• 제목/요약/키워드: oil tube

검색결과 208건 처리시간 0.028초

해양 구조물용 공조덕트 유동 및 구조해석에 관한 연구 (A Study on the Flow and Structural Analysis in an Air Conditioning Duct for Marine Offshore)

  • 이중섭;이병호;진도훈
    • 한국기계가공학회지
    • /
    • 제18권3호
    • /
    • pp.88-93
    • /
    • 2019
  • This study concerns the distributions of flow in an air conditioning duct used for a marine and oil drilling ship. From the results of carrying out flow analysis and structural analysis of a ventilation duct applied to a marine structure, the following conclusion could be gained. The pressure tended to increase as the flow velocity at the inlet increased and the pressure at the inlet increased. It was recognized that the pressure decreased due to the influence of a corrugated tube when it entered and exited from the duct. As a result of structural analysis, a higher train was generated at the corrugated tube compared with the duct. In addition, in the case of the internal pressure of 0.7MPa, which was the designed load, it was found that there was almost no influence as it was within 0.1mm.

형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석 (Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter)

  • 오상우;서동민;안기영;김재우;이문진;전태병;서성규
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권4호
    • /
    • pp.304-309
    • /
    • 2015
  • 해양에서 기름 유출 사고로 인한 오염도를 정량적으로 평가하기 위해서, 사고 현장에서 기름을 직접 탐지할 수 있는 센서의 적용이 필요하다. 여러 형태의 기름 탐지 센서 중에서, 기름 성분에 의한 형광 현상(fluorescence)을 탐지 원리로 하는 센서는 해수 중에 존재하는 기름의 농도를 측정할 수 있으므로 효용성이 높은 장점을 갖고 있다. 그러나 이런 종류의 센서는 기름의 형광 현상을 야기시키기 위해서, 수은 램프(mercury lamp)와 같은 자외선 광원(ultraviolet light source)이 필요하고 다양한 종류의 광학 필터와 광전증배관(photomultiplier tube, PMT)과 같은 광학 센서가 주로 사용된다. 이러한 이유로 형광 측정을 기반으로 하고 있는 센서는 측정 플랫폼의 크기가 크기 때문에 현장에서 원활히 사용하기에 한계가 있으며, 고가의 부품들이 집적되어 있어, 센서의 가격이 높은 단점을 갖고 있다. 이러한 단점을 극복하기 위해서, 본 논문에서는 소형의 크기와 가격 경쟁력을 갖고 있는 형광 광도계 기반의 기름 탐지 센서를 설계하는 방법에 대해서 제시하였다. 형광 광도계의 설계 인자를 파악하기 위한 방법으로, 본 연구에서는 5종의 원유 샘플과 3종의 정제유를 이용하여, 기름의 여기 스펙트럼(excitation spectrum)과 발광 스펙트럼(emission spectrum)을 측정하였다. 여기 스펙트럼과 발광 스펙트럼의 측정을 위해서는 형광 분광기(fluorescence spectrometer)를 이용하였고, 측정된 스펙트럼 자료를 분석하여 형광 광도계(fluorimeter) 설계에 필요한 유종에 따른 공통 스펙트럼 파장 대역을 도출하였다. 본 실험을 통해서 모든 종류의 기름 샘플의 경우, 여기 스펙트럼과 발광 스펙트럼의 최고 값을 갖는 파장의 차이는 약 50 nm인 것으로 파악되었다. 실험 중에서, 여기광의 파장을 365 nm와 405 nm로 고정하였을 경우, 280 nm와 325 nm로 고정하였을 경우에 비해서 최대 발광(emission)의 세기가 작아지는 것을 확인할 수 있었다. 따라서 형광 광도계의 광원 파장을 365 nm 또는 405 nm로 사용할 경우, 광학 센서의 민감도(sensitivity)가 발광되는 빛의 세기를 측정할 수 있도록 설계에 반영해야 할 것으로 판단된다. 본 연구의 실험에서 도출된 결과를 통해서, 기름 탐지를 위한 형광 광도계의 광원, 광학 센서 그리고 광학 필터의 유효 파장 대역을 선택하는데 필요한 설계 인자를 파악할 수 있었다.

