• Title/Summary/Keyword: omega-3

Search Result 2,914, Processing Time 0.035 seconds

A Study on Properties of N-type ZnS Deposited at Various RF Power for Solar Cell Applications (RF Power에 따른 태양전지용 N-type ZnS 특성연구)

  • Yang, Hyeon-Hun;Kim, Han-Wool;Jeong, Woon-Jo;Lee, Suk-Ho;So, Soon-Youl;Park, Gye-Choon;Lee, Jin;Chung, Hea-Duck
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.574-577
    • /
    • 2011
  • In this study, we use the $2.5cm{\times}7.5cm$ soda lime glass as the substrate. We used the ultrasonicator. Glass was dipped in the acetone, methanol and DI water respectively for 10 minutes. Ar(99.99%)gas was used as the sputtering gas. We varied the RF power between 100~175 W with 25 W steps. Base pressure was kept by turbo molecular pump at $3.0{\times}10^{-6}$ torr. Working pressure was kept by injection of Ar gas. ZnS thin films were deposited with the radio frequency magnetron sputtering technique at various temperatures and sputtering powers. It is also clearly observed that, the intensity of the (111) XRD peak increases with increasing the RF power. Electrical properties were measured by hall effect methods at room temperature. The resistivity, carrier concentration, and hall mobility of ZnS deposited on glass substrate as a function of sputtering power. It can be seen that as the sputtering power increase from 100 to 175 W, the resistivity of the films on glass decreased significantly from $8.1{\times}10^{-2}$ to $1.2{\times}10^{-3}\;{\Omega}{\cdot}cm$. This behavior could be explained by the effect of the sputtering power on the mobility and carrier concentration. When the RF power increases, the carrier concentration increases slightly while the resistivity decreases significantly. These variation originate from improved crystallinity and enhanced substitutional doping as the sputtering power increases.

Relaxation Effects of Rubus coreanus in Isolated Rabbit Corpus Cavernosum Smooth Muscle (복분자(覆盆子)의 토끼 음경해면체 평활근 이완효과)

  • Park, Sun Young;Lee, Pyeng Jae;Shin, Seon Mi;Kim, Ho Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.400-408
    • /
    • 2013
  • This study aimed to investigate the relaxation effects and its underlying mechanisms of Rubus coreanus(RC) extract in contracted rabbit corpus cavernous tissues by phenylephrine(PE) $1{\mu}M$. In order to define the relaxation effects of RC, rabbit corpus cavernous tissues were prepared in $2{\times}2{\times}6mm$ sized strip. The dose-dependent relaxation responses of RC at 0.01-3.0 $mg/m{\ell}$ in contracted strips induced by PE were measured and also observed after endothelial denudation. To analyze the underlying mechanisms of RC-induced relaxation, indomethacin(IM), tetraethylammonium chloride(TEA), $N{\omega}$-nitro-L-arginine (L-NNA), methylene blue(MB) were treated before RC extract infused into precontracted strips induced by PE. To study the effect of RC extract on influx of extracellular $Ca^{2+}$ in corpus cavernous strips, calcium chloride(Ca) 1 mM infused into precontracted strips induced by PE after pretreatment of RC extract in $Ca^{2+}$-free krebs-ringer solution. To investigate cytotoxic activity and nitric oxide(NO) concentration of RC extract on human umbilical vein endothelial cell(HUVEC), cell viability on HUVEC was measured by MTT assay, and NO concentration was measured by Griess reagent system. The cavernous strips were significantly relaxed by RC extract at 1.0 $mg/m{\ell}$, 3.0 $mg/m{\ell}$ and the relaxation responses to RC were inhibited significantly by endothelial disruption. The pretreatment of IM, TEA didn't affect RC extract-induced endothelium-dependent relaxation, but the pretreatment of L-NNA, MB reduced RC extract-induced endothelium-dependent relaxation. When $Ca^{2+}$ was supplied the cavernous strips which were precontracted by PE in a $Ca^{2+}$-free krebs-ringer solution, contraction of strips was increased, but pretreatment of RC inhibited contractile response to $Ca^{2+}$. When RC extract was applicated on HUVEC, NO concentration was increased. Our findings show that RC extract exerts a relaxing effect on corpus cavernosum in part by suppressing influx of extracellular $Ca^{2+}$ through activating the NO-cGMP system.

