• Title/Summary/Keyword: oil flow rate

Search Result 357, Processing Time 0.029 seconds

A Study on the flow of Ball Check valve in the Oil Jet for cooling the Piston (피스톤 냉각용 Oil Jet내 볼 체크 밸브 주위 유동 연구)

  • Kwon, J.H.;Jung, H.Y.;Lee, J.H.;Choi, Y.H.;Lee, Y.W.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.195-199
    • /
    • 2005
  • As vehicles are recently becoming more important in our life, the study for engine capacity has been conducted for many years. Specially, the study on lubrication in the engine is needed to develop engine capacity. The role of lubrication is to reduce fraction, manage the temperature and protect from corrosion etc. At the view point of the engine, lubrication and cooling of the engine have an effect on the life and efficiency, so we have to study this problem. Ball check valve is located in the inlet of the Oil Jet. Ball check valve is used to control the flow rate of the engine oil, which cools and lubricates the engine. Flow rate at the oil jet is very important, so the study for this problem is needed to conduct researches. The point of this study is to compute the flow rate and the flow in oil jet. The results of this study is that the mass flow rate is satisfied with the research which is obtained at the experiment.

  • PDF

Conversion of Jatropha Oil into Biodiesel in Continuous Process Using Alkali and Mixed Catalysts (연속공정에서 알칼리 및 혼합촉매를 사용한 자트로파유의 바이오디젤화)

  • Hyun, Young-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.394-399
    • /
    • 2009
  • The esterification of palmitic acid in Jatropha Oil using 8wt% p-TSA catalyst was done at the 1:8 molar ratio of oil to methanol and $65^{\circ}C$. The conversion of palmitic acid appeared to be 95.3% in 60min. After that, the continuous transesterification of the oil using 0.5wt% KOH, 0.8wt% TMAH mixed catalyst[40vol% KOH(0.5wt%) + 60vol% TMAH(0.8wt%)] and 1.1wt% TMAH was conducted with the flow rates and the molar ratios at $65^{\circ}C$. The overall conversion of Jatropha Oil increased with the decrease of flow rate and showed 95.6% with 9ml/min of flow rate at the 1:8 molar ratio of oil to methanol and $65^{\circ}C$. But it showed 87% with 15ml/min of flow rate at the same conditions. The recovery of methanol(%) appeared to be 86% at the 1:8 molar ratio of oil to methanol, mixed catalyst and $65^{\circ}C$.

A Numerical investigation of Oil Jet in an Engine Piston (피스톤 냉각용 Oil Jet 유동 수치해석)

  • Li, Li;Kwon, Ji-Hyuk;Jung, Ho-Yun;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.33-34
    • /
    • 2005
  • The internal state of an automotive engine is very severe. A piston exposes burnt gas of over $2000^{\circ}$ nd is shocked by high pressure at the time of explosion. Furthermore strong friction is caused by high speed motion. A study on the cooling of the piston requires because the cooling and lubrication of the piston has an effect on the life and efficiency of engine directly. The previous system of oil jet cooled only the bottom of the piston. In order to improve the cooling efficiency, the oil gallery is made inside the piston, and oil flows into the oil gallery. The flow rate of oil at the entrance of oil gallery is important because of the cooling efficiency. The purpose of this study is the investigation of fluid flow characteristics of oil jet and flow rate into the oil gallery.

  • PDF

Hydrodynamic Design of Thrust Ring Pump for Large Hydro Turbine Generator Units

  • Lai, Xide;Zhang, Xiang;Chen, Xiaoming;Yang, Shifu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • Thrust-ring-pump is a kind of extreme-low specific speed centrifugal pump with special structure as numerous restrictions from thrust bearing and operation conditions of hydro-generator units. Because the oil circulatory and cooling system with thrust-ring-pump has a lot of advantages in maintenance and compactness in structure, it has widely been used in large and medium-sized hydro-generator units. Since the diameter and the speed of the thrust ring is limited by the generator set, the matching relationship between the flow passage inside the thrust ring (equivalent to impeller) and oil bath (equivalent to volute) has great influence on hydrodynamic performance of thrust-ring-pump. On another hand, the head and flow rate are varying with the operation conditions of hydro-generator units and the oil circulatory and cooling system. As so far, the empirical calculation method is employed during the actual engineering design, in order to guarantee the operating performance of the oil circulatory and cooling system with thrust-ring-pump at different conditions, a collaborative hydrodynamic design and optimization is purposed in this paper. Firstly, the head and flow rate at different conditions are decided by 1D flow numerical simulation of the oil circulatory and cooling system. Secondly, the flow passages of thrust-ring-pump are empirically designed under the restrictions of diameter and the speed of the thrust ring according to the head and flow rate from the simulation. Thirdly, the flow passage geometry matching optimization between thrust ring and oil bath is implemented by means of 3D flow simulation and performance prediction. Then, the pumps and the oil circulatory and cooling system are collaborative hydrodynamic optimized with predicted head-flow rate curve and the efficiency-flow rate curve of thrust-ring-pump. The presented methodology has been adopted by DFEM in design process of thrust-ring-pump and it shown can effectively improve the performance of whole system.