Hardware-Oriented Reliability Centered Maintenance for the Diesel Generators of Wolsong Unit 1

  • Bae, Sang-Min;Park, Jin-Hee;Kim, Tae-Woon;Lee, Yoon-Kee;Song, Jin-Bae
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.587-591
    • /
    • 1997
  • The DGs (Diesel Generators) in NPP (Nuclear Power Plant) has been used for the emergency electric power source to shut down the nuclear reactor safely in case of station blackout. The RCM (Reliability Centered Maintenance) has been applied to DGs for increasing the safety of NPP. The structured defects of DG were not remedied by the improvement of maintenance method. As the first stage of RCM, to find the structured defects, its failure modes were searched and analyzed through the ten year maintenance information. The structured defects such as the air compressor, the lubricating oil pressure, and the insufficient load were the root causes of main failures. The air reservoir reinstallation, the lubricating oil tube modification, the load bank installation, and the qualitative instrumentation were the solutions for the hardware oriented RCM of DGs. There remains the software oriented RCM such as the rejection of useless maintenance, the preventive maintenance, the database of maintenance information, and the predictive maintenance.

  • PDF

온간하이드로포밍을 이용한 알루미늄 자동차부품 제조기술 개발 (Development of Manufacturing Technology for Aluminum Automotive part with Warm Hydroforming)

  • 손성만;이문용;김봉준;문영훈;이영선
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 제5회 박판성형 SYMPOSIUM
    • /
    • pp.93-98
    • /
    • 2006
  • Warm forming technology was classified into hot gas forming of using compressible fluid as a nitrogen gas and warm hydroforming of using the incompressible fluid as a thermal oil by using medium fluid. In this study, the aluminum side-rail part was developed with warm hydroforming technology. For the warm hydroforming system, top and bottom die was designed to insert heating cartridge in die cavity and special indirect fluid heating system was designed to heat the thermal oil. As increase the temperature, hydroformability was increased linearly. Aluminum side-rail center part was formed 90% at the internal pressure of 100bar and perfectly formed at 300bar within a moderate temperature. The tube material used for warm hydroforming was a aluminum 6000 series alloy with the diameter of 120mm, thickness of 5mm, length of 1,300mm. Warm hydroformed side-rail center part had 20% of maximum expansion ratio and below 20% of maximum thinning ratio at corner radius. This results were provided to show warm hydroforming possibility for aluminum automotive components.

  • PDF

소결 코팅 파이프의 열전달 성능에 관한 연구 (A Study on the Heat Transfer Performances in Sintered Pipes)

  • 박기호;;김성일;정대헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.436-439
    • /
    • 2008
  • This paper is to research the heat transfer performance of the sintered pipe. Recently, oil prices is to be 127 $ per barrel, we expect higher costs this summer. We promote alternative fuels, after oil and gasoline prices reached record highs. The governments have made efforts to avoid future crisis by continuing the move toward renewable energy and energy saving. In this paper, we have fabricated a sintered pipe, the heat transfer performance of sintered pipe is achieved experimentally. The pipe is copper tube of outer diameter of 15.88 mm, the length of the pipe is 800 mm. Based on the experimental results, it is shown the overall heat transfer coefficient of sintered pipe is increased as compared with that of a straight pipe, is equal as compared with that of a spiral pipe. The overall heat transfer coefficient was $0.075{\sim}0.09\;kW/^{\circ}C$

  • PDF

초임계 영역에서 수평관내 $CO_2$ 열전달과 압력강하 (The heat transfer and pressure drop characteristics of $CO_2$ during supercritical region in a horizontal tube)

  • 이동건;오후규;김영률;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.500-508
    • /
    • 2004
  • The heat transfer coefficients during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments are conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, and a gas cooler(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flow meter. The gas cooler is a counterflow heat exchanger by cooled water flowing in the annulus. The $CO_2$ flows in the horizontal stainless steel tube. which is 9.53mm in O.D. and 7.75mm in I.D. The gas cooler is 6 [m] in length. which is divided into 12 subsections, respectively. The experimental conditions considered in the study are following range of variables : refrigerant temperature is between 20 and $100^{\circ}C$. mass fluxes ranged from 200 to 400kg/($m^2$.s), average pressure varied from 7.5 to 10.0MPa. The main results were summarized as follows : The friction factors of $CO_2$ in the gas cooler show a relatively good agreement with those predicted by Blasius' correlation. The local heat transfer coefficient in the gas cooler has compared with most of correlations, which are the famous ones for forced convection heat transfer of turbulent flow. The results show that the local heat transfer coefficient of gas cooler agrees well with the correlation by Bringer-Smith except that at the region near pseudo critical temperature. while that at the near pseudo critical temperature is higher than the correlation.

초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석 (Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.

