• 제목/요약/키워드: on-line diagnosis system

검색결과 263건 처리시간 0.025초

회전기 고정자 권선에서의 운전 중 절연열화 진단기법 (On-Line Insulation Diagnosis Techniques for Stator Winding of Rotating Machines)

  • 윤대희;황돈하;신병철;김용주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.89-93
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines. And a novel on-line monitoring system for an insulation diagnosis is proposed.

  • PDF

저압 배선 이상 진단을 위한 지능형 차단 시스템 구축 (Development Intelligent Diagnosis System for Detecting Fault of Transmission Line)

  • 성화창;박진배;주영훈
    • 한국지능시스템학회논문지
    • /
    • 제18권4호
    • /
    • pp.518-523
    • /
    • 2008
  • 본 논문에서는 저압 배선 진단 시스템 개발에서 핵심 파트 중 하나인 지능형 차단 시스템 구축을 목표로 한다. 제안된 진단 시스템은 TFDR (Time-Frequency Domain Reflectometry) 알고리즘을 바탕으로 하여 실제 전압이 흐르는 배선에 대해 이상 거리 측정을 하게 된다. 그리고 배선으로부터 얻은 정보를 바탕으로 배선 이상의 종류를 분석하는 것이 지능형 차단 시스템의 목표이다. 효율적인 분석을 위해, 본 논문에서는 퍼지-베이시안 (Fuzzy-Bayesian) 알고리즘을 바탕으로 하여 시스템을 구성하였다. 실제 저압 배선에서 실험된 데이터를 바탕으로 한 실험을 통해 제안된 기술의 우수성을 입증하고자 한다.

발전기 회전자 권선의 층간단락 진단시스템 개발 (Development of Shorted-Turn Diagnosis system for Generator Rotor Winding)

  • 이영준;김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.742-747
    • /
    • 1999
  • On-line diagnosis system has been developed and is now applied the detection of shorted turns in the field winding of large generator. This system consists of data aquisition system and display PC. The data aquisition system detects voltage waveforms from flux probe sensor installed in the stator slot. The display PC shows theshorted-turn situation of generator rotor winding. A shorted-turn diagnosis test wasperformed on five gas turbine generators at the Seoinchon combined cycle power plant. The test was conducted using an new diagnosis system and digital oscilloscope which can identify the pole location, the slot number and the number of shorted turns within each slot. It is confirmed that results of two systems are very same in the field tests.

  • PDF

Parameter Estimation by OE model of DC-DC Converter System for Operating Status Diagnosis

  • Jeon, Jin-Hong;Kim, Tae-Jin;Kim, Kwang-Su;Kim, Kwang-Hwa
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권4호
    • /
    • pp.206-210
    • /
    • 2004
  • This paper deals with a parameter estimation of the DC-DC converter system for its diagnosis. Especially, we present the results of parameter estimation for the DC-DC converter model by the system identification method. The parameter estimation for the DC-DC converter system aims at the diagnosis of its operating status. For the operating status diagnosis of the DC-DC converter system, we assume that the DC-DC converter system is an equivalent model of the Buck converter and estimate the main parameter for on-line diagnosis. In addition, for verification of an estimated parameter, we compare a bode plot of the estimated system transfer function and measurement results of the HP4194 instrument. It is a control system analyzer for system transfer function measurement. Our results confirm that the main parameter for diagnosis of the DC-DC converter system can be estimated by the system identification method and that the aging status of the system can be predicted by these results on operating status.

