• Title/Summary/Keyword: on resistance

Search Result 21,654, Processing Time 0.051 seconds

A Study on the Improvement of Electrode Installation for Measurement of Ground Resistance through Investigation on the Spot in Buildings (현장조사를 통한 건축물 접지저항 측정용 전극 설치의 개선에 관한 연구)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kil, Gyung-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.92-97
    • /
    • 2011
  • This paper deals with the improvement of electrode installation for measurement of ground resistance through investigation on the spot in buildings. The investigation was carried out for an earthing terminal board for measurement of ground resistance, installation of auxiliary electrode, etc. The criteria value is set up by measuring method of ground resistance in international standard. In case of inadequate installation of auxiliary electrode, a relative error is analyzed and adequate installation method of auxiliary electrode is proposed. As a consequence, it is necessary to write direction of ground and equipment, and separate auxiliary electrode for measurement of ground resistance in order to minimize measuring error.

A Study on the Factors of Intention of Continued Use of the Convenient Payment Service: The Perspectives of the Flow, the Reliability and the Innovative Resistance (간편결제 서비스의 지속사용의도에 영향을 미치는 요인에 관한 연구: 플로우, 신뢰 및 혁신저항을 중심으로)

  • Son, Dal Ho
    • The Journal of Information Systems
    • /
    • v.30 no.1
    • /
    • pp.1-20
    • /
    • 2021
  • Purpose The purpose of this study is to deduct the motivative factors such as perceived value, trust, innovative resistance and flow from the pervious studies and to examine the effect of the motivative factors in the continued use of convenient payment service. Design/methodology/approach This study made a design of the research model by integrating the factors deducted from the Value-based Adoption Model and the Innovative Resistance Model with the factors deducted from the Flow Theory. Findings Results showed that perceived value had a significant effect on trust and innovative resistance. Moreover, trust had a significant effect on flow and continued use. Finally, innovative resistance and flow had a significant effect on continued use. However, the research model in this study was derived from a behavioral point of view, therefore, this model needs to combine the various factors of related fields.

Investigation of Floor Surface Finishes for Optimal Slip Resistance Performance

  • Kim, In-Ju
    • Safety and Health at Work
    • /
    • v.9 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • Background: Increasing the slip resistance of floor surfaces would be desirable, but there is a lack of evidence on whether traction properties are linearly correlated with the topographic features of the floor surfaces or what scales of surface roughness are required to effectively control the slipperiness of floors. Objective: This study expands on earlier findings on the effects of floor surface finishes against slip resistance performance and determines the operative ranges of floor surface roughness for optimal slip resistance controls under different risk levels of walking environments. Methods: Dynamic friction tests were conducted among three shoes and nine floor specimens under wet and oily environments and compared with a soapy environment. Results: The test results showed the significant effects of floor surface roughness on slip resistance performance against all the lubricated environments. Compared with the floor-type effect, the shoe-type effect on slip resistance performance was insignificant against the highly polluted environments. The study outcomes also indicated that the oily environment required rougher surface finishes than the wet and soapy ones in their lower boundary ranges of floor surface roughness. Conclusion: The results of this study with previous findings confirm that floor surface finishes require different levels of surface coarseness for different types of environmental conditions to effectively manage slippery walking environments. Collected data on operative ranges of floor surface roughness seem to be a valuable tool to develop practical design information and standards for floor surface finishes to efficiently prevent pedestrian fall incidents.

Microstructural Characteristics of Zircaloy-4 Nuclear Fuel Cladding Welds by Resistance Upset Welding Processes (저항 업셋 용접방식에 따른 Zircaloy-4 핵연료 피복재 용접부의 미세조직 특성)

  • 고진현;김상호;박춘호;김수성
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.98-104
    • /
    • 2002
  • A study on microstructures of welds for Zircaloy-4 sheath end closure by the resistance upset welding methods was carried out. Two upset welding process variations such as magnetic farce and multi-impulse resistance welding were used. Grain size and microhardness across welds were analysed in terms of welding parameters. Magnetic farce resistance weld with one cycle of unbalanced mode has smaller upset length and $\alpha-grain$ size in heat affected zone than those of multi-impulse resistance weld because of lower heat input and shorter welding time. Heat affected zone formed by two upset resistance welding variations revealed fine Widmanstatten structure or martensitic ${\alpha}'$ structure due to the high heating rate and foster cooling rate. Magnetic force resistance welds showed recrystallized grains before grain growth, whereas multi-impulse resistance welds showed full grain growth.

