• 제목/요약/키워드: oil-immersed transformer oil

검색결과 55건 처리시간 0.025초

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

지능형 유중가스분석법을 이용한 전력용 변압기 관리시스템 개발 (Development of Power Transformer Maintenance System Using Intelligent Dissolved Gas in Oil Analysis)

  • 선종호;김광화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.87-90
    • /
    • 2004
  • This paper describes development of power transformer maintenance system using intelligent dissolved gases in oil analysis. The used gases are acetylene(C2H2), hydrogen(H2), ethylene(C2H4), methane(CH4), ethane(C2H6), carbon monoxide(CO) and carbon dioxide(CO2). The rule and neural network based gas analysis methods are used for artificial intelligent diagnosis. It is indicated that this program is efficient for diagnosis of oil immersed transformers diagnosis from application of gas analysis data of serviced transformer which has local overheating

  • PDF

유입변압기 중신부 온도상승 예측 및 모니터링 (Temperature-Rising Prediction and Monitoring for an Oil-immersed Power Transformer)

  • 이준엽;이창용;김용한;박성원;윤자홍;남극채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.94-96
    • /
    • 2004
  • In order to observe the thermal behavior of oil immersed power transformers the temperature rise prediction algorithm and monitoring system were developed. The algorithm is formulated into a computer program based on the TNM (Thermal Network Method) which was divided into several elements, and the temperature of each element was calculated according to each time lapse. A monitoring system can show the real time active part temperatures of the transformer under various electric loads and for any types of thermal environment.

  • PDF

154kV 방재형 난연 변압기 냉각특성에 관한 연구 (A Study on the Cooling Characteristic of a 154kV Less-Flammable Power Transformer)

  • 박정호;오원근;하영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.61-64
    • /
    • 2001
  • Demand for development of 154kV Less-Flammable Power transformer is now increasing greatly instead of a oil-immersed transformer for preventing disasters and Less-flammability of substations. The most important point in developing Less-flammable transformer is cooling system. This paper describes the study on cooling characteristic of Less-flammable transformer.

  • PDF

유침 절연에서 전기적 및 열적 열화에 따른 유중가스분포특성 (Characterisrics of Dissolved Gas Distribution in Oil with Thermal and Electrical Degradation in Oil Imersed Paper Insulation)

  • 선종호;이상화;김광화
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.136-144
    • /
    • 2004
  • 본 논문에서는 유침절연에 대한 열열화와 전기적열화 실험을 실시하여 유중가스분석법을 이용한 유침절연의 고장원인 진단에 대한 신뢰성을 향상시키는 방안에 대하여 연구하였다. 유침절연의 고장원인에 대하여 주도가스법과 탄화수소가스의 구성률, CO/$CO_2$비와 같은 진단요소를 단독으로 사용하는 것보다는 진단요소들의 상호관계를 이용하는 것이 유침절연의 고장원인을 신뢰성 있게 진단하는 것으로 나타났다.

배전용 변압기 절연유의 특성 비교 평가 (The Evaluation of Characteristics for Insulating Oil Using the Distribution Transformer)

  • 이병성;박영근;김동명;김필환;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-99
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용 (The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers)

  • 이병성;송일근;이재봉;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발 (The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer)

  • 안용호;박종범;송택상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

국내 유입식변압기의 유중가스분포 특성 (Characteristics of Distribution of Dissolved gases in oil for Domestic Oil Immersed Transformer)

  • 선종호;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.35-38
    • /
    • 2004
  • 본 연구는 국내에서 사용되고 있는 유입식변압기의 유중가스분포 특성에 대해서 설명하고 있다. 정상적으로 국내에서 운전중에 있는 변전용변압기와 발전기승압용 변압기, 산업체에서 사용되고 있는 배전용변압기의 유중가스분석결과로부터 데이터를 얻었다. 분석가스종류는 H2와 C2H2, C2H4, C2H6, CO, CO2, TCG 이며, 분포특성과 각 유중가스진단규격에서 제시하고 있는 진단기준치와의 비교 검토를 수행하였다.

  • PDF

유중 부분방전의 음향검출에 관한 연구 (A Study on the Acoustic Detection of Partial Discharges in Insulation Oil)

  • 길경석;김성욱;박대원;김선재;송재만
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.