• 제목/요약/키워드: oil transport

검색결과 187건 처리시간 0.028초

A comparison study between the realistic random modeling and simplified porous medium for gamma-gamma well-logging

  • Fatemeh S. Rasouli
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1747-1753
    • /
    • 2024
  • The accurate determination of formation density and the physical properties of rocks is the most critical logging tasks which can be obtained using gamma-ray transport and detection tools. Though the simulation works published so far have considerably improved the knowledge of the parameters that govern the responses of the detectors in these tools, recent studies have found considerable differences between the results of using a conventional model of a homogeneous mixture of formation and fluid and an inhomogeneous fractured medium. It has increased concerns about the importance of the complexity of the model used for the medium in simulation works. In the present study, we have suggested two various models for the flow of the fluid in porous media and fractured rock to be used for logging purposes. For a typical gamma-gamma logging tool containing a 137Cs source and two NaI detectors, simulated by using the MCNPX code, a simplified porous (SP) model in which the formation is filled with elongated rectangular cubes loaded with either mineral material or oil was investigated. In this model, the oil directly reaches the top of the medium and the connection between the pores is not guaranteed. In the other model, the medium is a large 3-D matrix of 1 cm3 randomly filled cubes. The designed algorithm to fill the matrix sites is so that this realistic random (RR) model provides the continuum growth of oil flow in various disordered directions and, therefore, fulfills the concerns about modeling the rock textures consist of extremely complex pore structures. For an arbitrary set of oil concentrations and various formation materials, the response of the detectors in the logging tool has been considered as a criterion to assess the effect of modeling for the distribution of pores in the formation on simulation studies. The results show that defining a RR model for describing heterogeneities of a porous medium does not effectively improve the prediction of the responses of logging tools. Taking into account the computational cost of the particle transport in the complex geometries in the Monte Carlo method, the SP model can be satisfactory for gamma-gamma logging purposes.

Anesthetic and Physiological Effects of Clove oil and Lidocaine-HCl on the Grass Puffer, Takifugu niphobles

  • Gil, Hyun Woo;Lee, Tae Ho;Choi, Cheol Young;Kang, Shin Beom;Park, In-Seok
    • Ocean and Polar Research
    • /
    • 제39권1호
    • /
    • pp.1-11
    • /
    • 2017
  • The aim of this study was to determine the physiological response and the applicable concentration ranges of anesthetic clove oil and anesthetic lidocaine-HCl, and to investigate the synergistic effect of a mixture of these two anesthetics on the in grass puffer (Takifugu niphobles). The anesthesia times decreased and the recovery times increased with increasing concentrations of clove oil and lidocaine-HCl. Applicable concentration ranges for long-term transportation requiring more than 1 hour were 2 ppm for clove oil and 50 ppm for lidocaine-HCl. With mixtures of the two anesthetics, the anesthesia time decreased as the admixture concentration of clove oil and lidocaine-HCl increased. Anesthesia times of experimental groups with the combined anesthetics were shorter than those with the same concentrations of clove oil or lidocaine-HCl alone. Plasma cortisol concentrations were highest at 6 hours in all experimental groups anesthetized with the mixture of clove oil and lidocaine-HCl, while all groups with clove oil or lidocaine-HCl alone had the highest plasma cortisol concentrations at 12 hours. Plasma glucose concentrations were highest at 12 hours in experimental groups anesthetized with the mixture of clove oil and lidocaine-HCl, while groups with clove oil or lidocaine-HCl alone had the highest plasma glucose at 24 hours. The results of this study provide basic information about anesthetics and the synergistic effect of mixtures of anesthetics in this fish species. This information should be useful for aquaculturists who require methods for safe and easy fish handling, and for transporters who require that minimal stress is imposed on fish during transport.

