• Title/Summary/Keyword: on-device

Search Result 19,670, Processing Time 0.048 seconds

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

A Scenery Word of Pine Tree Extracted in Choi Myoung Hee's Novel 『Honbul』 (최명희의 소설 『혼불』에서 추출한 소나무의 경관언어)

  • Rho, Jae-Hyun;Kim, Hwa-Ok;Park, Yool-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.61-72
    • /
    • 2014
  • Throughout analyzing and construing the words, contexts, and expressive languages used for depicting the pine tree in the novel "Honbul" written by Choi, Myung-Hee the symbolism of the pine and folksy languages used for scenery can be condensed as written below: First, it is explicit that the scenery-words for illustrating the pine tree in "Honbul" are emerged through diverse means methods and expressions. Namely, the reference forms of the pine tree and the expressive means of utilizing words portrays the use of the pine are various and subdivided. Second, the scenery-words found in vocabularies and the contexts of "Honbul" imply various symbolic representation. They not only perform to describe inherent image and symbolism of the pine, but they work for reifying the image of "Honbul" in the narrative structure in "Honbul" as being intrinsic scenery-word. Third, the scenery-words used for expressing aesthetics emerge as synesthetic expressions through the linear beauty and the texture of the pine as well as through five-senses. Forth, on the basis of the inherent symbolism and the image of the pine, the landscape of the background described in "Honbul" deems as a symbolic backdrop. As with then narrative structure of the novel, the pine tree performs as a mediation of the heaven and the earth, god and man, as well as the sacred and the secular. Fifth, scenery-words used for depicting the pine tree are a symbol that represents the spirit and emotion of the character in the novel. Moreover, it is a tool for pursuing the personification of the nature, the deification of the object, and the cosmos of the space. It is also utilized as a device that definitize the ideational image applied to express the landscape of the background of the novel. As mentioned above, the expressions, vocabularies and textures about pine tree represented from "Honbul" are expected to be the beginning of understanding the landscape-images and landscape-languages of pine in not only the setting for this novels, Namwon but also the entire districts of Korea.

Noise-robust electrocardiogram R-peak detection with adaptive filter and variable threshold (적응형 필터와 가변 임계값을 적용하여 잡음에 강인한 심전도 R-피크 검출)

  • Rahman, MD Saifur;Choi, Chul-Hyung;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.126-134
    • /
    • 2017
  • There have been numerous studies on extracting the R-peak from electrocardiogram (ECG) signals. However, most of the detection methods are complicated to implement in a real-time portable electrocardiograph device and have the disadvantage of requiring a large amount of calculations. R-peak detection requires pre-processing and post-processing related to baseline drift and the removal of noise from the commercial power supply for ECG data. An adaptive filter technique is widely used for R-peak detection, but the R-peak value cannot be detected when the input is lower than a threshold value. Moreover, there is a problem in detecting the P-peak and T-peak values due to the derivation of an erroneous threshold value as a result of noise. We propose a robust R-peak detection algorithm with low complexity and simple computation to solve these problems. The proposed scheme removes the baseline drift in ECG signals using an adaptive filter to solve the problems involved in threshold extraction. We also propose a technique to extract the appropriate threshold value automatically using the minimum and maximum values of the filtered ECG signal. To detect the R-peak from the ECG signal, we propose a threshold neighborhood search technique. Through experiments, we confirmed the improvement of the R-peak detection accuracy of the proposed method and achieved a detection speed that is suitable for a mobile system by reducing the amount of calculation. The experimental results show that the heart rate detection accuracy and sensitivity were very high (about 100%).

