• Title/Summary/Keyword: oil outlet

Search Result 89, Processing Time 0.027 seconds

Characteristics of Temperature Control by Hot-gas Bypass Flow Rate on Industrial Water Cooler (핫가스 바이패스 유량에 따른 산업용 냉각기의 온도제어 특성)

  • Baek, Seung-Moon;Choi, Jun-Hyuk;Byun, Jong-Yeong;Moon, Choon-Geun;Lee, Ho-Saeng;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1129-1136
    • /
    • 2009
  • The paper presents the performance characteristics for a cooling system using EEV. The water cooler was used to reduce thermal deformation and contraction due to high speed of machine tools and the EEV was used for capacity control for water cooler. The apparatus was designed for hot-gas bypass system which a hot-gas can flows from outlet of compressor to the inlet of evaporator. This experiment is the intermediary study for precise temperature control through PID control. The results show that the evaporator pressure increased and refrigeration capacity decreased as the EEV opening step of hot-gas bypass increased. These results can be used as basic data for the design of effective water cooler.

Detailed Design for 25bar-class Biogas Compression Supplying System (25BAR급 바이오가스 고압 압축공급시스템 상세설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yun, Eun-Young;Lee, Jung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

Thermohydrodynamic Lubrication Analysis of Surface-Textured Parallel Slider Bearing: Effect of Dimple Depth (Surface Texturing한 평행 슬라이더 베어링의 열유체윤활 해석: 딤플 깊이의 영향)

  • Park, TaeJo;Kim, MinGyu
    • Tribology and Lubricants
    • /
    • v.33 no.6
    • /
    • pp.288-295
    • /
    • 2017
  • In order to improve the efficiency and reliability of the machine, the friction should be minimized. The most widely used method to minimize friction is to maintain the fluid lubrication state. However, we can reduce friction only up to a certain limit because of viscosity. As a result of several recent studies, surface texturing has significantly reduced the friction in highly sliding machine elements, such as mechanical seals and thrust bearings. Thus far, theoretical studies have mainly focused on isothermal/iso-viscous conditions and have not taken into account the heat generation, caused by high viscous shear, and the temperature conditions on the bearing surface. In this study, we investigate the effect of dimple depth and film-temperature boundary conditions on the thermohydrodynamic (THD) lubrication of textured parallel slider bearings. We analyzed the continuity equation, the Navier-Stokes equation, the energy equation, and the temperature-viscosity and temperature-density relations using a computational fluid dynamics (CFD) code, FLUENT. We compare the temperature and pressure distributions at various dimple depths. The increase in oil temperature caused by viscous shear was higher in the dimple than in the bearing outlet because of the action of the strong vortex generated in the dimple. The lubrication characteristics significantly change with variations in the dimple depths and film-temperature boundary conditions. We can use the current results as basic data for optimum surface texturing; however, further studies are required for various temperature boundary conditions.

Diesel Desulfurization Reactor Design for Fuel Cell by Computational Fluid Dynamics (CFD 모델링을 통한 연료전지용 디젤의 흡착탈황 반응기 디자인)

  • Kwon, Sang Gu;Liu, Jay;Im, Do Jin
    • Clean Technology
    • /
    • v.21 no.4
    • /
    • pp.229-234
    • /
    • 2015
  • Recently, there are increasing numbers of study regarding hydrogen fuels but researches on desulfurization of diesel are rare. In this study, we performed diesel desulfurization reactor design by computation fluid dynamics simulation. By analyzing the change in flow and sulfur concentration at the outlet according to the changes in flow rate, reactor length, and reactor diameter, we have found the minimum catalyst performance for the given flow rate condition and the relation between the reactor performance and the reactor size and shape. We also studied the effects of permeability of the packed bed on the flow and sulfur concentration distribution. The present work can be utilized to design a diesel desulfurization reactor for a fuel cell used in ships. Furthermore, the present work also can be used to design low sulfur diesel supply in oil refineries and therefore contribute to the development of clean petrochemical technology.

A New Set of Capillary Tube Selection Charts for R-22 in Consideration of the Roughness Effect (조도를 고려한 R-22용 모세관 선정 선도)

  • Kim, C.N.;Hwang, U.P.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.681-693
    • /
    • 1995
  • A new set of capillary tube selection charts for R-22 is proposed. The set of charts takes into account of the roughness effect on the mass flow rate. For this purpose, a set of numerical model is developed and a series of experiments is conducted to verify the numerical model. A numerical model is used to calculated the mass flow rate for several sets of tube diameter, length, inlet pressures and degree of subcooling. The outlet of the tube is controlled to be at critical condition. The experimental flow rate is compared with calculated values. The calculated values are consistently less than the experimental ones except for the flow rate range below 40kg/hr. The deviation is within 10---. Based on the nunmerical model and results of experiments, the set of capillary tube selection charts for R-22 is constructed. The set of charts consists of standard capillary tube chart(L=2030mm, d=1.63mm, ${\varepsilon}=2.5{\mu}m$), non -standard flow factor(${\phi}_1$) chart, and non-standard roughness factor(${\phi}_2$) chart. The mass flow rate, flow factor, and the roughness factor are defined respectively as; $\dot{m}={\phi}_1{\phi}_2\dot{m}_{standard}\\{\phi}_1=\frac{\dot{m}(L,\;d,\;\varepsilon_{standard})}{\dot{m}_{standard}(L_{standard},\;d_{standard},\;{\varepsilon}_{standard})}\\{\phi}_2=\frac{\dot{m}(L_{standard},\;d_{standard},\;{\varepsilon})}{\dot{m}_{standard}(L_{standard},\;d_{standard},\;{\varepsilon}_{standard})}$.

  • PDF

A Study of Alkali Metal Vapor Adsorption Behavior by Using Pressurized Reactor (가압반응기를 이용한 알칼리금속증기 흡착특성에 관한 연구)

  • 전수한;최병철;김형택
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.114-121
    • /
    • 2002
  • Alkali metal compounds existed in original coal or sorbents are exhausted as vapor or small particle at the outlet of combustor when operating PFBC power plant. These compounds can be removed with dust removal equipment, but total generation efficiency will be decreased because of lower operating temperature of dust removal equipment. Alkali metal contained in vapor phase is initially deposited onto turbine blade results in serious corrosion. The concentration of alkali vapor in the PFBC flue gas is 20∼40 ppm which is dependent on mineral characteristics and composition as well as operating condition of PFBC. However, the allowance limit of alkali metal vapor is assigned as less than 50 ppb for gas turbine when coal or oil is used as fuel. Therefore, alkali metal vapor in PFBC or IGCC process should be removed by solid sorbents to prevent corrosion of turbine blade and improve plant efficiency. In the present investigation, powder of Bauxite, Kaolinite and Limestone is used in the preparation of cylinder-type pellet which is inserted into the pressurized alkali removal reactor for the alkali absorption experiment. Experimental results showed that the alkali removal efficiency in the order of Bauxite, Kaolinite and Limestone. Alkali vapor removal efficiency is related with reaction temperature, porosity of pellet and alkali vapor concentration of flue gas.

Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse (시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.162-166
    • /
    • 2004
  • Air temperature variation along the length of the air duct in an air-heated plastic greenhouse was large, 13 ~ 15$^{\circ}C$ between the front and the rear side of a greenhouse. To reduce this temperature variation, a new PE-film air duct having a small duct inside a large duct (double duct) was developed. This double duct was consisted of an inner duct with air outlets at a 0.15 m interval and an outer duct with air outlets at a 2.5 m interval. Diameters of the air outlet holes were 7, 15, and 35 cm from the front to the end of the inner duct film, while identical 10 cm holes were used on the outer duct film. As a result, air temperature was $46^{\circ}C$ at the beginning side and $47^{\circ}C$ at the ending side, while the conventional single duct had $53^{\circ}C$ at the beginning point and $38^{\circ}C$ at the ending point with a variation of $15^{\circ}C$. Height of a cucumber crop grown in a greenhouse with the new double air duct system was 65.5 cm, 14% increase as compared to that in a greenhouse with a conventional air duct system. Total fruit yield per l0a greenhouse in a greenhouse with the new double air duct system was 4,616 kg, which was 17% greater than that in a greenhouse with a conventional air duct system. Amount of heating oil consumption during March 3 to April 24, 2002 was 3,233 L per l0a greenhouse with the new double air duct system, which was 13% less than that with a conventional air duct system.

A Study on IPA-based Competitiveness Enhancement Measures for Regular Freight Service (IPA분석을 이용한 정기화물운송업의 경쟁력 강화방안에 관한 연구)

  • Lee, Young-Jae;Park, Soo-Hong;Sun, Il-Suck
    • Journal of Distribution Science
    • /
    • v.13 no.1
    • /
    • pp.83-91
    • /
    • 2015
  • Purpose - Despite the structural irrationality of multi-level transportation and the oil price rise, the domestic freight transportation market continues to grow, mirroring the rise in e-commerce and resultant increase in courier services and freight volumes. Several studies on courier services have been conducted. However, few studies or statistics have been published regarding regular freight services although they have played a role in the freight service market. The present study identifies the characteristics of regular freight service users to seek competitiveness enhancement measures specific to regular freight services. Research design, data, and methodology - IPA is a comparative analysis of the relative importance of and satisfaction with each attribute simultaneously. This study used IPA because it facilitates the process of analyzing importance and performance, deriving implications and a visual understanding of results. To enhance the competitiveness of regular freight services, this study surveyed its current users regarding the importance of the regular freight service factors. A total of 200 copies of a questionnaire were circulated and 190 copies were returned. In addition to demographics, respondents answered questions about the importance of and satisfaction with services on a 5-point Likert scale. Excluding 3 inappropriate copies, 187 out of 190 copies were analyzed. PASW Statistics 18 was used for statistical analysis. A total of 20 question items were selected for the service factors presented in the questionnaire based on the 1st pilot survey and previous studies. Results - According to the IPA performed to compare the importance of and satisfaction with service factors, both importance and satisfaction are high in the 1st quadrant, which involves the economic advantage of using regular freight services, quick arrival at destinations, weight freight handling, and less time constraints on freight receipt/dispatch. This area requires continuous management. Satisfaction is higher than importance in the 2nd quadrant, which involves the adequacy of freight, cost savings over ordinary courier services, notification on freight arrival, and freight tracking information. This area requires intensive investment and management. Satisfaction is lower than importance in the 3rd quadrant, involving the credit card payment system, courier delivery service, distance to freight handling sites, easy access to freight handling sites, and prompt problem solving. This area requires further intensive management. Both importance and satisfaction are low in the 4th quadrant, involving the availability of collection service, storage space at freight handling sites, kindness of collection/delivery staff, kindness of outlet staff, and easy delivery checks. This area is a set of variables should be excluded from priority control targets. Conclusions - Based on the IPA, service factors that need priority controls because of high importance and low satisfaction include the credit card payment system, delivery service, distance to freight handling sites, easy access to freight handling sites, and prompt problem solving. The findings need to be applied to future marketing strategies for regular freight services and for developing competitiveness enhancement programs.

A Study on Reported Status and Management Plan of Marine Facilities in Korea 1. On the Basis of Nationwide Status of Marine Facilities (국내 해양시설의 신고 현황과 관리 방안에 관한 연구 1. 전국의 해양시설 현황을 중심으로)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.3
    • /
    • pp.269-274
    • /
    • 2010
  • Present state of nationwide marine facilities reported to Minister of Land, Transport and Maritime Affairs{MLTM} in Korea for two years 2008 and 2009 was analyzed, and management plan was proposed in this study. As of the end of 2009, total number of nationwide marine facilities was reported to be 672 and to be scattered along the coasts all over the nation. 124 marine facilities reported to Masan regional maritime affairs and port office occupied 18.5% of total nationwide number. 69 marine facilities reported to Mokpo regional office and 69 marine facilities reported to Pohang regional office occupied 10.3%, respectively. 181 marine facilities reported to Busan and Masan regional offices occupied 26.9%, meaning that about a quarter of total nationwide marine facilities concentrated in Southeastern Sea of Korea centering around Busan and Masan. 320 oil and noxious liquid substances storage facilities occupied 47.6% of total nationwide number. 11 pollutant storage facilities occupied 1.6%. 178 ship construction, repair and scrap facilities occupied 26.5%. 7 cargo handling facilities occupied 1.0%. 12 waste storage facilities occupied 1.8%. none of marine facilities for tourism, housing and restaurant were reported. 88 water intake and outlet facilities occupied 13.1%. 37 fishing spots at play occupied 5.5%. 13 other marine facilities occupied 1.9%. 6 integrated marine science base facilities occupied 0.9% of total nationwide number. The guidance and the public relation for national report system of marine facilities, the improvement of national report system and management plan, the advancement and complement of national report affairs-handling guides, and the voluntary participation in national report system and the performance of duties by the owners of marine facilities were proposed for better management plan of marine facilities.