전기설비사고예방을 위한 온라인진단기술 개발의 경제성 분석 (A Study on Economic Analysis of Development of On-line Diagnosis Technique for Preventing Electrical Accidents)

  • 김한상;김광호
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.313-318
    • /
    • 2014
  • In the last couple of decades industrialization and technological development has not only increase in the scale of electrical facilities and it has become more and more complicated and diversified. Furthermore, fires in the electrical transformers, like those that have knocked out power in the country in the past years, are likely to become more common as utility systems begin to show their age. The importance of preventing electrical accidents can never be overemphasized and for this reason, supply of on-line diagnosis system combining information and communication technology(ICT) for the customer's electrical facilities has been increasing recently. The major advantage of on-line diagnosis system is that the device's potential problems could be detected early before a serious deterioration or breakdown occurs. In this paper, We estimated the benefit from the investment in the right of present value of sales, success rate of commercialization regarding R&D investment for development and commercialization of on-line diagnosis technology targeting customer electrical facilities. As a result, the net value added of 29.7 billion won and the increased profit by roughly 7.52 precent are expected.

공조설비용 고장진단시스템의 실시간 진단실험 (The On-Line Diagnostic Test of Fault Diagnosis System for Air Handling Unit)

  • 소정훈;유승신;경남호;신기석
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.787-795
    • /
    • 2001
  • An experimentation on the on-line fault detection and diagnosis(FDD) system has been performed with HVAC system in he experimental building constructed inside the large scale environmental chamber. Personal computer with a home-made FDD program by pattern recognition method utilizing artificial neural network was connected on-line via Ether-net TCP/IP to the supervisory control server for HVAC system. The FDD program monitored the HVAC system by 1 minuted interval. The results showed that he FDD program detected the sudden or abrupt faults such s those in fans, sensors and heater, etc.

  • PDF

고압 회전기 고정자 권선의 절연진단을 위한 중앙 집중 감시 시스템 개발 (Development of Central Monitoring System for Insulation Diagnosis of High-Voltage Generator/Motor Stator Windings)

  • 신병철;윤대회;황돈하;김용주;주영호;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1906-1908
    • /
    • 2000
  • The central monitoring system with on-line diagnosis of high-voltage generator/motor stator insulation is developed. The system is capable of remote diagnosis and monitoring partial discharges of high-voltage generator/motor stator insulation. GOMS(Generator On-line Monitoring System) with maximum of 9 input channels can measure and analyze the status of high-voltage motor stator insulation by on-line. The measured and analysis data are brought to the central monitoring system via modem to build database. The central monitoring system can diagnose and monitor the insulation status of several high-voltage generator/motor at any time. The insulation status of those machines can be enhanced by the database on partial discharges.

  • PDF

전력계통 사고구간 판정을 위한 Commectionist Expert System (A Connectionist Expert System for Fault Diagnosis of Power System)

  • 김광호;박종근
    • 대한전기학회논문지
    • /
    • 제41권4호
    • /
    • pp.331-338
    • /
    • 1992
  • The application of Connectionist expert system using neural network to fault diagnosis of power system is presented and compared with rule-based expert system. Also, the merits of Connectionist model using neural network is presented. In this paper, the neural network for fault diagnosis is hierarchically composed by 3 neural network classes. The whole power system is divided into subsystems, the neural networks (Class II) which take charge of each subsystem and the neural network (Class III) which connects subsystems are composed. Every section of power system is classified into one of the typical sections which can be applied with same diagnosis rules, as line-section, bus-section, transformer-section. For each typical section, only one neural network (Class I) is composed. As the proposed model has hierarchical structure, the great reduction of learning structure is achieved. With parallel distributed processing, we show the possibility of on-line fault diagnosis.

  • PDF

발전기 고정자 권선의 운전중 부분방전 모니터링 시스템 개발 (Continuous On-Line Partial Discharge Monitoring System for Stator Winding of Generators)

  • 전정우;황돈하;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1734-1736
    • /
    • 1998
  • On-line partial discharge monitoring system for generator stator insulation is developed. This system consists of remote and host units. The remote unit detects partial discharge signals from SSC(Stator Slot Coupler) installed between wedge and stator windings. The host unit monitors the condition of winding insulation. This system will be used as a module of a generator on-line monitoring system utilizing global network.

  • PDF