Separation characteristics of particles in a self-rotating type centrifugal oil purifier

  • Pyo, Young-Seok;Jung, Ho-Yun;Choi, Yoon-Hwan;Doh, Deog-Hee;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.147-153
    • /
    • 2014
  • The centrifugal oil purifier is used in an engine for lubrication and to remove impurities. The momentum needed for the rotation of the cylindrical chamber is obtained by jet injections. An impure particle in the oil is separated by the centrifugal forces moving to the inner wall of the rotating cylindrical chamber body. The dust particles are eliminated when the particles are absorbed onto the surface of the inner wall of the chamber body. The flow characteristics and the physical behaviors of particles in this centrifugal oil purifier were investigated numerically and the filtration efficiencies was evaluated. For calculations, a commercial code is used and the SST (Shear Stress Transport) turbulence model has been adopted. The MFR (Multi Frames of Reference) method is introduced to consider the rotating effect of the flows. Under various variables, such as particle size, particle density and rotating speed, the filtration efficiencies are evaluated. It has been verified that the filtration efficiency is increased with the increments in the particle size, the particle density and the rotating speed of the cylindrical chamber.

345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발 (The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer)

  • 안용호;박종범;송택상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

운반체 함침 유화액막에 의한 폐수중 크롬(VI)의 이동속도 (Tansport Rate of Chromium ion from Waste Water through the Liquid Surfactant Membrane Containing Carrier)

  • 우인성;김경호;이상진;강안수;최세영
    • Elastomers and Composites
    • /
    • 제23권1호
    • /
    • pp.11-17
    • /
    • 1988
  • The transport of chromium(VI) ion from waste water through the liquid surfactant membrane containing tri-n-octylamine as a carrier, was analyzed by a slab model and was investigated through experiments. For the experiment of membrane stability, concentrations of surfactant and liquid paraffin oil were analyzed. Extraction experiments were carried out to observe the effect of system variables, such as concentrations of carrier, and initial chromium(VI) ion in external aqueous phase at $25^{\circ}C$. It is concluded that the most stable formation of liquid membrane emulsion was obtained when surfactant concentration is above 3 wt.% and liquid paraffin oil concentration is 50 vol.%. The theoretical equation on the transport of chromium(VI) ion agreed well with the experimental results.

  • PDF

A new method for ship inner shell optimization based on parametric technique

  • Yu, Yan-Yun;Lin, Yan;Chen, Ming;Li, Kai
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권1호
    • /
    • pp.142-156
    • /
    • 2015
  • A new method for ship Inner Shell optimization, which is called Parametric Inner Shell Optimization Method (PISOM), is presented in this paper in order to improve both hull performance and design efficiency of transport ship. The foundation of PISOM is the parametric Inner Shell Plate (ISP) model, which is a fully-associative model driven by dimensions. A method to create parametric ISP model is proposed, including geometric primitives, geometric constraints, geometric constraint solving etc. The standard optimization procedure of ship ISP optimization based on parametric ISP model is put forward, and an efficient optimization approach for typical transport ship is developed based on this procedure. This approach takes the section area of ISP and the other dominant parameters as variables, while all the design requirements such as propeller immersion, fore bottom wave slap, bridge visibility, longitudinal strength etc, are made constraints. The optimization objective is maximum volume of cargo oil tanker/cargo hold, and the genetic algorithm is used to solve this optimization model. This method is applied to the optimization of a product oil tanker and a bulk carrier, and it is proved to be effective, highly efficient, and engineering practical.

공기부양 이송시스템 개념설계를 위한 전산유동해석 (CFD Analysis for Concept Design of Air Levitation Transport System)

  • 장혁수;박영재;장윤석;최재붕;김영진;천풍환;공재연
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.81-82
    • /
    • 2006
  • Conveyor-type transporters have been widely used as a typical delivery system of semi-conductor, FPD and other IT-related products. However, as the IT-product is getting larger in size and higher in resolution, several problems are caused by mechanical contacts between the transporter and target object. In this context, recently, lots of efforts are being devoted for development of various contact-free handling systems to get rid of deffets and oil contaminations. The objectives of this paper are to characterize suspension mechanisms and to investigate air flow effects on air levitation transport system. For this purpose, a series of CFD analyses were carried out and the simulation data showed a good agreement with the corresponding experimental ones. It is anticipated that the promising result can be used as a basis for concept design of the transport system.