Relevance of Population Group Properties and Fluctuation of DHA Content of The Pacific Oyster, Crassostrea gigas in Bukman, Korea (북만 양식굴의 개체군 특성과 DHA 함량조성의 변동)

  • KIM Yong-Sool;KANG Seok-Joong;JEONG Woo-Geon;CHO Chang-Hwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.2
    • /
    • pp.210-216
    • /
    • 1998
  • Relationship between population group properties and docosahexaenoic acid (DHA) content of the Pacific oyster had been carried out at the Bukman oyster farm near Tongyeong based on the regular monthly sampling from November 1994 through April 1996. DHA content in lipids was least abundant in June and most abundant in November. Minimum DHA content close to 'zero' in lune suggests that much of DHA are being used for maturing and discharging of eggs and sperms, in consideration of the fact that lure is the spawning periods of the oyster. The corelationships among DHA content, mortality, and growth coefficient, have not been recognized. The approximate positive relations have been acknowledged between DHA content and the individual density in times of harvest, and also the individual weight. But it seems that the relaltions between DHA content and the individual weight are not directly related, rather it seems that it is the result from the population density effects caused by the relations between DHA and the number of individuls. But the meaning of the above mentioned relations can not be clearly defined yet.

  • PDF

Isolation and Characterization of a Novel Agar-Degrading Marine Bacterium, Gayadomonas joobiniege gen, nov, sp. nov., from the Southern Sea, Korea

  • Chi, Won-Jae;Park, Jae-Seon;Kwak, Min-Jung;Kim, Jihyun F.;Chang, Yong-Keun;Hong, Soon-Kwang
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.11
    • /
    • pp.1509-1518
    • /
    • 2013
  • An agar-degrading bacterium, designated as strain $G7^T$, was isolated from a coastal seawater sample from Gaya Island (Gayado in Korean), Republic of Korea. The isolated strain $G7^T$ is gram-negative, rod shaped, aerobic, non-motile, and non-pigmented. A similarity search based on its 16S rRNA gene sequence revealed that it shares 95.5%, 90.6%, and 90.0% similarity with the 16S rRNA gene sequences of Catenovulum agarivorans $YM01^T$, Algicola sagamiensis, and Bowmanella pacifica W3-$3A^T$, respectively. Phylogenetic analyses demonstrated that strain $G7^T$ formed a distinct monophyletic clade closely related to species of the family Alteromonadaceae in the Alteromonas-like Gammaproteobacteria. The G+C content of strain $G7^T$ was 41.12 mol%. The DNA-DNA hybridization value between strain $G7^T$ and the phylogenetically closest strain $YM01^T$ was 19.63%. The genomes of $G7^T$ and $YM01^T$ had an average ANIb value of 70.00%. The predominant isoprenoid quinone of this particular strain was ubiquinone-8, whereas that of C. agarivorans $YM01^T$ was menaquinone-7. The major fatty acids of strain $G7^T$ were Iso-$C_{15:0}$ (41.47%), Anteiso-$C_{15:0}$ (22.99%), and $C_{16:1}{\omega}7c/iso-C_{15:0}2-OH$ (8.85%), which were quite different from those of $YM01^T$. Comparison of the phenotypic characteristics related to carbon utilization, enzyme production, and susceptibility to antibiotics also demonstrated that strain $G7^T$ is distinct from C. agarivorans $YM01^T$. Based on its phenotypic, chemotaxonomic, and phylogenetic distinctiveness, strain $G7^T$ was considered a novel genus and species in the Gammaproteobacteria, for which the name Gayadomonas joobiniege gen. nov. sp. nov. (ATCC BAA-2321 = $DSM25250^T=KCTC23721^T$) is proposed.

