• Title/Summary/Keyword: on-line diagnosis system

Search Result 263, Processing Time 0.029 seconds

Diagnosis of power cable system based on the HFPD detection at on-site (HFPD 검출법을 이용한 지중 케이블 실선로 진단)

  • Lee, J.S.;Kim, C.S.;Lee, D.G.;Kong, C.H.;Seok, K.H.;Lee, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.97-100
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnosis of cable system in the world although Korea just begin. The efficiency of measurement has been reported and proved by many researchers who are engaged in the diagnosis of high power apparatus. LG Cable has investigated the technology of diagnosis for cable system by means of PD measurement for 10 years. In this paper, PD measurement with portable device was performed to evaluate the quality of the 154kV transmission line and the 22.9kV XLPE cable line. Test results are shown that the HFPD detection technology is very attractive for the diagnosis of power cable system by high detection sensitivity at on-site.

  • PDF

On-line fault diagnosis of a distillation column using time-delay neural network (Time-Delay Neural Network를 이용한 증류탑의 on-line 고장 진단)

  • 이상규;박선원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.1109-1114
    • /
    • 1992
  • Modern chemical processes are becoming more complicated. The sophisticated chemical processes have needed the fault diagnosis pxpert systems that can detect and diagnose the fault diagnosis expert systems that can detect and diagnose the faults of some processes and give and advice to the operator in the event of process faults. We present the Time-Delay Neural Network(TDNN) approach for on-line fautl diagnosis. The on-line fault diagnosis system finds the exact origin of the fault of which the symptom is propagated continuously with time. The proposed method has been applied to a pilot distillation column to show the merits and applicability of the TDNN.

  • PDF

Development of Insulation Diagnosis System by On-Line Partial Discharge Measurement of Generator Stator Windings (발전기 고정자 권선의 운전중 부분방전 측정에 의한 절연진단 시스템 개발)

  • Shin, Byoung-Chol;Hwang, Don-Ha;Kim, Yong-Joo;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1025-1027
    • /
    • 1999
  • Recently, many researches on a diagnosis of stator winding insulation of large generators are reported. They mostly utilize a trend analysis of Partial Discharge (PD). In this paper, a novel on-line monitoring system for an insulation diagnosis is proposed. This system obtains the parameters such as Maximum Partial Discharge Magnitude (QM), Normalized Quantity Number (NQN) and Dynamic Stagnation Voltage (DSV) by continuous on-line monitoring of winding insulation. It is capable of diagnosing the insulation condition by analyzing the trend of PD and utilizing the database built by the system.

  • PDF

A Study on Remote ECG Diagnostic System Using Telephone Line (공중회선망을 이용한 원격 심전도 진단 시스템)

  • Lee, M.H.;Park, S.H.;Kim, Y.M.;Shin, K.S.;Jeong, H.K.;Jeong, K.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.69-78
    • /
    • 1992
  • This Paper describes implementation of a remote ECG diagnostic system using telephone line. The overall system includes ECG data acquisition system, ECG terminal, system control software, automatic diagnosis system, and transmission system.'The proposed system provides various functions, which are ECG data acquisition, transmission, receiving, diagnosis and dialogue between patients and medical doctors. Thls system is very simple and convienient to use. We evaluate the performance of modem and the accuracy of automatic diagnosis algorithm. The obtained results suggest the Possibilities of a remote ECG diagnostic system using the only existed telephone line.

  • PDF

Fault Diagnostic System Based on Fuzzy Time Cognitive Map

  • Lee, Kee-Sang;Kim, Sung-Ho
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.1 no.1
    • /
    • pp.62-68
    • /
    • 1999
  • FCM(Fuzzy Cognitive Map) is proposed for representing causal reasoning. Its structure allows systematic causal reasoning through a forward inference. Authors have already proposed a diagnostic system based on FCM to utilized to identify the true origin of fault by on-line pattern diagnosis. In FCM based fault diagnosis, Temporal Associative Memories (TAM) recall of FCM is utilized to identify the true origin of fault by on-line pattern match where predicted pattern sequences obtained from TAM recall of fault FCM models are compared with actually observed ones. In engineering processes, the propagation delays are induced by the dynamics of processes and may vary with variables involved. However, disregarding such propagation delays in FCM-based fault diagnosis may lead to erroneous diagnostic results. To solve the problem, a concept of FTCM(Fuzzy Time Cognitive Map) is introduced into FCM-based fault diagnosis in this work. Expecially, translation method of FTCM makes it possible to diagnose the fault for some discrete time. Simulation studies through two-tank system is carried out to verify the effectiveness of the proposed diagnostic scheme.