A Study on Effect of Technological Innovation Activities on Innovation Performance in Firms: Focused on the Moderating Effect of Innovation Resistance and Performance (기업의 기술혁신 활동이 혁신성과에 미치는 영향연구: 혁신저항의 매개적 효과를 중심으로)

  • Park, Jugyeong;Lee, Seolbin
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.12 no.5
    • /
    • pp.89-99
    • /
    • 2017
  • Although the technological innovation activities have depended on corporate, organizational and personal capabilities and activities, innovation resistance to practice was not actively considered in previous studies. This study is intended to the effects of corporate technology innovation capabilities and activities on intra-organizational innovation resistance and performance by compensating the limit of previous studies. To achieve this, a survey was empirically carried out to 293 domestic IT and BT companies. First, technological innovation competencies had a positive effect on technological innovation resistance, adopting hypothesis 1. Second, technological innovation activities had no positive effect on technological innovation resistance, rejecting hypothesis 2. Third, technological innovation resistance had a positive effect on technological innovation performance, adopting hypothesis 3. Fourth, technological innovation resistance was positively mediated in the relationship between technological innovation competencies and technological innovation performance, adopting hypothesis 4. Fifth, technological innovation resistance was not positively mediated in the relationship between technological innovation activities and technological innovation performance, rejecting hypothesis 5. Overall, the higher technological innovation competencies had a significant effect on technological innovation resistance. Consequently, technological innovation resistance can improve or reduce technological innovation competencies and performance depending on the level of resistance.

  • PDF

ANALYTICAL SIMULATION OF TRAVEL RESISTANCE OF THE RUBBER CRAWLER SYSTEM FOR FARM MACHINERY

  • Inaba, S.;Inoue, E.;Hashiguchi, K.;Matsuo, T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.139-145
    • /
    • 2000
  • The mechanism of the inner resistance in a rubber crawler system has been investigated to reduce the power requirement (Kitano et al. 1994). The rolling resistance of the track roller, which is one of the major inner resistances, was measured for seven different vertical loads. The rolling resistance changed periodically and could be classified into three types. In case of the vertical load less than 500N, the rolling resistance was almost constant. For the vertical load greater than 500N, the maximum value of the rolling resistance increased. Further more in case of the vertical load greater than 1200N, negative resistance appeared. Analytical simulation of the travel resistance based on experimental results and static equilibrium equations derived from three-dimension mechanical model for the rubber crawler system. It was found that the simulation method was carried out to evaluate the travel resistance occurred by the rolling resistance of the track roller. The rolling resistance for each track roller arrangement and effects of the lug phase in the right and left rubber crawler could be estimated quantitatively.

  • PDF

Cooperative Interaction between Acid and Copper Resistance in Escherichia coli

  • Kim, Yeeun;Lee, Seohyeon;Park, Kyungah;Yoon, Hyunjin
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.5
    • /
    • pp.602-611
    • /
    • 2022
  • The persistence of pathogenic Escherichia coli under acidic conditions poses a serious risk to food safety, especially in acidic foods such as kimchi. To identify the bacterial factors required for acid resistance, transcriptomic analysis was conducted on an acid-resistant enterotoxigenic E. coli strain and the genes with significant changes in their expression under acidic pH were selected as putative resistance factors against acid stress. These genes included those associated with a glutamate-dependent acid resistance (GDAR) system and copper resistance. E. coli strains lacking GadA, GadB, or YbaST, the components of the GDAR system, exhibited significantly attenuated growth and survival under acidic stress conditions. Accordantly, the inhibition of the GDAR system by 3-mercaptopropionic acid and aminooxyacetic acid abolished bacterial adaptation and survival under acidic conditions, indicating the indispensable role of a GDAR system in acid resistance. Intriguingly, the lack of cueR encoding a transcriptional regulator for copper resistance genes markedly impaired bacterial resistance to acid stress as well as copper. Conversely, the absence of YbaST severely compromised bacterial resistance against copper, suggesting an interplay between acid and copper resistance. These results suggest that a GDAR system can be a promising target for developing control measures to prevent E. coli resistance to acid and copper treatments.