The Correlation between Critical Micelle Concentration/Surface of Contact Lens Care Solutions Tension and Their Cleaning Efficacy (콘택트렌즈 관리용액의 미셀임계농도 및 표면장력과 세척력 간의 상관관계)

  • Byun, Hyun Young;Sung, Hyung Kyung;Moon, Joon Sik;Lee, A Young;Kwon, Se Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • Purpose: The present study was aimed to figure out the correlation amongst the evaluation methods for critical micelle concentration, surface tension and protein cleaning efficacy to evaluate cleaning efficacy of contact lens care products. Methods: The critical micelle concentration of surfactants and the actual concentration of surfactants in contact lens care solutions were investigated by employing references published and related information. Surface tension of contact lens care solutions was measured by surface tension device at $25{\pm}1^{\circ}C$, and contact lenses made of lotrafilcon A, comfilcon A and balafilcon A were washed with contact lens care solutions after the incubation in artificial tears for 14 days and their cleaning efficacy was compared. Results: Among the 22 contact lens care products, 9 products provided the label of the concentration of surfactant, and 7 products showed higher concentration of surfactant than the critical micelle concentration reported in references. As a result of measuring surface tension, the surface tension of lens care products for soft contact lens was generally lower than other care products. When examined the removal effect of protein deposited on lens surface, it was known that the care products having lower surface tension showed higher protein removal efficiency. Conclusions: The surface tension is low when surfactant concentration in contact lens care solutions is high, and the removal effect of protein deposited is accordingly increased with the decrease of surface tension. Thus, these indicate the correlation amongst the evaluation methods for cleaning efficacy.

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Risk Assessment about Heavy Metals Contamination in Agricultural Products at Abandoned Mine Area (폐광산 인근 지역에서 생산되는 농산물의 중금속 오염도 평가)

  • An, Jae-Min;Chang, Soon-Young;Hwang, Hyang-Ran;Park, Dae-Han;Lee, Bom-Nae;Kim, Saet-Byeol;Lee, Gwang-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.1
    • /
    • pp.10-19
    • /
    • 2020
  • BACKGROUND: This study was to carry out risk assessment of contamination of cadmium (Cd), lead (Pb), and inorganic arsenic (I-As) in agricultural products of 25 crops from the abandoned mine areas. The 36 typical investigation sites located in Gyeongbuk provincial area were selected by considering the heavy metal levels, that had been known that the amount of the heavy metals exceeded the contamination level based on the previous survey. METHODS AND RESULTS: Cadmium, lead, and total arsenic (T-As) concentrations were determined using microwave device and ICP-MS. Inorganic arsenic was determined by HPLC-ICP-MS. The limits of quantification for heavy metals were 0.59 ㎍/kg for Cd, 0.42 ㎍/kg for Pb, 0.55 ㎍/kg for T-As, and sum of As (III) (1.74 ㎍/kg) and As (V) (2.25 ㎍/kg) for I-As, respectively. The contents of Cd, Pb, and I-As (only rice) were N.D.-0.958 mg/kg, N.D.-0.227 mg/kg, and 0.082 mg/kg, respectively, in the agricultural products. For risk assessment, dietary exposures of heavy metals through usual intake were 5.20×10-4-7.15×100 ㎍/day for Cd, 7.00×10-5-7.75×10-1 ㎍/day for Pb, and 1.17×101 ㎍/day for I-As, taking 0.01-14.37%, 0.01-2.05%, and 15.16% as risk indices, respectively. CONCLUSION: It requires to consider the critical levels of heavy metals in agricultural products due to unexpectedly high levels in a few places, while concentrations of heavy metals in the samples were relatively low in most areas.

