• Title/Summary/Keyword: on-line diagnosis system

Search Result 263, Processing Time 0.028 seconds

Development of Expert System to Diagnose and Monitor 765KV Power Apparatus in On-line Condition (765KV 변전설비 운전중 상태감시 및 진단을 위한 전문가시스템 개발)

  • Jeong, Gil-Jo;Choe, In-Hyeok;Kim, Gwang-Hwa;Gwak, Hui-Ro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.11
    • /
    • pp.562-568
    • /
    • 2001
  • In this paper, we described the export system to monitor and diagnose 765KV power apparatus. To develop this expert system, we studied the knowledge bases and data bases for 765KV transformer and GIS. In order to make the reliable inference of knowledge base and the good MMI(Man Machine Interface), the data bases were consisted of the tables of power apparatus information, limit level value, measured input data, inference result and diagnosis result. The knowledge base had various rules to infer the conditions of transformer and GIS. We applied both the forward chaining and backward chaining methods to these rules of system for good inferences. This paper describes the applied methods for expert system. Also, this developed system was tested with dissolved gas analyzing result and the result was shown.

  • PDF

Microdevice for Separation of Circulating Tumor Cells Using Embedded Magnetophoresis with V-shaped Ni-Co Nanowires and Immuno-nanomagnetic Beads

  • Park, Jeong Won;Lee, Nae-Rym;Cho, Sung Mok;Jung, Moon Youn;Ihm, Chunhwa;Lee, Dae-Sik
    • ETRI Journal
    • /
    • v.37 no.2
    • /
    • pp.233-240
    • /
    • 2015
  • The novelty of this study resides in a 6"-wafer-level microfabrication protocol for a microdevice with a fluidic control system for the separation of circulating tumor cells (CTCs) from human whole blood cells. The microdevice utilizes a lateral magnetophoresis method based on immunomagnetic nanobeads with anti-epithelial cell adhesive molecule antibodies that selectively bind to epithelial cancer cells. The device consists of a top polydimethylsiloxane substrate for microfluidic control and a bottom substrate for lateral magnetophoretic force generation with embedded v-shaped soft magnetic microwires. The microdevice can isolate about 93% of the spiked cancer cells (MCF-7, a breast cancer cell line) at a flow rate of 40/100 mL/min with respect to a whole human blood/buffer solution. For all isolation, it takes only 10 min to process 400 mL of whole human blood. The fabrication method is sufficiently simple and easy, allowing the microdevice to be a mass-producible clinical tool for cancer diagnosis, prognosis, and personalized medicine.

Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring (SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발)

  • Ha, B.N.;Lee, S.W.;Shin, C.H.;Seo, I.Y.;Jang, Mun-Jong;Park, M.H.;Yun, G.G.;Song, I.K.;Lee, B.S.;Lee, J.C.;NamKoong, W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

Constitutional Classification between Tae-eumin and Soyangin Types by Measurement of the Friction Coefficient on the Skin of the Human Hand (손등 피부 마찰계수를 이용한 태음인과 소양인 간의 체질구별)

  • Song, Han-Wook;Park, Yon-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.52-61
    • /
    • 2010
  • The use of the friction coefficient is known to provide good discrimination ability in the classification of human constitutions, which are used in alternative medicine. In this study, a system that uses a multi-axis load cell and a hemi-circular probe is designed. The equipment consists of a sensor (load cell type, manufactured by the authors), an x-axis linear-bush guide motorized mobile stage that supports the hand being analyzed, and a signal conditioner. Using the proposed system, the friction coefficients from different constitutions were compared, and the relative repeatability error for the friction coefficient measurement was determined to be less than 2 %. The direction along the ring finger line was determined to be the optimum measurement region for a constitutional diagnosis between Tae-eumin and Soyangin types using the proposed system. There were some differences in the friction coefficient between the two constitutions, as reported in ancient literature. The proposed system is applicable to a quantitative constitutional diagnosis between Tae-eumin and Soyangin types within an acceptable level of uncertainty.

Incorporating Performance Degradation in Fault Tolerant Control System Design with Multiple Actuator Failures

  • Zhang, Youmin;Jiang, Jin;Theilliol, Didier
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.3
    • /
    • pp.327-338
    • /
    • 2008
  • A fault tolerant control system design technique has been proposed and analyzed for managing performance degradation in the presence of multiple faults in actuators. The method is based on a control structure with a model reference reconfigurable control design in an inner loop and command input adjustment in an outer loop. The reduced dynamic performance requirements in the presence of different actuator faults are accounted for through different performance reduced (degraded) reference models. The degraded steady-state performances are governed by the reduced levels of command input. The reconfigurable controller is designed on-line automatically in an explicit model reference control framework so that the dynamics of the closed-loop system follow that of the performance reduced reference model under each fault condition. The reduced command input level is determined to prevent potential actuator saturation. The proposed method has been evaluated and analyzed using an aircraft example against actuator faults subject to constraints on the magnitude and slew-rate of actuators.

A Study on Diagnosis of The Energized Status of 22.9kV Multigrounded Underground Power Cable (22.9kV 다중 접지 지중 전력 케이블의 가압 상태 진단에 관한 기초 연구)

  • Kim, Chang-Gyo;Hong, Jin-Su;Jeong, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.699-703
    • /
    • 1999
  • An experimental study to identify the energized status of the 22.9kV underground power cable by the detection of vibration has been performed. We have derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The relative amplitudes of the cable vibration according to the energized status of the cable were calculated by computer simulation. The cable vibration can also be picked up by accelerometer. A prototype was tested on the underground distribution system in Chonan substation, KEPCO. Comparison between simulation results and field test results was performed. The results showed that the energized status of the calble can be identified by measuring the vibration of the cable using accelerometer.

  • PDF

The Oriental and Western Medical Study of Fracture (골절(骨折)에 대한 동서의학적(東西醫學的) 고찰(考察))

  • Yim, Chang-Bum;Kim, Youn-Jin;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.16 no.1
    • /
    • pp.157-166
    • /
    • 2007
  • Objectives : The purpose of this study is to search for more effective methods of diagnosis and treatment of Fracture. Methods : Literature review on Fracture in view of oriental and western medicine. Conclusions : Fracture is classified by anatomical location, grade, shape of line, displacement and cause. The symptom of Fracture is pain, tenderness, deformity, attitude, abnormal mobility, crepitus, neurovascular injury. Fracture is not the same in Healing process by location. The age, endocrine system, chronic debilitating disease, stabilization is effect on healing period and process. Treatment of Fracture is classified emergency care, definite treatment and rehabilitation.

  • PDF

Sensitivity Enhancement in Measurement of Hydrogen Gas Dissolved in Oil using Gas Collection Time (가스수집시간을 이용한 유중수소가스 측정감도 향상 연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.539-543
    • /
    • 2009
  • This paper describes the sensitivity enhancement in measurement of the hydrogen gas dissolved in oil using gas collection time. On-line gas measurement is a useful for continuous monitoring of power transformer. Recently many studies on hydrogen gas measurement, due to their simplicity and low price, have been done for transformer monitoring. In measurement of the hydrogen gas in oil, the suitable sensitivity and resolution in the desired ranges of the gas concentrations are needed for the reliable monitoring of power transformers. In this study, the sensor output trends were analyzed with the hydrogen gas collection time which means the time to collect the hydrogen gas before reaction of hydrogen gas sensor. It is indicated that the sensor outputs were increased with the increase of hydrogen gas collection times at the same hydrogen gas concentrations.

Recurrence plot entropy for machine defect severity assessment

  • Yan, Ruqiang;Qian, Yuning;Huang, Zhoudi;Gao, Robert X.
    • Smart Structures and Systems
    • /
    • v.11 no.3
    • /
    • pp.299-314
    • /
    • 2013
  • This paper presents a nonlinear time series analysis technique for evaluating machine defect severity, based on the Recurrence Plot (RP) entropy. The RP entropy is calculated from the probability distribution of the diagonal line length in the recurrence plot, which graphically depicts a system's dynamics and provides a global picture of the autocorrelation in a time series over all available time-scales. Results of experimental studies conducted on a spindle-bearing test bed have demonstrated that, as the working condition of the bearing deteriorates due to the initiation and/or progression of structural damages, the frequency information contained in the vibration signal becomes increasingly complex, leading to the increase of the RP entropy. As a result, RP entropy can serve as an effective indicator for defect severity assessment of rolling bearings.

Development of Deterioration Detecting Sensor in Oil for Diagnosis of Oil-Filled Transformers (유입 변압기 진단을 위한 유중 열화 측정 센서의 개발)

  • Min, Kyeoung-Rae;Yoon, Yong-Han;Kim, Young-Chun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.128-130
    • /
    • 2000
  • This paper develops the deterioration detecting sensor in oil to monitor and diagnose oil-filled transformer more effectively. The on-line inspection of the oil-filled transformers used the temperature, the changes of the capacitance, the $tan{\delta}$ in oil. This sensor was designed based on the concentric cylindrical type so that it could be placed inside of the oil-filled transformer. And comparing to the existing system, it was proven to be appropriate. Establishment of the proposed sensor helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF