• Title/Summary/Keyword: office room

Search Result 288, Processing Time 0.03 seconds

A Fundamental Study of Optimization to Control on Height of Roller Shade in Office Building through Mock-up Experiment (Mock-up 실험을 통한 사무소 건축물의 Roller Shade 높이 제어 최적화에 관한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.148-153
    • /
    • 2008
  • An inflow of daylight to the room offers comfortable view environment, psychological and physical security to people in the room and there are merits such as a work efficiency and energy saving. But, it has many problems as an excessive direct sunlight, cooling and heating. We can expect to have energy saving effect for illumination with comfortable view environment creation through control on height of roller shade. This study will be a used a fundamental approach to control on height of roller shade to changing daylight.

  • PDF

Effects of Different Lighting Systems on interior perception - Focus on the Individual office room - (실내공간 인식에 있어서 조명방법 차이에 대한 효과 - 개인 사무실을 중심으로 -)

  • 배강원
    • Korean Institute of Interior Design Journal
    • /
    • no.27
    • /
    • pp.51-56
    • /
    • 2001
  • The idea to improve the quality of lighting design in interior spaces has gained importance in the last years. This experimental study concentrates on the quality of lighting and the relation between lighting arrangements and perception. A individual office room having four different lighting arrangements was prepared and the differences between the perception of the participants under each lighting arrangement was evaluated. The results suggested that lighting system and arrangements affect interior perception. Wall washing enhanced the impressions of clarity and order, cove lighting enhanced the ceiling higher respectively and other and tungsten-halogenated uplighting made the same space relaxing, private and pleasant.

  • PDF

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.

Analysis on Reduction Effect of Hydraulic Turbine Dynamo Noise using Acoustic Simulation (음향시뮬레이션을 이용한 수차 발전기소음의 저감효과 분석)

  • Jung, Eun-Jung;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.248-252
    • /
    • 2007
  • As Waterpower Generation generates electricity using the difference of altitude of water, also let the turbine revolves through water pipe, at this time the revolving turbine causes exceedingly huge noise. Accordingly, not only those workers in the hydraulic turbine dynamo room are suffering the difficulties in mutual communication, but also those workers in the adjacent office are enduring the obstruction to the business due to the noise. Therefore, this Study has analyzed the reduction effect on the noise of hydraulic turbine dynamo room utilizing computer simulation, through the preceding research with the optimized model for architectural acoustic factor of the hydraulic turbine dynamo room. It is considered that such research result could be applied as the useful material for improvement of acoustic performance and noise-reduction effect at other similar hydraulic turbine dynamo room in the future.

  • PDF

A Study on the Using Trends of Interior Materials in Current Medium Size Office Building in Seoul (최근 서울시 중형 OFFICE 건물의 실내재료의 사용경향에 관한 연구)

  • 김은중
    • Korean Institute of Interior Design Journal
    • /
    • no.23
    • /
    • pp.19-25
    • /
    • 2000
  • This study aims by analysing the interior design elements trends of current medium size office buildings in Seoul. The analysing objects are ceiling, floor, wall, and illumination plan of current office buildings. Analysing tools are finishing material and color of each part. Analysing areas are lobby area, deskwork area, conference area, welfare area, public area(rest room, corridor, stair). The interior design elements of lobby shows a lots of different features then the other areas in ceiling, floor, and wall design. Such difference appears at finishing material especially, and the coloring is more splendorous then the other areas. Desk work area and conference area have similar characteristics in finishing materiors and colors, and they usually follow the needs of function. Walfare area shows more splendorous feature then deskwork and conference area, and designed by various materials and colors. Public area also shows very active design concept then past times.

  • PDF

The Indoor Environmental Quality Improving and Energy Saving Potential of Phase-Change Material Integrated Facades for High-Rise Office Buildings in Shanghai

  • Jin, Qian
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.197-205
    • /
    • 2017
  • The conflict between indoor environmental quality and energy consumption has become an unneglectable problem for highrise office buildings, where occupants' productivity is highly affected by their working environment. An effective Façade, therefore, should play the role of an active building skin by adapting to the ever-changing external environment and internal requirements. This paper explores the energy-saving and indoor environment-improving potential of a phase-change material (PCM) integrated Façade. Building performance simulations, combined with parametric study and sensitivity analysis, are adopted in this research. The result quantifies the potential of a PCM-integrated Façade with different configurations and PCM properties, taking as an example a south-oriented typical office room in Shanghai. It is found that a melting temperature of around $22^{\circ}C$ for the PCM layer is optimal. Compared to a conventional Façade, a PCM-integrated Façade effectively reduces total energy use, peak heating/cooling load, and operative temperature fluctuation during the periods of May-July and November-December.

A Study on Education Example for Office Design (업무공간디자인 교육사례 연구)

  • Byun, Dae-Joong
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.225-226
    • /
    • 2005
  • In early 20th century, This study focus on exploration of a education for office design This class is focused on planning an office space. Selection of the right places, Setting a concept room plans, and such are studied along with systematically analyzing spaces. Applying concepts, interior plans, interior elements, color and selection of materials are introduced and developed into systematical plans. And the students produce efficiently a portfolio by complementing and/or developing the visual materials and readjusting all the concept of the accomplished assignments during this course that were presented visually by applying techniques of presentation leaned majoring in interior design, in an aesthetical and creative ways.

  • PDF

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

A Fatal Case Involving Venlafaxine Intoxication

  • Baeck, Seung-Kyung;Jeon, Seok-Hoon;Kim, Sun-Chung;Kim, Dong-Woo
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.121.3-122
    • /
    • 2003
  • This report describes the fatal case of a 13-year-old middle school girl(MSG) whose cause of death might be attributed to a intoxication involving Venlafaxine(VEN). MSG's mother had the history of depression for 11 years. She and her daughter were found dead in the same room of their apartment, with hanged herself. We analyzed the postmortem of MSG which were requested to our institute for the cause of her death. We couldn't get any blood samples from MSG's postmortem. (omitted)

  • PDF