  • PDF

Auto-Generation of Diagnosis Program of PLC-based Automobile Body Assembly Line for Safety Monitoring (PLC기반 차체조립라인의 안전감시를 위한 진단프로그램 생성에 관한 연구)

  • Park, Chang-Mok
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.65-73
    • /
    • 2010
  • In an automated industry PLC plays a central role to control the manufacturing system. Therefore, fault free operation of PLC controlled manufacturing system is essential in order to maximize a firm's productivity. On the contrary, distributed nature of manufacturing system and growing complexity of the PLC programs presented a challenging task of designing a rapid fault finding system for an uninterrupted process operation. Hence, designing an intelligent monitoring, and diagnosis system is needed for smooth functioning of the operation process. In this paper, we propose a method to continuously acquire a stream of PLC signal data from the normal operational PLC-based manufacturing system and to generate diagnosis model from the observed PLC signal data. Consequently, the generated diagnosis model is used for distinguish the possible abnormalities of manufacturing system. To verify the proposed method, we provided a suitable case study of an assembly line.

A Operating Status Diagnosis of DC/DC Converter by System Identification (System Identification Method를 이용한 DC/DC 컨버터 상태진단)

  • Kim, Cheul-U;Kim, Tae-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.724-729
    • /
    • 2007
  • In this paper, we propose a new diagnosis method of DC/DC converter aging. The method is based on variations of the parasitic resistor for the aging process. We apply an on-line diagnosis of the DC/DC converter because the observation is not a device, but a system. This study proposes a method of DC/DC converter diagnosis by analyzing the variations of model on the variations of parasitic resistor.

A case study on the failure diagnosis of plant machinery system by implementing on-line wear monitoring (실시간 마모량 측정을 통한 대형 기계윤활시스템의 파손발생 진단사례)

  • 윤의성;장래혁;공호성;한흥구;권오관;송재수;김재덕;엄형섭
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.321-327
    • /
    • 1998
  • This paper presented a case study on the application of on-line wear monitoring technique to a high duty air-turbo-compressor system. Main objects monitored were a gear unit and metal bearings, both shown frequent troubles due to the severe operation conditions at heavy dynamic load. The air-turbo-compressor system needs secure condition monitoring because it is one of the main utilities in steel making industry. Temperature and vibration characteristics have been mainly on-line monitored in this system for a predictive maintenance; however, it has been shown that they are not fairly good enough to give an early warning prior to the machine failure. In this work, an on-line Opto Magnetic Detector(OMD) was implemented for an on-line wear monitoring, which quantitatively measured the contamination level of both ferrous and non-ferrous wear particles by detecting the change in optical density of used oil. Results showed that the application of on-line OMD system was satisfactory in diagnosis of the machine system.

  • PDF

A Diagnosis Scheme of Switching Devices under Open Fault in Inverter-Fed Interior Permanent Magnet Synchronous Motor Drive (매입형 영구자석 동기전동기 구동용 인버터 스위칭 소자의 개방 고장 진단)

  • Choi, Dong-Uk;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.61-68
    • /
    • 2012
  • This paper deals with a fault diagnosis algorithm for open faults in the switching devices of PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive. The proposed diagnostic algorithm is realized in the controller using the informations of three-phase currents or reference line-to-line voltages, without requiring additional equipments for fault detection. Under switch open fault conditions, the conventional dq model used to control an AC motor cannot directly be applied for the analysis of drive system, since three-phase balanced condition does not hold. To overcome this limitation, a fault model based on the line-to-line voltages is employed for the simulation studies. For comparative performance evaluation through the experiments, the entire control system is implemented using digital signal processor (DSP) TMS320F28335. Simulations and experimental results are presented to verify the validity of the proposed diagnosis algorithm.

Development of Continuous Monitoring System for Generator Stator Insulations (발전기 고정자 권선 절연상태의 상시 감시 시스템 개발)

  • Shin, Byoung-Chol;Hwang, Don-Ha;Kim, Yong-Joo;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2212-2214
    • /
    • 1999
  • In this paper, a novel Generator On-line Diagnosis System (GODS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, such as SSC (Stator Slot Coupler) and RFCT (Radio Frequency Current Transformer) are used for PD measurement. PD signals are continuously measured and digitized with a high speed A/D converter to build the database of the generator's insulation condition. Also this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF