• Title/Summary/Keyword: on-line measurement

Search Result 1,876, Processing Time 0.032 seconds

Implementation of an Automated In-line Water Quality Measurement System of Recirculation Fish Farm with IoT (IoT에 의한 순환여과식 양식장 자동 수질 측정 시스템 구현)

  • Kim, Sun-Woo;Choi, Yeon-Sung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.3
    • /
    • pp.477-484
    • /
    • 2017
  • In the conventional recirculation fish farms, there is a lot of difficulties due to lack of professional manpower and high reliance on imported measurement equipment. In this paper, we implement an automatic water quality measurement system which can measure the pollution degree in a water tank of fish farms using an optical sensor(pH, DO) with the IoT technology. The problem with existing systems is that the fish tank should be checked by means of human, or put the measuring equipment into the water tank of fish farms and measurement directly. But, it has a bad influence on the growth of fish. In this paper, we propose a method of indirect measurement without immersing the measurement equipment in a water tank of fish farm and develop a sustainable measurement system in an environment containing salt and lots of pollutants without affecting the growth of fish within the water tank of fish farms.

A Study on Mechanical Measurement of Motor and Transformer for Korean High-Speed Train

  • Han, Young-Jae;Kim, Seog-Won;Seo, Sung-Il;Kim, Young-Guk;Park, Choon-Soo;Lee, Su-Gil;Kim, Jong-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1720-1723
    • /
    • 2003
  • Recently, as the road capacity reaches a limit and environmental problems becomes serious, there exists a gradually increased need for railway vehicles that are environment-friendly, punctual, reliable and safe. Accordingly, in addition to conventional railroad vehicles, lots of vehicles are being newly developed. Korean High Speed Train has been developed for last 6 years to satisfy the need. Authors developed a measurement system for on-line test and evaluation of performances of Korean High-Speed Train. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the measurement system. By using the system, measurement and evaluation of the mechanical characteristics of motors and main transformers in Korean High Speed Train was conducted during test running. The measured results for the temperature characteristics of electric devices verify that the measurement system is accurate and reliable.

  • PDF

A Study on Automated Outer Diameter Measurement System for Axisymmetric Automotive Part (자동차용 축대칭 형상 부품 외경 자동측정시스템에 관한 연구)

  • Ban, Kap-Soo;Bae, Jun-Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.3
    • /
    • pp.61-68
    • /
    • 2013
  • Automatic measurement system is required since cycle time and cost of production are increased by various factors in manual systems. This paper presents a machine vision based prototype measurement system for the automotive axisymmetric shape parts which are generally measured by a manual system that is required the tolerance of the part is very small on each machined surface. This measurement system adopts a method in which optical lens is transferred along the profile of the part to minimize measurement cycle time. The main interest of this paper is a development of an optimum measurement algorithm to the outside diameter of the parts that can be applied to various combinations of hardware. The operating system used to implement the whole system is Window XP and corresponding environment.

On-line Conversion Estimation for Solvent-free Enzymatic Esterification System with Water Activity Control

  • Lee, Sun-Bok;Keehoon Won
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.2
    • /
    • pp.76-84
    • /
    • 2002
  • On-line conversion estimation of enzymatic esterification reactions in solvent-free media was investigated. In principle, conversion to ester can be determined from the amount of water produced by the reaction, because water is formed as a by-product in a stoichiometric manner. In this study, we estimated the water production rate only from some measurements of relative humidity and water balances without using any analytical methods. In order to test the performance of the on-line conversion estimation, the lipase-catalyzed esterification of n-capric acid and n-decal alcohol in solvent-free media was performed whilst controlling water activity at various values. The reaction conversions estimated on-line were similar to those determined by offline gas chromatographic analysis. However, when the water activity was controlled at higher values, discrepancies between the estimated conversion values and the measured values became significant. The deviation was found to be due to the inaccurate measurement of the water content in the reaction medium during the initial stages of the reaction. Using a digital filter, we were able to improve the accuracy of the on-line conversion estimation method considerably. Despite the simplicity of this method, the on-line estimated conversions were in good agreement with the off-line measured values.