Therapeutic effect of oregano essential oil on subclinical bovine mastitis caused by Staphylococcus aureus and Escherichia coli

  • Cho, Byung-Wook;Cha, Chun-Nam;Lee, Soo-Mi;Kim, Mee-Jeong;Park, Ju-Yeon;Yoo, Chang-Yeol;Son, Song-Ee;Kim, Suk;Lee, Hu-Jang
    • 대한수의학회지
    • /
    • 제55권4호
    • /
    • pp.253-257
    • /
    • 2015
  • Oregano (Origanum vulgare) is an aromatic herb belonging to the Lamiaceae family. This study evaluated the therapeutic effect of oregano essential oil (OEO) on clinical bovine mastitis caused by Staphylococcus (S.) aureus and/or Escherichia (E.) coli. Thirty-two quarters from 18 lactating cows with subclinical mastitis were selected from a dairy farm and were divided into 4 groups (8 quarters/group): negative control (CON), positive control (GEN) and two OEO-treated groups (OEO-1 and OEO-2). Each group was intramammarily treated with saline, 10 g/tube of gentamicin ointment, and single and double doses of 0.9 mL OEO ointment twice a day for three days, respectively. After the treatments, physical udder conditions were greatly improved in GEN and OEO groups. In CON group, somatic cell counts (SCCs), number of white blood cells (WBC) and bacteria were increased. However, in OEO groups, SCCs and number of WBC were significantly decreased and S. aureus and E. coli were not detected in milk as compared with those before the treatments as well as GEN group. These results suggest that OEO may be a useful alternative to antibiotics for the control of subclinical bovine mastitis caused by S. aureus and/or E. coli.

나이가 다른 흰쥐에서 식이내 지방수준과 식이횟수가 체내 지방대사에 미치는 영향 (Effect of Age on Liquid Metabolism in Rats Fed Diets with Different Fat Lieval and in Meal Fed Rats)

  • 정호영
    • Journal of Nutrition and Health
    • /
    • 제19권4호
    • /
    • pp.255-265
    • /
    • 1986
  • This study was designed to investigate the effect of age on the lipid metabolism in the rats fed different diets. In experiment A male Wistar rats of 5 weeks of age and of 32 weeks of age were divided into low fat diet groups and high fat-cholesterol groups. The rats were sacrificed 1 week, 2 weeks and 4 weeks after experiment begins. Also after 4 weeks. the rats in low and high fat diet groups were tube-fed 500mg of choelsterol and were sacrified 3 days later. In experiment b, male Wistar rats of 4 weeks of age and of 6 months of age were divided into 2 groups of butter and cron oil groups. And then eachgroup were divided into 2 subgroups ; meal feeding and nibbling groups . Each diet was fed for 4 weeks. In experiment A, age of the rats and experimental diets did not affect the serum cholesterol and triglycerides concentrations were higher in rats fed high fat cholesterol diet than in those fed low-fat or high -fat diets, but age of the animals had no effect on liver lipid content. The weight and cholesterol content of epidymal fat pad, however were higher in adult rats than in young ones regardless of the diets fed. When the rats were challenged with 500mg cholesterol, the rates of increase in serum and hepatic cholesterol level were higher in adult rats compared to young rats regardless of the diets . On the other hand, the rate of increase of small intestinal cholesterol content was lower in adult rats than in young rats. In experiment B, serum cholesterol and triglyceride content were relatively higher in young rats than adult ones. Stored body lipid was higher in adult rats, as judged by epididymal fat pad weight and total carcass lipid. Meal frequency and the kinds of fat in the diet did not affect the serum choelstero concentration . The serum triglyceride levels. however, was higher in butter fed rats thancron oil fed ones. The cholesterol content of live rand epididymal fat pad was lower in butter fed groups than corn oil groups for both young and adult rats, but there was no difference in liver triglycerides livel.

  • PDF

바이메탈을 이용한 자동차용 가스 스프링 구조해석에 관한 연구 (A Study on the Auto-moblie Gas Spring Structural Analysis Using of Bimetal)

  • 박철우;김호윤
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.131-137
    • /
    • 2013
  • Gas springs have been widely used in motor vehicles as well as in most areas of industry. Instead of coil springs, these gas springs are easily operated to extrusion process or compression process the doors because $N_2$ gas with high pressure and oil are charged in tube. Gas spring sustain the constant elasticity change rate in the high reaction force and long stroke, and they have compact design, appearance and an excellent assembling ability to be mounted easily with any applicatory products. By means of these aspects, gas springs have been widely used in stead of coil springs in the over all industries. In this study, using acommonly used program, ANSYS, the basic research about the heat transfer and equivalent stress change of bimetal.