The Effects of Wearing Roller Shoes on Muscle Activity in The Lower Extremity During Walking (롤러신발과 일반신발의 착용 후 보행 시 하지근의 근전도 비교)

  • Chae, Woen-Sik;Lim, Young-Tae;Lee, Min-Hyung;Kim, Jung-Ja;Kim, Youn-Joung;Jang, Jae-Ik;Park, Woen-Kyoon;Jin, Jae-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to compare muscle activity in the lower extremity during walking wearing jogging and roller shoes. Twelve male middle school students (age: 15.0 yrs, height 173.7 cm, weight 587.7 N) who have no known musculoskeletal disorders were recruited as the subjects. Seven pairs of surface electrodes (QEMG8, Laxtha Korea, gain = 1,000, input impedance >$1012{\Omega}$, CMMR >100 dB) were attached to the right-hand side of the body to monitor the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), tibialis anterior (TA), and medial (GM) and lateral gastrocnemius (GL) while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and EMG recordings. EMG data were filtered using a 10 Hz to 350 Hz Butterworth band-passdigital filter and further normalized to the respective maximum voluntary isometric contraction EMG levels. For each trial being analyzed, five critical instants and four phases were identified from the recording. Averaged IEMG and peak IEMG were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). The VM, TA, BF, and GM activities during the initial double limb stance and the initial single limb stance reduced significantly when going from jogging shoe to roller shoe condition. The decrease in EMG levels in those muscles indicated that the subjects locked the ankle and knee joints in an awkward fashion to compensate for the imbalance. Muscle activity in the GM for the roller shoe condition was significantly greater than the corresponding value for the jogging shoe condition during the terminal double limb stance and the terminal single limb stance. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the GM activity for the roller shoe condition increased. It seems that there are differences in muscle activity between roller shoe and jogging shoe conditions. The differences in EMG pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine joint kinematics during walking with roller shoes.

70nm NMOSFET Fabrication with Ultra-shallow $n^{+}-{p}$ Junctions Using Low Energy $As_{2}^{+}$ Implantations (낮은 에너지의 $As_{2}^{+}$ 이온 주입을 이용한 얕은 $n^{+}-{p}$ 접합을 가진 70nm NMOSFET의 제작)

  • Choe, Byeong-Yong;Seong, Seok-Gang;Lee, Jong-Deok;Park, Byeong-Guk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2001
  • Nano-scale gate length MOSFET devices require extremely shallow source/drain eftension region with junction depth of 20∼30nm. In this work, 20nm $n^{+}$-p junctions that are realized by using this $As_{2}^{+}$ low energy ($\leq$10keV) implantation show the lower sheet resistance of the $1.0k\Omega$/$\square$ after rapid thermal annealing process. The $As_{2}^{+}$ implantation and RTA process make it possible to fabricate the nano-scale NMOSFET of gate length of 70nm. $As_{2}^{+}$ 5 keV NMOSFET shows a small threshold voltage roll-off of 60mV and a DIBL effect of 87.2mV at 100nm gate length devices. The electrical characteristics of the fabricated devices with the heavily doped and abrupt $n^{+}$-p junctions ($N_{D}$$10^{20}$$cm^{-3}$, $X_{j}$$\leq$20nm) suggest the feasibility of the nano-scale NMOSFET device fabrication using the $As_{2}^{+}$ low energy ion implantation.

  • PDF

Forest Structure in Relation to Altitude and Part of Slope in a Valley Forest at Sanggyesa Chirisan national Prark (지리산국립공원 쌍계사지역 계곡부의 해발고와 사면부위에 따른 산림구조)