Assessment of Potential Utility of Subcritical Water for Remediation of Crude Oil Contaminated Soil (원유오염토양의 아임계수를 통한 정화 가능성 평가)

  • Jeong, Yeon-Jae;Jo, Young-Tae;Islam, Mohammad Nazrul;Park, Seong-Jae;Jung, Sun-Kook;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.48-56
    • /
    • 2017
  • Although various methods have been investigated for treatment of crude oil contaminated soil, more researches are still required to preserve soil environment. This study investigated the potential utility of subcritical water in remediation of crude oil contaminated soil under various experimental conditions including temperature ($150-300^{\circ}C$), flow rate (1.0-2.0 mL/min) and extraction time (60-120 min). The removal rate of crude oil gradually increased with increasing temperature and time. After treatment at $200^{\circ}C$ and $300^{\circ}C$ for 60 min, the remaining concentration of crude oil met the Kuwait standard clean-up level (10,000 mg/kg) and the Korean standard level (2,000 mg/kg), respectively. The removal efficiency of crude oil increased from 77.8% to 88.4% with increasing extraction time from 60 to 120 min at $250^{\circ}C$. A decreasing rate of oil removal was observed as flow rate increased, possibly due to channeling flow occurred within the soil body at higher flow rate condition. Overall, the results revealed that subcritical water extraction process could be feasible for remediation of crude oil contaminated soil, and the relative effect of parameters on the oil removal was in the order of temperature > time > flow rate.

Prediction of Oil Lifetime due to Overheating of Oil and Bearing Housing in a Pump (펌프 베어링하우징에서 베어링과 오일의 과열 및 오일수명 예측)

  • 한상규;강병하;이봉주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.408-413
    • /
    • 2004
  • An experimental study has been carried out to investigate overheating of oil and bearing housing during pump operation. This problem is of particular interest in the pre diction of lifetime and failure of pump. Transient variation of oil temperature as well as bearing housing temperature is measured to study the effect of oil viscosity, oil amount, and discharge flow rate of pump. It is found that optimal oil quantity as well as proper viscosity of oil is required to keep the safe temperature level of oil and bearing housing in a pump. The oil temperature at steady state is almost not affected by discharge flow rate in the range of discharge flow rates considered in the present study.

Hydrostatic Bearing Characteristics of Slipper in Piston Pump . Motor (액셜 피스톤 펌프 . 모터의 피스톤 구면부 정압 윤활특성)

  • 박경민;김종기;오석형;송규근;정재연
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.186-193
    • /
    • 2001
  • In the high pressure state, the leakage flow rate of hydraulics is one of serious problems and the great reason to decrease the volume efficiency. In this paper, I tried to clarify tribology characteristics for the slipper hydrostatic bearing in swash plate type axial piston pumps and motors by means of experiment . I measured the leakage flow rate between swash plate and piston shoe with change the supply pressure and oil temperature at a swash plate angle of 0。 . And I also investigated the slipper pocket pressure and calculated oil film thickness for theoretical method. So. 1 have analyzed the tribology characteristics of hydrostatic bearing for leakage flow rate and oil film thickness with oil temperature and supply pressure.

  • PDF

The Effects of Oil on Refrigerant Flow through Capillary Tubes (냉동기유가 모세관내의 냉매유량에 미치는 영향)

  • 홍기수;황일남;민만기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.791-801
    • /
    • 2000
  • An experimental study was conducted to analyze the effects of oil on refrigerant flow through adiabatic capillary tubes, and to develop a model for mass flow rates of refrigerant/oil mixture at various capillary tubes and flow conditions. Mass flow rates and the profiles of the pressures and temperatures along the capillary tubes was obtained with the oil concentration of R-22/SUNISO 4GS oil mixture at various test conditions. The flow trends as a function of geometry and flow conditions for pure refrigerant and refrigerant/oil mixture were similar in adiabatic capillary tubes. Mass flow rate of the refrigerant/oil mixture was less than that of pure refrigerant at the same test conditions.

  • PDF

A Study on Effects of Oil Aeration Level on Engine Lubrication System by using Computer Program (컴퓨터 프로그램을 이용한 엔진오일 내 공기함량 변화가 엔진윤활시스템에 미치는 영향 연구)

  • 전상명;박영환;장시열
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.198-208
    • /
    • 2001
  • A Parametric study based on a computer analysis of the lubrication system of a four-cylinder gasoline engine is illustrated. Through the parametric study, the effects of various aeration levels on the change of oil flow rate and pressure are investigated. Also, at high oil temperature and low engine speed, the effect of oil aeration level on oil flow characteristics in lubrication system is investigated. The illustrated results may give to designers the guide lines of oil aeration level for the safe design of engine lubrication systems in terms of minimum pressure at crank oil bore.

Evaluation of Engine Lubrication System for Adapting Variable Cam Timing System (VCT탑재를 위한 엔진윤활시스템 평가)

  • Yun Jeong-Eui
    • Tribology and Lubricants
    • /
    • v.22 no.1
    • /
    • pp.14-19
    • /
    • 2006
  • VCT(Variable Cam Timing) system is one of very useful engine components to improve fuel economy and overcome emission regulation etc. In order to adapt the VCT to a base engine, many design mod ifications in the mechanical and lubrication fields are required. Especially, because the VCT performance itself depends on supplied oil flow rate and pressure, it is very important to evaluate the engine lubrication system in a viewpoint of supplied oil flow rate and pressure. In this paper, unsteady transient flow network analysis on the engine oil circuit system was carried out to do this.