A Study on Curvature Radius Measurement Using Laser Interferometer (레이저 간섭계를 이용한 곡률반경 측정에 관한 연구)

  • Lee Ji Yong;Kim Min Ju;Lee Seung Soo;Jeon Eon Chan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.34-40
    • /
    • 2004
  • This paper presents studies on curvature radius measurement using the laser interferometer. It is a general practice to measure to $10^{-10}$m in length with the recent improvement and innovations in measurement technology and the processor used. The measurement methods can generally be categorized as these two: the contactual method and non-contactual method; and in this study, we will find ways to lower the cost for a CMM, or a coordinate measurement machine, and try to find an alternative. Furthermore, we will discuss some of the ways to improve the non-contactual measurement methods-optical interferometer method and the optical triangulation method. We will measure an object using a laser distance measuring device and Set the Point-contact result with the ball-bearing type and line-contact result with the bearing type, to decide on which probe type will be used.

A Reduced Equivalent Line Constant of the Catenary System (전차선로 시스템의 축약 등가 선로정수에 관한 연구)

  • 이한민;오광해;이장무;박현준;장길수;권세혁
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.421-431
    • /
    • 2004
  • Line constants are composed by impedances and susceptances. A paper which was published estimated only impedances of line constants. Therefore, this paper estimates susceptances as well as impedances of equivalent five-conductors model using the reduced equivalent method. In order to verify estimated line constants, we measured line constants of real railway system. And we compared calculated results with measured data on 60Hz∼3000Hz. For the other verification, the calculation results from the proposed model and the measurement data from the test are compared focused on the amplification of harmonic current in the paper.

A Study on Performance Characteristics for Auxiliary Converter of Korean High Speed Train (한국형 고속열차 보조컨버터 성능 특성에 관한 연구)

  • Han, Young-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.247-249
    • /
    • 2006
  • As the on-board electric devices determine the performances of vehicles, production of reliable devices is important. To keep the reliability of devices constant, management of performance evaluation of the on-board devices is crucial. Because temperature bas a serious effect on failures of the components of the devices, its measurement is the first step for good management. In this study, we described performance characteristics of domestic auxiliary block developed through G7 project. We measured the performances of auxiliary block during test running by the developed on-line measurement system. After we save the input real-time data from each signal of Korean High Speed Train through the network line, we can acquire necessary information through Post-Processing program. We verify the auxiliary converter characteristics of Korean High Speed Train by this system.

  • PDF

A study on the temperature distribution measurement of the high pressure mercury lamp (고압 수은등의 온도분포 측정에 대한 연구)

  • 손승현;김상용;김창섭;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.35-40
    • /
    • 1990
  • Temperature distribution of high pressure mercury lamp has been mesured as a function of time using spectroscopic method. Sampling signal which is synchronized by lamp voltage was used to mesure temporal line intensity at each radius. To obtain radial temprature distribution, the mesured intensity was transformed into radial line intensity by Abel's formula. Absolute temperature profile was calculater from relative intensities of spectral lines as a function of line and tube radius. The temperature profile is very similar to the electrical tube current profile.

  • PDF

Stress Evaluation by the Measurement of Acoustoelastic Effect Using a Line-Foucus Acoustic Microscope (선 집속 초음파 현미경을 이용한 음탄성효과 측정에 의한 응력 평가)

  • Kim, J.O.;Lee, Y.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.119-126
    • /
    • 1997
  • The relationship between the applied stresses and the change of elastic wave velocity has been established based on the acoustoelasticity theory. The non-uniform stress field in a loaded specimen has been evaluated from the surface acoustic wave velocity measured by the line-focus acoustic microscopy with the acoustoelastic constants obtained form a calibration test. The evaluated stresses are in good agreement with the results calculated by finite element method.

  • PDF

A Study on the Crotch Length for Dance Movement (무용동작을 위한 밑위길이에 관한 연구)

  • Yoon, Sung-Hwa;Lee, Young-Ju
    • Korean Journal of Human Ecology
    • /
    • v.11 no.1
    • /
    • pp.45-58
    • /
    • 2002
  • The purpose of this study was to offer a more functional slacks by analyzing its crotch length. The result of the study were as follows : Regarding the feeling of wearing and appearance, the P2 b style which measures the crotch length starting from the waist line passing around the iliac spine was the most highly evaluated. This suggested that the functionality of dance movement was more influenced by the position of the waist line not by the crotch length measurement. Since the front and rear center lines of the crotch could not be flown if the waist line of slacks was positioned high, both the crotch and abdominal part might be clogged or tightened when dancers made large dance movements or bended their upper bodies forward. In conclusion, slacks for more functional dance movement should be manufactured focusing on the location of the waist line rather than on the crotch length.

  • PDF