  • 서영권
    • Korean Journal of Environment and Ecology
    • /
    • v.13 no.4
    • /
    • pp.340-347
    • /
    • 2000
  • 지리산국립공원의 쌍계사지의 불일폭포-성불재 계곡부(해발 600-1.1200m)의 해발고와 사면부위에 따른 교목층의 산림구조를 조사하기 위하여 해발고와 사면부위에 따라 42개 조사구를 설정하였다 교목상층의 밀도 평균흉고직경 흉고단면적의 범위는 각각 545-1,700본/ha 11.0-23.5cm, 19.1-27.8m2/ha 이었다 교목상층의 평균흉고직경과 흉고단면적 교목층 전체의 흉고단면적은 계곡중부에서 가장컸다 해발고가 높아짐에 따라 중요치가 증가하는 경향을 보이는 수종은 신갈나무 소나무 등이었으며 감소하는 수종은 굴참나무 졸참나무, 비목나무 등이었다 사면하부에서 상부로 갈수록 중요치가 증가하는 수종은 굴참나무 쇠물푸레 철쭉꽃 등이었으며 감소하는 수종은 노각나무 비목나무 느티나무 당단풍 때죽나무 등이었다 해발고와 사면부위가 높을수록 종수와 종다양도는 감소하였으며 해발고대별 종다양도는 0.626-1.320 의범위를 보였다 계곡정부를 제외한 해발고대간 유사도지수는 36.1-60.6% 사면부위간 유사도지수는 59.2-74.4% 로서 사면부위보다 해발고에 따른 종구성 상태의 차이가 심한 것으로 나타났다 수종별 중요치에 의한 Cluster 분석결과 계곡하부의에 위치한 서어나무-활엽수군집 계곡상부의 사면중 하부에 위치한 신갈나무-활엽수군집 계곡정부와 계곡상부의 사면상부에 위치한 신갈나무-소나무군집 등 4개 유형군집으로 구분되었다 종상관 분석결과 소나무 신갈나무 쇠물푸레 철쭉꽃 등 4개 수종간 비목나무 산뽕나무 생강나무 등 3개 수종간에는 유의적인 정의 상관이 있었다. 신갈나무, 쇠물푸레 철쭉꽃 등은 졸참나무와 소나무 쇠물푸레 등은 비목나무 서어나무와 유의적인 부의 상관이 있었다.증가에 따라 250 g/L까 지 증가하여 최대 51.0%의 수율과 0.63 g/L-h의 생산성을 나타내었다. 얻을 수 있었다. 따라서 이 방법이 일단 생산성 향상을 위한 세포의 고농도 배양에는 조사한 여러 배양 시스템 중에 가장 효율적인 시스템임올 알 수 있었다 하지만 이 시스템 에서 포도당을 낮은 level로 유지할 수 있었으나, 초산의 과도한 축적으로 항체 생산성의 향상은 예상에 비해 크지 않았다. 81%), C18 0(12.38%), C18: 1(25.93%), C22:6(9.95%)이며 결합지방질(結合脂肪質)은 C14 : 0(11.60%), C16 : 0(18.94%), C16: 1(10.42%). C18 : 1(10.89%), C22 : 6(23.44%)이었다. 총필수지방산(總必須脂肪酸) 함량(含量)은 극성지방질(極成脂肪質)$(20.14{\sim}31.12%)$이 비극성지방질(非極成脂肪質)$(6.97{\sim}11.13%)$보다 훨씬 높았고, 결합지방질(結合脂肪質)이 유리지방질(遊離脂肪質)보다 높았으며 부위별(部位別)로는 피부(皮部)$(15.18{\sim}15.41%)$가 육질부(肉質部)$(6.97{\sim}11.13%)$보다 높았다. 또${\omega}3$고도부포화지방산(高度不飽和脂肪酸) 함량(含量)은 육질부(肉質部)$(15.15{\sim}28.32%)$가 피부(皮部)$(6.77{\sim}18.18%)$나 내장부(內臟部)$(8.35{\sim}9.74%)$보다 높았으며, 육질부(肉質部)에서는 극성지방질(極成脂肪質)

  • PDF

An Effective Mitigation Method on the EMI Effects by Splitting of a Return Current Plane (귀환 전류 평면의 분할에 기인하는 복사 방출 영향의 효과적인 대책 방법)

  • Jung, Ki-Bum;Jun, Chang-Han;Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.376-383
    • /
    • 2008
  • Generally a return current plane(RCP) of high speed digital and analog part is partitioned. This is achieved in order to decrease the noise interference between subsystem in PCBs(Printed Circuit Boards). However, when the connected signal line exists between each subsystem, this partition will cause unwanted effects. In a EMI(Electromagnetic Interference) point of view, the partition of the return current plane becomes a primary factor to increase the radiated emission. Component bridge(CB) is used for the way of maintaining radiated emission, still specific user's guide doesn't give sufficient principle. In a view point of EMI, design principle of multi-CB using method will be analyzed by measurement. And design principle of noise mitigation will be provided. Generally interval of multi-CB is ${\lambda}/20$ ferrite bead. In this study, When multi-CB connection is applied, design principle of ferrite bead and chip resistor is proved by measurement. Multi-connected chip resistance$(0{\Omega})$ is proved to be more effective design method in the point of EMI.