Analytical Study for Improving the Fire Resistance of Composite Beam depend on Section Change (합성보의 단면변경을 통한 내화성능 향상에 관한 해석 연구)

  • Park, Soo-Young;Kim, Hyung-Jun;Hong, Kap-Pyo
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.80-87
    • /
    • 2011
  • On the result of load-bearing fire test to confirm the fire resistance of a composit beam, if the composit beam has lower fire resistance than required standard, it can be improved by section change. But if there are many types of section change, it takes much time and cost owing to conducting many tests. On this study, it was confirmed which part of the asymmetric H-section composit beam affected most on fire resistance by heat-transfer analysis. Then, we checked the tendency of improving fire resistance depend on section change by heat-transfer and non-linear structural analysis and suggested a changed section having 1-hour fire resistance.

Designing method for fire safety of steel box bridge girders

  • Li, Xuyang;Zhang, Gang;Kodur, Venkatesh;He, Shuanhai;Huang, Qiao
    • Steel and Composite Structures
    • /
    • v.38 no.6
    • /
    • pp.657-670
    • /
    • 2021
  • This paper presents a designing method for enhancing fire resistance of steel box bridge girders (closed steel box bridge girder supporting a thin concrete slab) through taking into account such parameters namely; fire severity, type of longitudinal stiffeners (I, L, and T shaped), and number of longitudinal stiffeners. A validated 3-D finite element model, developed through the computer program ANSYS, is utilized to go over the fire response of a typical steel box bridge girder using the transient thermo-structural analysis method. Results from the numerical analysis show that fire severity and type of longitudinal stiffeners welded on bottom flange have significant influence on fire resistance of steel box bridge girders. T shaped longitudinal stiffeners applied on bottom flange can highly prevent collapse of steel box bridge girders towards the end of fire exposure. Increase of longitudinal stiffeners on bottom flange and web can slightly enhance fire resistance of steel box bridge girders. Rate of deflection-based criterion can be reliable to evaluate fire resistance of steel box bridge girders in most fire exposure cases. Thus, T shaped longitudinal stiffeners on bottom flange incorporated into bridge fire-resistance design can significantly enhance fire resistance of steel box bridge girders.

Comparison of the Fire Resistance Performance of Firestop Systems on Non-Metallic Pipes, Based on the Type of Through-Penetration Sleeve Used (비금속관 설비관통부의 슬리브 종류에 따른 내화성능 비교)

  • Jeong, A-Yeong;Choi, Hong-Beom;Park, Jin-O;Lee, Hyung-Do
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.301-302
    • /
    • 2023
  • In this study, we aimed to identify changes in fire resistance according to the type of sleeves used for pipe penetrations and to examine their accreditation of fire resistance performance and use them as basic data. The test results of fire resistance according to the type of sleeve used in non-metallic pipe facilities showed that the temperature on the support side was higher for sleeves with higher thermal conductivity. For the temperature on the surface of the pipes, in the case of galvanized steel plates, steel pipes, and structures without sleeves, the highest temperature was observed after the expansion of the firestop material for 46 to 53 minutes and then decreased. PVC sleeves showed a steady increase in temperature until 53 minutes, after which the temperature did not increase further. In addition, for non-metallic pipes, the effect of the type of sleeve on fire resistance is considered to be insignificant because the lower part (heating direction of the furnace) under the support structure is cut off to block the heat during the two-hour fire resistance test.

  • PDF