV. To this end, it is essential to develop effective stepwise strategies consisted of: 1) reaching a consensus internally on the Unified MRV framework, 2) developing detailed procedures and methodologies to make the major elements of the Unified MRV framework understandable and predictable, 3) delivering an overview and blueprint to make sure of the flexibility of the Unified MRV framework to reflect the Parties' capacities and national circumstances, 4) ensuring the financial and technical support schemes for developing countries to improve the capacity-buildings of MRV, and 5) developing a realistic road map to successfully implement the Unified MRV scheme within the required time frame. Korea, as a rational mediator between developed and developing countries, should play a leading role in reaching post-2020 agreement.

  • PDF

The Evaluation of Soft and Hard Tissue Change for Retraction of Lower Anterior Tooth in Bimaxillary Protrusion Patients according to Two Different Therapeutic Methods: Mandibular Anterior Segmental Osteotomy and Orthodontic Treatment with Teeth Extraction (양악전돌증 환자에서 하악 6전치 후방 이동 시 치료 방법에 따른 하악 경조직과 연조직의 변화: 하악 전방분절골절단술과 발치 교정 치료)

  • Kim, Young-Joo;Kim, Kyung-A;Yu, Yong-Jae;Ryu, Kyung-Sun;Ryu, Jeong-Min;Ohe, Joo-Young;Kim, Su-Jung;Kim, Seoung-Hun;Lee, Baek-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.246-251
    • /
    • 2012
  • Purpose: The purpose of the study is to evaluate the effectiveness of anterior segmental osteotomy (ASO) in bimaxillary protrusion (BP) patients by comparison between the mandibular soft and hard tissue changes from orthodontic treatment and ASO. Methods: All 44 patients were diagnosed with BP in Kyung-Hee Medical Center. Orthodontic treatment with teeth extractions were underwent by 23 patients (Group A) and 21 patients underwent ASO (Group B). Mandibular soft and hard tissue changes were measured and evaluated, which were based on the vertical and horizontal reference line in lateral cephalometric radiographs. Statistical significance between the changes and correlation between each measurement were analyzed. Results: The amount of B point movement was lesser than that of the lower incisal tip (LIT) retraction, and LIT was tilted lingually in group A. The posterior movement discrepancy between LIT and B point was insignificant, and the inclination of lower incisor was not changed in group B. The soft tissues, including the lower lip, showed a posterior movement and reduction in the depth of mento-labial groove. According to the correlation analysis, the movement of the lower incisor was significantly related to the movement of the lower lip in group A, and the movement of the lower incisor was significantly related to that of the movement of lower lip, B point and Pog in group B. Conclusion: The orthodontic treatment in BP patients results in posterior tilting movement of the lower incisor, but ASO results in the bodily movement of the lower incisor. Consequently, ASO is more effective in BP cases because it ensures the controlled movement of the lower incisors.

Comparison of Mechanical and Interfacial Properties on Chemical Structures of Acrylic and Epoxy Adhesives (아크릴 및 에폭시 접착제의 화학적 구조에 따른 유리섬유 복합재료의 기계적 및 계면 물성 변화 평가)

  • Shin, Pyeong-Su;Kim, Jong-Hyun;Choi, Jin-Yeong;Kwon, Dong-Jun;Lee, Sang-Il;Park, Joung-Man
    • Composites Research
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2016
  • An adhesive can be used to connect two different materials in structures. In comparing with other connecting methods, such as bolt, rivet, and hot melting, the adhesive does not need to use them. It leads to reduce the weight and decrease the stress concentration along the connecting line. This work studied the comparison of mechanical and interfacial properties of commonly-used two adhesives, acrylic type and bisphenol-A epoxy type. Tensile and flexural strength of neat adhesives were also compared. Lap shear test of two adhesives was deduced from the measurement of tensile and fatigue tests. After testing, the failure patterns of adhesive surfaces were observed by a microscope. Tensile strength and mechanical fatigue resistance at using bisphenol-A epoxy adhesive were better than acrylic adhesive. Also adding CNT reinforcement in epoxy adhesive can anticipate mechanical improvement.