레이저 유도 형광법(Laser Induced Fluorescence)을 이용한 플라즈마 방전 표시기(Plasma Display Panel)내의 전계 측정에 관한 연구

  • 김정훈;이준학;최영욱;양진호;황기웅
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.232-232
    • /
    • 1999
  • 교류형 플라즈마 방전 표시기(AC Plasma Display Panel, AC PDP)에 사용되는 플라즈마는 그 부피가 너무 작아서 플라즈마에 변화를 일으키지 않고 그 물성을 관측하기란 쉬운일이 아니다. 그래서 주로 PDP 내의 물성을 관측하는 데 시뮬레이션에 의존하게 된다. 그 물성중에 PDP내의 전계 분포에 대한 정보는 방전의 형성 및 소멸에 대한 많은 단서를 제공하고 있다. 특히 AC PDP의 경우, 유전체에 형성되는 벽적하(wall charge)가 방전의 형성 및 PDP 구동에 중요한 역할을 하는데, 이는 PDP 내의 전계 분포를 살펴봄으로써 대략 예측할 수 있다. 본 연구에서는 시뮬레이션에 의존하지 않고, 직접 레이저 유도 형광법을 이용하여 AC PDP 내의 전계를 측정하였다. 방전 가스인 헬륨(He)의 에너지 준위는 전계의 크기에 따라 에너지 준위가 변화하여, Rydberg(n$\geq$8) 준위가 여러 개의 준위로 나누어지는 현상이 일어나는데, 이를 Stack 효과라고 한다. 따라서 전계의 세기가 커짐에 따라서 각 준위와 준위 사이 값(splitting)이 커지는데, 이를 이용하면 전계를 측정할 수 있다. 즉, 헬륨 원자를 여기시키는 레이저 파장을 변화시키면서 관측되는 레이저 유도 형광 신호를 관측하면, 준위의 splitting을 관측할 수 있다. 본 연구에서는 PDP 내의 전계의 시간적 변화를 관측하였다. 50%, 40kHz의 구형파를 PDP의 두 전극에 가하였을 때, 플라즈마가 켜진 상태뿐만 아니라 플라즈마가 꺼진 후에도 전계에 의한 Splitting 신호가 관측이 되었는데, 전계로 환산하였을 때, 그 값은 대략 수 kV/cm의 값을 갖았는데, 이는 wall charge에 의한 값으로 사료된다.결과로 생각되어진다.플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러

  • PDF

Accuracy of Hybrid Navigation System Combining Dead Reckoning and Loran C (추측항법과 Loran C항법을 결합한 Hybrid 항법의 정도)

  • Lee, Won-Woo;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 1984
  • Recently, Hybrid Navigation Systems combining Omega, NNSS, Loran C and Dead reckoning etc. served to give us highly accurate ship's position, and a number of ships are equipped with these navigation systems. In order to evaluate for the accuracy of this navigation system observations of Loran C, 5970 and 9970 chains and Radar at the same time were made on board m.s Jeonbuk 401 and 403 training ships of Gunsan Fisheries Collage at nine stations in the yellow sea from July, 1982 to June, 1983, and then were done by the Hybrid Navigation System combining Dead reckoning and Loran C at the same areas. The authors investigated the accuracy of the Hybrid Navigation System based on measurements of the relative positional error which is defined as the difference between the position fixed by this system or the Loran C system, and the one by the Radar. The obtained results are as follows; 1. The mean standard deviation of the time difference of Loran C were about 0.21$\mu$s in 9970 chain and about 0.06$\mu$s in 5970 chain, and the fluctuation of the time difference of Loran C in 5970 chain was smaller than that in 9970 chain. 2. The positional error between two positions by Radar and the Hybrid Navigation System in 9970 chain was about 0.4 miles, and between two positions by Radar and Loran C was about 0.51 miles. The Hybrid Navigation System was therefore more accurate than Loran C System. 3. The positional error between two positions by Radar and Hybrid Navigation System in 5970 chain was about 0.4 miles, and between two positions by Radar and computer simulation of Loran C was about 0.98 miles. Consequently, Hybrid Navigation System was more accurate than computer simulation of Loran C system.

  • PDF