Analysis of the growth environment and fruiting body quality of Pleurotus eryngii cultivated by Smart Farming (큰느타리(새송이)버섯 스마트팜 재배를 통한 생육환경 분석 및 자실체 품질 특성)

  • Kim, Kil-Ja;Kim, Da-Mi;An, Ho-Sub;Choi, Jin-Kyung;Kim, Seon-Gon
    • Journal of Mushroom
    • /
    • v.17 no.4
    • /
    • pp.211-217
    • /
    • 2019
  • Currently, cultivation of mushrooms using the Information and Communication Technology (ICT)-based smart farming technique is increasing rapidly. The main environmental factors for growth of mushrooms are temperature, humidity, carbon dioxide (CO2), and light. Among all the mentioned factors, currently, only temperature has been maintained under automatic control. However, humidity and ventilation are controlled using a timer, based on technical experience.Therefore, in this study, a Pleurotus eryngii first-generation smart farm model was set up that can automatically control temperature, humidity, and ventilation. After installing the environmental control system and the monitoring device, the environmental condition of the mushroom cultivation room and the growth of the fruiting bodies were studied. The data thus obtained was compared to that obtained using the conventional cultivation method.In farm A, the temperature during the primordia formation stage was about 17℃, and was maintained at approximately 16℃ during the fruiting stage. The humidity was initially maintained at 95%, and the farm was not humidified after the primordia formation stage. There was no sensor for CO2 management, and the system was ventilated as required by observing the shape of the pileus and the stipe. It was observed that, the concentration of CO2 was between 700 and 2,500 ppm during the growth period. The average weight of the mushrooms produced in farm A was 125 g, and the quality was between that of the premium and the first grade.In farm B. The CO2 sensor was in use for measurement purposes only; the system was ventilated as required by observing the shape of the pileus and the stipe. During the growth period, the CO2 concentration was observed to be between 640 and 4,500 ppm. The average weight of the mushrooms produced in farm B was 102 g.These results indicate that the quality of the king oyster mushroom is determined by the environmental conditions, especially by the concentration of CO2. Thus, the data obtained in this study can be used as an optimal smart farm model, where, by improving the environmental control method of farm A, better quality mushrooms were obtained.

Risk Assessment Aluminum Levels of Circulating Agricultural Products in Korea (국내 다소비 농산물의 알루미늄 농도 모니터링 및 농산물 섭취로 인한 위해도 평가)

  • An, Jae-Min;Hong, Kyong-Suk;Kim, Sung-Youn;Kim, Ji-Hye;Yu, Kyong-Eun;Kim, Hyo-Young;Park, Hyoung-Dal;Lee, Jae-Hwon;Kim, Dong-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.336-344
    • /
    • 2015
  • BACKGROUND: This study was carried out to collect occurrence data on aluminum in 12 type agricultural products and assess dietary exposure risk to the Korean population health for aluminum concentration in agricultural products.METHODS AND RESULTS: Aluminum analysis samples were performed using microwave device and Inductively Coupled Plasma Optical Emission Spectrometer. The LOD(Limit of Detection) for aluminum was 0.851 μg/kg, while the LOQ(Limit of Quantitation) was 2.838 μg/kg and recovery was 97.6% for aluminum. The average levels of aluminum in mg/kg were 0.526 for rice, 0.546 for Korean cabbage, 1.316 for corn, 6.207 for soybean, 0.549 for sweet potato, 0.257 for potato, 6.963 for spinach, 1.213 for carrot, 0.524 for garlic, 0.950 for radish, 1.015 for leek, and 3.511 for Welsh onion. The dietary exposures of aluminum through usual intake were polished rice 89.31 μg/day, Korean cabbage 33.14 μg/day, corn 0.66 μg/day, soybean 3.72 μg/day, sweet potato 6.86 μg/day, potato 4.96 μg/day, spinach 45.96 μg/day, carrot 6.79 μg/day, garlic 2.36 μ g/day, radish 7.32 μg/day, leek 2.23 μg/day and Welsh onion 43.89 μg/day, taking 0.57%, 0.21%, 0.00%, 0.02%, 0.04%, 0.03%, 0.04%, 0.04%, 0.02%, 0.05%, 0.01% and 0.28% of PTWI(2 mg/kg b.w./week), respectively.CONCLUSION: The levels of overall dietary exposure to aluminum for Korean population through intake of agricultural product was far below the recommended JECFA level, indicating of least possibility of risk.