  • PDF

국내 철도부문의 활동도 자료에 따른 온실가스 배출량 비교 연구 (Comparison of GHG Emission with Activity Data in Korean Railroad Sector)

  • 이재영;이영호;김용기;정우성;김희만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.861-864
    • /
    • 2011
  • Since national GHG reduction target by 2020 has been presented in Korea, the role of railroad has been reinforced within transport system due to the allocation of reduction target into sector. So, it is necessary to manage activity data systematically for the calculation of GHG emission in railroad. Now, the activity data of diesel consumption for NIR(National Inventory Report) are provided from oil supply and demand statistics. On the other hands, the activity data collected directly from railroad operating companies are used for GHG & Energy Target Management Act. This study aimed to assess the GHG emissions using two kinds of activity data related to the diesel consumption of railroad in 2009 and 2010. As a result, GHG emissions based on oil supply and demand statistics was 636 thousands ton $CO_{2e}$, but the activity data collected from railroad operating companies showed 649 thousands ton $CO_{2e}$ in 2009. Also, the gap of $CO_{2e}$ emission was increased in 2010. These trends were caused because oil supply and demand statistics included total diesel sales volume during 1 year and the activity data collected from railroad operating companies were the amount of diesel consumption only at railcar operation and maintenance step. In conclusion, it is important to develop the management and verification system of activity data with high reliability to substitute oil supply and demand statistics in railroad sector.

  • PDF

Lymphatic Delivery of Oral Anticancer Tegafur by Emulsion Formulations

  • Lee, Yong-Bok;Koh, Ik-Bae
    • Journal of Pharmaceutical Investigation
    • /
    • 제23권3호spc1호
    • /
    • pp.19-30
    • /
    • 1993
  • The influence of emulsion type of tegafur, an oral anticancer agent, on lymphatic transport was studied in rats. The water-in-oil-type of emulsion and the oil-in-water-type emulsion of tegafur each in 50 mg, calculated in terms of tegafur, were prepared by adding tegafur aqueous solution to sesame oil containing hydrogenated castor oil following ultrasonic treatment, and then the prepared emulsions and aqueous solution as a comparative formulation were administered orally to rats (50 mg/5 ml/kg). The concentration levels of tegafur in plasma of femoral artery and lymph from thoracic duct cannula were measured simultaneously along a time course after administration and the pharmacokinetic parameters were investigated. At the same time, we examined the above described factors of 5-FU which is known as an active metabolite of tegafur. In comparison with tegafur solution, AUC and mean residence time of plasma tegafur were significantly increased in w/o-emulsion but significantly decreased in o/w-emulsion. Lymph flow rates were similar in both solution and w/o-emulsion but half in o/w-emulsion. Ratios between area under the lymph and plasma concentration time curves were always less than 1 reflecting the passive lymphatic delivery after oral administration of the prepared tegafur emulsions, but those to the 5-FU in the case of w/o-emulsion were more than 1. These results suggested that lymphatic delivery of tegafur by w/o-emulsion was more effective than that by o/w-emulsion due to its differences of formation ability of chylomicrons.

  • PDF

The Effect of Emission Control Using Electrolytic Seawater Scrubber

  • An, Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.373-377
    • /
    • 2009
  • It is well known that SOx and NOx concentration has a considerable influence on the $N_2O$ emission of the greenhouse gas properties. The quantity of SOx generated during combustion, on fuel specific basis, is directly related to the sulfur content of the fuel oil. However, restricting the fuel oil sulfur content is only a partial response to limiting the overall quantity of SOx emissions, as there remains no over control on the fuel oil consumption other than the commercial pressure which have always directed the attention. This study was carried out as a new basic experiment method of emission control, manly targeted to the vessel. In the experiment, where the scrubbing was achieved through spray tower with high alkaline water made from the electrolysis of seawater, the combined action was to neutralize the exhaust gases (SOx, PM, CO etc.), dilute it, and wash it out. The results showed that SOx reduction of around 95 percent or over could be achieved when using in the high alkaline water, and also leaded to a reduction in the stability of the each pollutant components including the PM (Particulate Matter). The results suggest that the seawater electrolysis method has a very effective reduction of emissions without heavy cost, or catalysts particularly on board.